视神经 T2 信号强度和直径反映遗传性视神经萎缩的临床严重程度

IF 2 4区 医学 Q3 CLINICAL NEUROLOGY
Journal of Neuro-Ophthalmology Pub Date : 2025-06-01 Epub Date: 2024-06-17 DOI:10.1097/WNO.0000000000002191
M Aurel Nagy, Mary E Cunnane, Amy F Juliano, Janey L Wiggs, Paul A Caruso, Eric D Gaier
{"title":"视神经 T2 信号强度和直径反映遗传性视神经萎缩的临床严重程度","authors":"M Aurel Nagy, Mary E Cunnane, Amy F Juliano, Janey L Wiggs, Paul A Caruso, Eric D Gaier","doi":"10.1097/WNO.0000000000002191","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Genetic optic atrophies comprise phenotypically heterogenous disorders of mitochondrial function. We aimed to correlate quantitative neuroimaging findings of the optic nerves in these disorders with clinical measures.</p><p><strong>Methods: </strong>From a retrospective database of 111 patients with bilateral optic atrophy referred for genetic testing, 15 patients diagnosed with nonglaucomatous optic atrophy of genetic origin (7 patients with pathogenic variants in OPA1 , 3 patients with Wolfram syndrome, and 5 patients with Leber hereditary optic neuropathy) who had accessible magnetic resonance (MR) images of the orbits and/or brain were analyzed. The primary outcome measures of T2 short Tau inversion recovery (STIR) signal and optic nerve caliber were quantified according to a standardized protocol, normalized to internal standards, and compared between cases and controls. Inter-rater reliability was assessed and clinical features were analyzed according to MRI features.</p><p><strong>Results: </strong>Compared with control patients, the 15 genetic optic atrophy patients demonstrated significantly increased T2 STIR signal (fold-change 1.6, P = 0.0016) and decreased optic nerve caliber (fold-change 0.72, P = 0.00012) after internal normalization. These metrics were reliable (inter-reader reliability correlation coefficients of 0.98 [ P = 0.00036] and 0.74 [ P = 0.0025] for normalized STIR and nerve caliber, respectively) and significantly correlated with visual acuity, cup-to-disc ratio, and visual field testing.</p><p><strong>Conclusions: </strong>Normalized optic nerve STIR signal and optic nerve caliber significantly correlate with visual acuity, cup-to-disc ratio, and perimetric performance in patients with genetic optic atrophy. A formalized protocol to characterize these differences on MRI may help to guide accurate and expedient diagnostic evaluation.</p>","PeriodicalId":16485,"journal":{"name":"Journal of Neuro-Ophthalmology","volume":" ","pages":"145-152"},"PeriodicalIF":2.0000,"publicationDate":"2025-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11649859/pdf/","citationCount":"0","resultStr":"{\"title\":\"Optic Nerve T2 Signal Intensity and Caliber Reflect Clinical Severity in Genetic Optic Atrophy.\",\"authors\":\"M Aurel Nagy, Mary E Cunnane, Amy F Juliano, Janey L Wiggs, Paul A Caruso, Eric D Gaier\",\"doi\":\"10.1097/WNO.0000000000002191\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Genetic optic atrophies comprise phenotypically heterogenous disorders of mitochondrial function. We aimed to correlate quantitative neuroimaging findings of the optic nerves in these disorders with clinical measures.</p><p><strong>Methods: </strong>From a retrospective database of 111 patients with bilateral optic atrophy referred for genetic testing, 15 patients diagnosed with nonglaucomatous optic atrophy of genetic origin (7 patients with pathogenic variants in OPA1 , 3 patients with Wolfram syndrome, and 5 patients with Leber hereditary optic neuropathy) who had accessible magnetic resonance (MR) images of the orbits and/or brain were analyzed. The primary outcome measures of T2 short Tau inversion recovery (STIR) signal and optic nerve caliber were quantified according to a standardized protocol, normalized to internal standards, and compared between cases and controls. Inter-rater reliability was assessed and clinical features were analyzed according to MRI features.</p><p><strong>Results: </strong>Compared with control patients, the 15 genetic optic atrophy patients demonstrated significantly increased T2 STIR signal (fold-change 1.6, P = 0.0016) and decreased optic nerve caliber (fold-change 0.72, P = 0.00012) after internal normalization. These metrics were reliable (inter-reader reliability correlation coefficients of 0.98 [ P = 0.00036] and 0.74 [ P = 0.0025] for normalized STIR and nerve caliber, respectively) and significantly correlated with visual acuity, cup-to-disc ratio, and visual field testing.</p><p><strong>Conclusions: </strong>Normalized optic nerve STIR signal and optic nerve caliber significantly correlate with visual acuity, cup-to-disc ratio, and perimetric performance in patients with genetic optic atrophy. A formalized protocol to characterize these differences on MRI may help to guide accurate and expedient diagnostic evaluation.</p>\",\"PeriodicalId\":16485,\"journal\":{\"name\":\"Journal of Neuro-Ophthalmology\",\"volume\":\" \",\"pages\":\"145-152\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2025-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11649859/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Neuro-Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/WNO.0000000000002191\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Neuro-Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/WNO.0000000000002191","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/17 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:遗传性视神经萎缩包括表型异质性的线粒体功能紊乱。我们的目的是将这些疾病的视神经定量神经成像结果与临床测量结果进行关联分析:方法:我们从一个回顾性数据库中收集了111名转诊接受基因检测的双侧视神经萎缩患者,并对其中15名被诊断为非白斑性视神经萎缩的遗传性患者(7名OPA1致病变异患者、3名Wolfram综合征患者和5名Leber遗传性视神经病变患者)的眼眶和/或大脑磁共振(MR)图像进行了分析。根据标准化方案对 T2 短陶反转恢复(STIR)信号和视神经口径的主要结果指标进行量化,归一化为内部标准,并在病例和对照组之间进行比较。结果显示,与对照组患者相比,15 例遗传病患者的视力均有不同程度的下降:结果:与对照组患者相比,15 例遗传性视神经萎缩患者的 T2 STIR 信号明显增加(折变 1.6,P = 0.0016),内部归一化后视神经口径减小(折变 0.72,P = 0.00012)。这些指标是可靠的(正常化 STIR 和神经口径的读片者间可靠性相关系数分别为 0.98 [P = 0.00036] 和 0.74 [P = 0.0025]),并且与视力、杯盘比和视野测试显著相关:结论:正常化视神经 STIR 信号和视神经口径与遗传性视神经萎缩患者的视敏度、杯盘比和周边视力有明显相关性。在磁共振成像上描述这些差异的正式方案可能有助于指导准确、快速的诊断评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optic Nerve T2 Signal Intensity and Caliber Reflect Clinical Severity in Genetic Optic Atrophy.

Background: Genetic optic atrophies comprise phenotypically heterogenous disorders of mitochondrial function. We aimed to correlate quantitative neuroimaging findings of the optic nerves in these disorders with clinical measures.

Methods: From a retrospective database of 111 patients with bilateral optic atrophy referred for genetic testing, 15 patients diagnosed with nonglaucomatous optic atrophy of genetic origin (7 patients with pathogenic variants in OPA1 , 3 patients with Wolfram syndrome, and 5 patients with Leber hereditary optic neuropathy) who had accessible magnetic resonance (MR) images of the orbits and/or brain were analyzed. The primary outcome measures of T2 short Tau inversion recovery (STIR) signal and optic nerve caliber were quantified according to a standardized protocol, normalized to internal standards, and compared between cases and controls. Inter-rater reliability was assessed and clinical features were analyzed according to MRI features.

Results: Compared with control patients, the 15 genetic optic atrophy patients demonstrated significantly increased T2 STIR signal (fold-change 1.6, P = 0.0016) and decreased optic nerve caliber (fold-change 0.72, P = 0.00012) after internal normalization. These metrics were reliable (inter-reader reliability correlation coefficients of 0.98 [ P = 0.00036] and 0.74 [ P = 0.0025] for normalized STIR and nerve caliber, respectively) and significantly correlated with visual acuity, cup-to-disc ratio, and visual field testing.

Conclusions: Normalized optic nerve STIR signal and optic nerve caliber significantly correlate with visual acuity, cup-to-disc ratio, and perimetric performance in patients with genetic optic atrophy. A formalized protocol to characterize these differences on MRI may help to guide accurate and expedient diagnostic evaluation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Neuro-Ophthalmology
Journal of Neuro-Ophthalmology 医学-临床神经学
CiteScore
2.80
自引率
13.80%
发文量
593
审稿时长
6-12 weeks
期刊介绍: The Journal of Neuro-Ophthalmology (JNO) is the official journal of the North American Neuro-Ophthalmology Society (NANOS). It is a quarterly, peer-reviewed journal that publishes original and commissioned articles related to neuro-ophthalmology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信