评估用于检测甲状腺结节细针抽吸标本中 BRAF V600E 的液滴数字 PCR。

IF 4 2区 医学 Q1 MEDICAL LABORATORY TECHNOLOGY
Annals of Laboratory Medicine Pub Date : 2024-11-01 Epub Date: 2024-06-14 DOI:10.3343/alm.2023.0405
Young Kyu Min, Jae Kyung Kim, Kyung Sun Park, Jong-Won Kim
{"title":"评估用于检测甲状腺结节细针抽吸标本中 BRAF V600E 的液滴数字 PCR。","authors":"Young Kyu Min, Jae Kyung Kim, Kyung Sun Park, Jong-Won Kim","doi":"10.3343/alm.2023.0405","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Droplet digital (dd)PCR is a new-generation PCR technique with high precision and sensitivity; however, the positive and negative droplets are not always effectively separated because of the \"rain\" phenomenon. We aimed to develop a practical optimization and evaluation process for the ddPCR assay and to apply it to the detection of <i>BRAF</i> V600E in fine-needle aspiration (FNA) specimens of thyroid nodules, as an example.</p><p><strong>Methods: </strong>We optimized seven ddPCR parameters that can affect \"rain.\" Analytical and clinical performance were analyzed based on histological diagnosis after thyroidectomy using a consecutive prospective series of 242 FNA specimens.</p><p><strong>Results: </strong>The annealing time and temperature, number of PCR cycles, and primer and probe concentrations were found to be more important considerations for assay optimization than the denaturation time and ramp rate. The limit of blank and 95% limit of detection were 0% and 0.027%, respectively. The sensitivity of ddPCR for histological papillary thyroid carcinoma (PTC) was 82.4% (95% confidence interval [CI], 73.6%-89.2%). The pooled sensitivity of <i>BRAF</i> V600E in FNA specimens for histological PTC was 78.6% (95% CI, 75.9%-81.2%, I<sup>2</sup>=60.6%).</p><p><strong>Conclusions: </strong>We present a practical approach for optimizing ddPCR parameters that affect the separation of positive and negative droplets to reduce rain. Our approach to optimizing ddPCR parameters can be expanded to general ddPCR assays for specific mutations in clinical laboratories. The highly sensitive ddPCR can compensate for uncertainty in cytological diagnosis by detecting low levels of <i>BRAF</i> V600E.</p>","PeriodicalId":8421,"journal":{"name":"Annals of Laboratory Medicine","volume":" ","pages":"553-561"},"PeriodicalIF":4.0000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11375207/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Droplet Digital PCR for the Detection of <i>BRAF</i> V600E in Fine-Needle Aspiration Specimens of Thyroid Nodules.\",\"authors\":\"Young Kyu Min, Jae Kyung Kim, Kyung Sun Park, Jong-Won Kim\",\"doi\":\"10.3343/alm.2023.0405\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Droplet digital (dd)PCR is a new-generation PCR technique with high precision and sensitivity; however, the positive and negative droplets are not always effectively separated because of the \\\"rain\\\" phenomenon. We aimed to develop a practical optimization and evaluation process for the ddPCR assay and to apply it to the detection of <i>BRAF</i> V600E in fine-needle aspiration (FNA) specimens of thyroid nodules, as an example.</p><p><strong>Methods: </strong>We optimized seven ddPCR parameters that can affect \\\"rain.\\\" Analytical and clinical performance were analyzed based on histological diagnosis after thyroidectomy using a consecutive prospective series of 242 FNA specimens.</p><p><strong>Results: </strong>The annealing time and temperature, number of PCR cycles, and primer and probe concentrations were found to be more important considerations for assay optimization than the denaturation time and ramp rate. The limit of blank and 95% limit of detection were 0% and 0.027%, respectively. The sensitivity of ddPCR for histological papillary thyroid carcinoma (PTC) was 82.4% (95% confidence interval [CI], 73.6%-89.2%). The pooled sensitivity of <i>BRAF</i> V600E in FNA specimens for histological PTC was 78.6% (95% CI, 75.9%-81.2%, I<sup>2</sup>=60.6%).</p><p><strong>Conclusions: </strong>We present a practical approach for optimizing ddPCR parameters that affect the separation of positive and negative droplets to reduce rain. Our approach to optimizing ddPCR parameters can be expanded to general ddPCR assays for specific mutations in clinical laboratories. The highly sensitive ddPCR can compensate for uncertainty in cytological diagnosis by detecting low levels of <i>BRAF</i> V600E.</p>\",\"PeriodicalId\":8421,\"journal\":{\"name\":\"Annals of Laboratory Medicine\",\"volume\":\" \",\"pages\":\"553-561\"},\"PeriodicalIF\":4.0000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11375207/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Laboratory Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3343/alm.2023.0405\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Laboratory Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3343/alm.2023.0405","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/14 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:液滴数字(dd)PCR是新一代PCR技术,具有高精度和高灵敏度;然而,由于 "雨 "现象,阳性液滴和阴性液滴并不总能有效分离。我们旨在为 ddPCR 检测开发一套实用的优化和评估流程,并将其应用于甲状腺结节细针穿刺(FNA)标本中 BRAF V600E 的检测:方法:我们对可能影响 "雨 "的七个 ddPCR 参数进行了优化。结果发现,退火时间和温度、PCR 循环次数、引物和探针浓度比变性时间和斜率对检测优化更为重要。空白限和 95% 检测限分别为 0% 和 0.027%。ddPCR 对组织学甲状腺乳头状癌 (PTC) 的灵敏度为 82.4%(95% 置信区间 [CI],73.6%-89.2%)。FNA 标本中 BRAF V600E 对组织学 PTC 的汇总灵敏度为 78.6%(95% CI,75.9%-81.2%,I2=60.6%):我们介绍了一种优化 ddPCR 参数的实用方法,这些参数会影响阳性液滴和阴性液滴的分离,从而减少雨滴。我们的 ddPCR 参数优化方法可扩展到临床实验室中针对特定突变的一般 ddPCR 检测。高灵敏度的 ddPCR 可以通过检测低水平的 BRAF V600E 来弥补细胞学诊断的不确定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of Droplet Digital PCR for the Detection of BRAF V600E in Fine-Needle Aspiration Specimens of Thyroid Nodules.

Background: Droplet digital (dd)PCR is a new-generation PCR technique with high precision and sensitivity; however, the positive and negative droplets are not always effectively separated because of the "rain" phenomenon. We aimed to develop a practical optimization and evaluation process for the ddPCR assay and to apply it to the detection of BRAF V600E in fine-needle aspiration (FNA) specimens of thyroid nodules, as an example.

Methods: We optimized seven ddPCR parameters that can affect "rain." Analytical and clinical performance were analyzed based on histological diagnosis after thyroidectomy using a consecutive prospective series of 242 FNA specimens.

Results: The annealing time and temperature, number of PCR cycles, and primer and probe concentrations were found to be more important considerations for assay optimization than the denaturation time and ramp rate. The limit of blank and 95% limit of detection were 0% and 0.027%, respectively. The sensitivity of ddPCR for histological papillary thyroid carcinoma (PTC) was 82.4% (95% confidence interval [CI], 73.6%-89.2%). The pooled sensitivity of BRAF V600E in FNA specimens for histological PTC was 78.6% (95% CI, 75.9%-81.2%, I2=60.6%).

Conclusions: We present a practical approach for optimizing ddPCR parameters that affect the separation of positive and negative droplets to reduce rain. Our approach to optimizing ddPCR parameters can be expanded to general ddPCR assays for specific mutations in clinical laboratories. The highly sensitive ddPCR can compensate for uncertainty in cytological diagnosis by detecting low levels of BRAF V600E.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Annals of Laboratory Medicine
Annals of Laboratory Medicine MEDICAL LABORATORY TECHNOLOGY-
CiteScore
8.30
自引率
12.20%
发文量
100
审稿时长
6-12 weeks
期刊介绍: Annals of Laboratory Medicine is the official journal of Korean Society for Laboratory Medicine. The journal title has been recently changed from the Korean Journal of Laboratory Medicine (ISSN, 1598-6535) from the January issue of 2012. The JCR 2017 Impact factor of Ann Lab Med was 1.916.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信