Roberto Sorrentino, Gennaro Ruggiero, Renato Leone, Maria Irene Di Mauro, Edoardo Ferrari Cagidiaco, Tim Joda, Lucio Lo Russo, Fernando Zarone
{"title":"不同腭部形态对无牙上颌骨口内扫描准确性的影响:三维分析。","authors":"Roberto Sorrentino, Gennaro Ruggiero, Renato Leone, Maria Irene Di Mauro, Edoardo Ferrari Cagidiaco, Tim Joda, Lucio Lo Russo, Fernando Zarone","doi":"10.2186/jpr.JPR_D_23_00175","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study investigated the influence of different palatal morphologies on the accuracy of intraoral scanning (TRIOS 4) of edentulous maxillae.</p><p><strong>Methods: </strong>Six typodonts were fabricated for different palatal morphologies with flat (F), medium (M), and deep (D) palates, with palatal wrinkles (W), or smooth palates (S), resulting in six groups: WF, WM, WD and SF, SM, SD. Ten scans were performed for each group; standard tessellation language files obtained were imported into a software to measure trueness and precision in micrometer. Trueness was calculated as the mean of the standard deviation values obtained by superimposing each scan onto the reference scan. Precision was achieved by overlapping each scan with that with the best trueness in the group. Descriptive and post-hoc analyses were conducted.</p><p><strong>Results: </strong>The mean values for trueness were as follows: WM=48.7±4.7, WD=161.7±18.4, WF=85.9±16, SM=48.1±2.4, SD=349.9±8.8, and SF=349.1±25.5. The precision values were as follows: WM=46.7±7.3, WD=46.9±9, WF=48.9±6.7, SM=46±2.7, SD=105.9±17.4, SF=72.6±10.8. Significant differences were observed for trueness between SM and SD (P < 0.001), SM and SF (P < 0.001), and WF and SF (P = 0.003); whereas for precision, significant differences were reported between WD and SD (P = 0.015). Regarding trueness and precision, no difference was found between WM and SM (P = 1.0).</p><p><strong>Conclusions: </strong>Medium palatal depth showed the best accuracy. The mean accuracy values were within the clinical acceptability thresholds for all palatal morphologies. The presence of rugae improved the precision of deeper palates and the trueness of flat palates. No differences were observed in the medium palates with or without rugae.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of different palatal morphologies on the accuracy of intraoral scanning of the edentulous maxilla: A three-dimensional analysis.\",\"authors\":\"Roberto Sorrentino, Gennaro Ruggiero, Renato Leone, Maria Irene Di Mauro, Edoardo Ferrari Cagidiaco, Tim Joda, Lucio Lo Russo, Fernando Zarone\",\"doi\":\"10.2186/jpr.JPR_D_23_00175\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study investigated the influence of different palatal morphologies on the accuracy of intraoral scanning (TRIOS 4) of edentulous maxillae.</p><p><strong>Methods: </strong>Six typodonts were fabricated for different palatal morphologies with flat (F), medium (M), and deep (D) palates, with palatal wrinkles (W), or smooth palates (S), resulting in six groups: WF, WM, WD and SF, SM, SD. Ten scans were performed for each group; standard tessellation language files obtained were imported into a software to measure trueness and precision in micrometer. Trueness was calculated as the mean of the standard deviation values obtained by superimposing each scan onto the reference scan. Precision was achieved by overlapping each scan with that with the best trueness in the group. Descriptive and post-hoc analyses were conducted.</p><p><strong>Results: </strong>The mean values for trueness were as follows: WM=48.7±4.7, WD=161.7±18.4, WF=85.9±16, SM=48.1±2.4, SD=349.9±8.8, and SF=349.1±25.5. The precision values were as follows: WM=46.7±7.3, WD=46.9±9, WF=48.9±6.7, SM=46±2.7, SD=105.9±17.4, SF=72.6±10.8. Significant differences were observed for trueness between SM and SD (P < 0.001), SM and SF (P < 0.001), and WF and SF (P = 0.003); whereas for precision, significant differences were reported between WD and SD (P = 0.015). Regarding trueness and precision, no difference was found between WM and SM (P = 1.0).</p><p><strong>Conclusions: </strong>Medium palatal depth showed the best accuracy. The mean accuracy values were within the clinical acceptability thresholds for all palatal morphologies. The presence of rugae improved the precision of deeper palates and the trueness of flat palates. No differences were observed in the medium palates with or without rugae.</p>\",\"PeriodicalId\":3,\"journal\":{\"name\":\"ACS Applied Electronic Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-10-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Electronic Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2186/jpr.JPR_D_23_00175\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/12 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2186/jpr.JPR_D_23_00175","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/12 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Influence of different palatal morphologies on the accuracy of intraoral scanning of the edentulous maxilla: A three-dimensional analysis.
Purpose: This study investigated the influence of different palatal morphologies on the accuracy of intraoral scanning (TRIOS 4) of edentulous maxillae.
Methods: Six typodonts were fabricated for different palatal morphologies with flat (F), medium (M), and deep (D) palates, with palatal wrinkles (W), or smooth palates (S), resulting in six groups: WF, WM, WD and SF, SM, SD. Ten scans were performed for each group; standard tessellation language files obtained were imported into a software to measure trueness and precision in micrometer. Trueness was calculated as the mean of the standard deviation values obtained by superimposing each scan onto the reference scan. Precision was achieved by overlapping each scan with that with the best trueness in the group. Descriptive and post-hoc analyses were conducted.
Results: The mean values for trueness were as follows: WM=48.7±4.7, WD=161.7±18.4, WF=85.9±16, SM=48.1±2.4, SD=349.9±8.8, and SF=349.1±25.5. The precision values were as follows: WM=46.7±7.3, WD=46.9±9, WF=48.9±6.7, SM=46±2.7, SD=105.9±17.4, SF=72.6±10.8. Significant differences were observed for trueness between SM and SD (P < 0.001), SM and SF (P < 0.001), and WF and SF (P = 0.003); whereas for precision, significant differences were reported between WD and SD (P = 0.015). Regarding trueness and precision, no difference was found between WM and SM (P = 1.0).
Conclusions: Medium palatal depth showed the best accuracy. The mean accuracy values were within the clinical acceptability thresholds for all palatal morphologies. The presence of rugae improved the precision of deeper palates and the trueness of flat palates. No differences were observed in the medium palates with or without rugae.