Owen P Leary, Zhusi Zhong, Lulu Bi, Zhicheng Jiao, Yu-Wei Dai, Kevin Ma, Shanzeh Sayied, Daniel Kargilis, Maliha Imami, Lin-Mei Zhao, Xue Feng, Gerald Riccardello, Scott Collins, Konstantina Svokos, Abhay Moghekar, Li Yang, Harrison Bai, Petra M Klinge, Jerrold L Boxerman
{"title":"基于磁共振成像的正常压力脑积水(NPH)脑室分流术后临床改善预测:综合多序列机器学习算法的开发与评估》。","authors":"Owen P Leary, Zhusi Zhong, Lulu Bi, Zhicheng Jiao, Yu-Wei Dai, Kevin Ma, Shanzeh Sayied, Daniel Kargilis, Maliha Imami, Lin-Mei Zhao, Xue Feng, Gerald Riccardello, Scott Collins, Konstantina Svokos, Abhay Moghekar, Li Yang, Harrison Bai, Petra M Klinge, Jerrold L Boxerman","doi":"10.3174/ajnr.A8372","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and purpose: </strong>Symptoms of normal pressure hydrocephalus (NPH) are sometimes refractory to shunt placement, with limited ability to predict improvement for individual patients. We evaluated an MRI-based artificial intelligence method to predict postshunt NPH symptom improvement.</p><p><strong>Materials and methods: </strong>Patients with NPH who underwent MRI before shunt placement at a single center (2014-2021) were identified. Twelve-month postshunt improvement in mRS, incontinence, gait, and cognition were retrospectively abstracted from clinical documentation. 3D deep residual neural networks were built on skull-stripped T2-weighted and FLAIR images. Predictions based on both sequences were fused by additional network layers. Patients from 2014-2019 were used for parameter optimization, while those from 2020-2021 were used for testing. Models were validated on an external validation data set from a second institution (<i>n</i> = 33).</p><p><strong>Results: </strong>Of 249 patients, <i>n</i> = 201 and <i>n</i> = 185 were included in the T2-based and FLAIR-based models according to imaging availability. The combination of T2-weighted and FLAIR sequences offered the best performance in mRS and gait improvement predictions relative to models trained on imaging acquired by using only 1 sequence, with area under the receiver operating characteristic (AUROC) values of 0.7395 [0.5765-0.9024] for mRS and 0.8816 [0.8030-0.9602] for gait. For urinary incontinence and cognition, combined model performances on predicting outcomes were similar to FLAIR-only performance, with AUROC values of 0.7874 [0.6845-0.8903] and 0.7230 [0.5600-0.8859].</p><p><strong>Conclusions: </strong>Application of a combined algorithm by using both T2-weighted and FLAIR sequences offered the best image-based prediction of postshunt symptom improvement, particularly for gait and overall function in terms of mRS.</p>","PeriodicalId":93863,"journal":{"name":"AJNR. American journal of neuroradiology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11448992/pdf/","citationCount":"0","resultStr":"{\"title\":\"MRI-Based Prediction of Clinical Improvement after Ventricular Shunt Placement for Normal Pressure Hydrocephalus: Development and Evaluation of an Integrated Multisequence Machine Learning Algorithm.\",\"authors\":\"Owen P Leary, Zhusi Zhong, Lulu Bi, Zhicheng Jiao, Yu-Wei Dai, Kevin Ma, Shanzeh Sayied, Daniel Kargilis, Maliha Imami, Lin-Mei Zhao, Xue Feng, Gerald Riccardello, Scott Collins, Konstantina Svokos, Abhay Moghekar, Li Yang, Harrison Bai, Petra M Klinge, Jerrold L Boxerman\",\"doi\":\"10.3174/ajnr.A8372\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and purpose: </strong>Symptoms of normal pressure hydrocephalus (NPH) are sometimes refractory to shunt placement, with limited ability to predict improvement for individual patients. We evaluated an MRI-based artificial intelligence method to predict postshunt NPH symptom improvement.</p><p><strong>Materials and methods: </strong>Patients with NPH who underwent MRI before shunt placement at a single center (2014-2021) were identified. Twelve-month postshunt improvement in mRS, incontinence, gait, and cognition were retrospectively abstracted from clinical documentation. 3D deep residual neural networks were built on skull-stripped T2-weighted and FLAIR images. Predictions based on both sequences were fused by additional network layers. Patients from 2014-2019 were used for parameter optimization, while those from 2020-2021 were used for testing. Models were validated on an external validation data set from a second institution (<i>n</i> = 33).</p><p><strong>Results: </strong>Of 249 patients, <i>n</i> = 201 and <i>n</i> = 185 were included in the T2-based and FLAIR-based models according to imaging availability. The combination of T2-weighted and FLAIR sequences offered the best performance in mRS and gait improvement predictions relative to models trained on imaging acquired by using only 1 sequence, with area under the receiver operating characteristic (AUROC) values of 0.7395 [0.5765-0.9024] for mRS and 0.8816 [0.8030-0.9602] for gait. For urinary incontinence and cognition, combined model performances on predicting outcomes were similar to FLAIR-only performance, with AUROC values of 0.7874 [0.6845-0.8903] and 0.7230 [0.5600-0.8859].</p><p><strong>Conclusions: </strong>Application of a combined algorithm by using both T2-weighted and FLAIR sequences offered the best image-based prediction of postshunt symptom improvement, particularly for gait and overall function in terms of mRS.</p>\",\"PeriodicalId\":93863,\"journal\":{\"name\":\"AJNR. American journal of neuroradiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-10-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11448992/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"AJNR. American journal of neuroradiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3174/ajnr.A8372\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"AJNR. American journal of neuroradiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3174/ajnr.A8372","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
MRI-Based Prediction of Clinical Improvement after Ventricular Shunt Placement for Normal Pressure Hydrocephalus: Development and Evaluation of an Integrated Multisequence Machine Learning Algorithm.
Background and purpose: Symptoms of normal pressure hydrocephalus (NPH) are sometimes refractory to shunt placement, with limited ability to predict improvement for individual patients. We evaluated an MRI-based artificial intelligence method to predict postshunt NPH symptom improvement.
Materials and methods: Patients with NPH who underwent MRI before shunt placement at a single center (2014-2021) were identified. Twelve-month postshunt improvement in mRS, incontinence, gait, and cognition were retrospectively abstracted from clinical documentation. 3D deep residual neural networks were built on skull-stripped T2-weighted and FLAIR images. Predictions based on both sequences were fused by additional network layers. Patients from 2014-2019 were used for parameter optimization, while those from 2020-2021 were used for testing. Models were validated on an external validation data set from a second institution (n = 33).
Results: Of 249 patients, n = 201 and n = 185 were included in the T2-based and FLAIR-based models according to imaging availability. The combination of T2-weighted and FLAIR sequences offered the best performance in mRS and gait improvement predictions relative to models trained on imaging acquired by using only 1 sequence, with area under the receiver operating characteristic (AUROC) values of 0.7395 [0.5765-0.9024] for mRS and 0.8816 [0.8030-0.9602] for gait. For urinary incontinence and cognition, combined model performances on predicting outcomes were similar to FLAIR-only performance, with AUROC values of 0.7874 [0.6845-0.8903] and 0.7230 [0.5600-0.8859].
Conclusions: Application of a combined algorithm by using both T2-weighted and FLAIR sequences offered the best image-based prediction of postshunt symptom improvement, particularly for gait and overall function in terms of mRS.