全身性异维A酸治疗对泪膜、睑板腺和角膜内皮的影响。

IF 1.6 4区 医学 Q3 OPHTHALMOLOGY
Cutaneous and Ocular Toxicology Pub Date : 2024-09-01 Epub Date: 2024-06-14 DOI:10.1080/15569527.2024.2366856
Kamile Demir, Feyzahan Uzun
{"title":"全身性异维A酸治疗对泪膜、睑板腺和角膜内皮的影响。","authors":"Kamile Demir, Feyzahan Uzun","doi":"10.1080/15569527.2024.2366856","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The study aims to investigate changes in tear function, meibomian glands and corneal endothelium in patients receiving systemic isotretinoin therapy.</p><p><strong>Materials and methods: </strong>This prospective study included 38 eyes from 38 patients (23 females and 15 males) treated with systemic isotretinoin (0.5-1 mg/kg/day) following the diagnosis of acne vulgaris. All patients underwent a comprehensive ophthalmologic examination at baseline, 1st month, and third month of treatment. Subjective complaints were assessed using the Ocular Surface Disease Index (OSDI). Tear functions were evaluated through non-invasive tear break up time (NIBUT) and Schirmer I test. Meibomian gland (MG) changes were examined using meibography. Corneal parameters, including endothelial cell density (ECD), coefficient of variation (CV), the number of cells with a hexagonal shape (6A), average cell area (AVG), and central corneal thickness (CCT) were assessed using non-contact specular microscopy.</p><p><strong>Results: </strong>The mean age of the patients was 19.29 ± 2.83 years. Ocular surface-related discomfort, measured with OSDI scores, significantly worsened at the third month measurements compared to the pre-treatment values (<i>p</i> < 0.001). In the 1st month of treatment, there was a significant decrease in NIBUT (<i>p</i> < 0.05). No statistically significant difference was found in the Schirmer test results at each visit. According to the 1st and third-month analysis, there was a significant increase in MG loss compared to the pre-treatment period (<i>p</i> < 0.001). ECD, CV, 6 A, AVG measurements at the first and third months showed a significant change compared to the pre-treatment values (<i>p</i> < 0.001). No significant difference was observed in the CCT measurements during the treatment.</p><p><strong>Conclusion: </strong>Systemic isotretinoin disrupted tear stability, caused MG loss, deterioration in corneal endothelium, and led to symptomatic complaints in patients.</p>","PeriodicalId":11023,"journal":{"name":"Cutaneous and Ocular Toxicology","volume":" ","pages":"176-181"},"PeriodicalIF":1.6000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The impact of systemic isotretinoin treatment on the tear film, meibomian glands, and corneal endothelium.\",\"authors\":\"Kamile Demir, Feyzahan Uzun\",\"doi\":\"10.1080/15569527.2024.2366856\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The study aims to investigate changes in tear function, meibomian glands and corneal endothelium in patients receiving systemic isotretinoin therapy.</p><p><strong>Materials and methods: </strong>This prospective study included 38 eyes from 38 patients (23 females and 15 males) treated with systemic isotretinoin (0.5-1 mg/kg/day) following the diagnosis of acne vulgaris. All patients underwent a comprehensive ophthalmologic examination at baseline, 1st month, and third month of treatment. Subjective complaints were assessed using the Ocular Surface Disease Index (OSDI). Tear functions were evaluated through non-invasive tear break up time (NIBUT) and Schirmer I test. Meibomian gland (MG) changes were examined using meibography. Corneal parameters, including endothelial cell density (ECD), coefficient of variation (CV), the number of cells with a hexagonal shape (6A), average cell area (AVG), and central corneal thickness (CCT) were assessed using non-contact specular microscopy.</p><p><strong>Results: </strong>The mean age of the patients was 19.29 ± 2.83 years. Ocular surface-related discomfort, measured with OSDI scores, significantly worsened at the third month measurements compared to the pre-treatment values (<i>p</i> < 0.001). In the 1st month of treatment, there was a significant decrease in NIBUT (<i>p</i> < 0.05). No statistically significant difference was found in the Schirmer test results at each visit. According to the 1st and third-month analysis, there was a significant increase in MG loss compared to the pre-treatment period (<i>p</i> < 0.001). ECD, CV, 6 A, AVG measurements at the first and third months showed a significant change compared to the pre-treatment values (<i>p</i> < 0.001). No significant difference was observed in the CCT measurements during the treatment.</p><p><strong>Conclusion: </strong>Systemic isotretinoin disrupted tear stability, caused MG loss, deterioration in corneal endothelium, and led to symptomatic complaints in patients.</p>\",\"PeriodicalId\":11023,\"journal\":{\"name\":\"Cutaneous and Ocular Toxicology\",\"volume\":\" \",\"pages\":\"176-181\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cutaneous and Ocular Toxicology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/15569527.2024.2366856\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cutaneous and Ocular Toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/15569527.2024.2366856","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/14 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在调查接受全身性异维A酸治疗的患者泪液功能、睑板腺和角膜内皮的变化:这项前瞻性研究纳入了 38 名患者(23 名女性和 15 名男性)的 38 只眼睛,这些患者在确诊为寻常型痤疮后接受了系统性异维A酸治疗(0.5-1 毫克/千克/天)。所有患者均在基线期、治疗第一个月和第三个月接受了全面的眼科检查。采用眼表疾病指数(OSDI)对主观症状进行评估。泪液功能通过无创泪液破裂时间(NIBUT)和Schirmer I测试进行评估。使用meibography检查睑板腺(MG)的变化。角膜参数包括内皮细胞密度(ECD)、变异系数(CV)、六角形细胞数量(6A)、平均细胞面积(AVG)和角膜中央厚度(CCT),采用非接触式镜面显微镜进行评估:患者的平均年龄为(19.29 ± 2.83)岁。与治疗前相比,用OSDI评分测量的眼表相关不适感在第三个月的测量中明显加重(p p p p 结论):全身使用异维A酸会破坏泪液的稳定性,导致MG流失、角膜内皮细胞退化,并导致患者出现症状性不适。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The impact of systemic isotretinoin treatment on the tear film, meibomian glands, and corneal endothelium.

Purpose: The study aims to investigate changes in tear function, meibomian glands and corneal endothelium in patients receiving systemic isotretinoin therapy.

Materials and methods: This prospective study included 38 eyes from 38 patients (23 females and 15 males) treated with systemic isotretinoin (0.5-1 mg/kg/day) following the diagnosis of acne vulgaris. All patients underwent a comprehensive ophthalmologic examination at baseline, 1st month, and third month of treatment. Subjective complaints were assessed using the Ocular Surface Disease Index (OSDI). Tear functions were evaluated through non-invasive tear break up time (NIBUT) and Schirmer I test. Meibomian gland (MG) changes were examined using meibography. Corneal parameters, including endothelial cell density (ECD), coefficient of variation (CV), the number of cells with a hexagonal shape (6A), average cell area (AVG), and central corneal thickness (CCT) were assessed using non-contact specular microscopy.

Results: The mean age of the patients was 19.29 ± 2.83 years. Ocular surface-related discomfort, measured with OSDI scores, significantly worsened at the third month measurements compared to the pre-treatment values (p < 0.001). In the 1st month of treatment, there was a significant decrease in NIBUT (p < 0.05). No statistically significant difference was found in the Schirmer test results at each visit. According to the 1st and third-month analysis, there was a significant increase in MG loss compared to the pre-treatment period (p < 0.001). ECD, CV, 6 A, AVG measurements at the first and third months showed a significant change compared to the pre-treatment values (p < 0.001). No significant difference was observed in the CCT measurements during the treatment.

Conclusion: Systemic isotretinoin disrupted tear stability, caused MG loss, deterioration in corneal endothelium, and led to symptomatic complaints in patients.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.30
自引率
6.20%
发文量
40
审稿时长
1 months
期刊介绍: Cutaneous and Ocular Toxicology is an international, peer-reviewed journal that covers all types of harm to cutaneous and ocular systems. Areas of particular interest include pharmaceutical and medical products; consumer, personal care, and household products; and issues in environmental and occupational exposures. In addition to original research papers, reviews and short communications are invited, as well as concise, relevant, and critical reviews of topics of contemporary significance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信