{"title":"高血压患者在家测量血压的现状。韩国两个城市的调查结果。","authors":"Kyung-ju Lee MD, Moo-Yong Rhee MD, PhD","doi":"10.1111/jch.14808","DOIUrl":null,"url":null,"abstract":"<p>Knowledge of the status of real-world home blood pressure (BP) measurements is crucial for establishing policies promoting hypertension treatment through home BP monitoring. However, only a few studies have investigated the status of home BP measurements in real-world settings. This study investigated the practice of Korean patients in measuring BP at home. This study recruited participants aged ≥20 years who were taking antihypertensives and conducted a questionnaire-based survey on home BP measurements. Of 701 participants recruited between August 2018 and April 2020, 673 were included in the analysis. Of these, 359 (53.3%) possessed home BP measurement devices. The devices used by 184 (51.3%) participants were validated, 110 (30.6%) were nonvalidated, and 65 (18.1%) had an unknown validation status. Only 18 patients (5.0%) with home BP devices were aware of the validation tests for home BP measurement devices. Of the 673 participants, 278 (41.3%) measured BP at home (77.4% of the patients owned home BP measurement devices). Among them, at least 74 (26.6%) performed proper measurements (at least once a month, at least twice a day or twice at a time, after at least 1 minute of rest, with at least a 1-min interval between each measurement, and 30 min after drinking coffee, exercising, or smoking). In conclusion, our community-based survey in the nonpresentive Korean population revealed a low rate of home BP measurement, a high rate of using nonvalidated devices, and a high rate of inappropriate measurements, suggesting that more efforts toward patient education regarding home BP measurements are needed.</p>","PeriodicalId":50237,"journal":{"name":"Journal of Clinical Hypertension","volume":"26 7","pages":"825-831"},"PeriodicalIF":2.7000,"publicationDate":"2024-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11232443/pdf/","citationCount":"0","resultStr":"{\"title\":\"Status of home blood pressure measurement in treated hypertensive patients. Results of a survey from two cities in Korea\",\"authors\":\"Kyung-ju Lee MD, Moo-Yong Rhee MD, PhD\",\"doi\":\"10.1111/jch.14808\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Knowledge of the status of real-world home blood pressure (BP) measurements is crucial for establishing policies promoting hypertension treatment through home BP monitoring. However, only a few studies have investigated the status of home BP measurements in real-world settings. This study investigated the practice of Korean patients in measuring BP at home. This study recruited participants aged ≥20 years who were taking antihypertensives and conducted a questionnaire-based survey on home BP measurements. Of 701 participants recruited between August 2018 and April 2020, 673 were included in the analysis. Of these, 359 (53.3%) possessed home BP measurement devices. The devices used by 184 (51.3%) participants were validated, 110 (30.6%) were nonvalidated, and 65 (18.1%) had an unknown validation status. Only 18 patients (5.0%) with home BP devices were aware of the validation tests for home BP measurement devices. Of the 673 participants, 278 (41.3%) measured BP at home (77.4% of the patients owned home BP measurement devices). Among them, at least 74 (26.6%) performed proper measurements (at least once a month, at least twice a day or twice at a time, after at least 1 minute of rest, with at least a 1-min interval between each measurement, and 30 min after drinking coffee, exercising, or smoking). In conclusion, our community-based survey in the nonpresentive Korean population revealed a low rate of home BP measurement, a high rate of using nonvalidated devices, and a high rate of inappropriate measurements, suggesting that more efforts toward patient education regarding home BP measurements are needed.</p>\",\"PeriodicalId\":50237,\"journal\":{\"name\":\"Journal of Clinical Hypertension\",\"volume\":\"26 7\",\"pages\":\"825-831\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-06-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11232443/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Hypertension\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/jch.14808\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Hypertension","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jch.14808","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
Status of home blood pressure measurement in treated hypertensive patients. Results of a survey from two cities in Korea
Knowledge of the status of real-world home blood pressure (BP) measurements is crucial for establishing policies promoting hypertension treatment through home BP monitoring. However, only a few studies have investigated the status of home BP measurements in real-world settings. This study investigated the practice of Korean patients in measuring BP at home. This study recruited participants aged ≥20 years who were taking antihypertensives and conducted a questionnaire-based survey on home BP measurements. Of 701 participants recruited between August 2018 and April 2020, 673 were included in the analysis. Of these, 359 (53.3%) possessed home BP measurement devices. The devices used by 184 (51.3%) participants were validated, 110 (30.6%) were nonvalidated, and 65 (18.1%) had an unknown validation status. Only 18 patients (5.0%) with home BP devices were aware of the validation tests for home BP measurement devices. Of the 673 participants, 278 (41.3%) measured BP at home (77.4% of the patients owned home BP measurement devices). Among them, at least 74 (26.6%) performed proper measurements (at least once a month, at least twice a day or twice at a time, after at least 1 minute of rest, with at least a 1-min interval between each measurement, and 30 min after drinking coffee, exercising, or smoking). In conclusion, our community-based survey in the nonpresentive Korean population revealed a low rate of home BP measurement, a high rate of using nonvalidated devices, and a high rate of inappropriate measurements, suggesting that more efforts toward patient education regarding home BP measurements are needed.
期刊介绍:
The Journal of Clinical Hypertension is a peer-reviewed, monthly publication that serves internists, cardiologists, nephrologists, endocrinologists, hypertension specialists, primary care practitioners, pharmacists and all professionals interested in hypertension by providing objective, up-to-date information and practical recommendations on the full range of clinical aspects of hypertension. Commentaries and columns by experts in the field provide further insights into our original research articles as well as on major articles published elsewhere. Major guidelines for the management of hypertension are also an important feature of the Journal. Through its partnership with the World Hypertension League, JCH will include a new focus on hypertension and public health, including major policy issues, that features research and reviews related to disease characteristics and management at the population level.