{"title":"基于能量函数的混合特高压直流输电先导保护方案(应用改进的豪斯多夫距离","authors":"Zijiang Wang;Youping Fan;Ben Shang;Yinbiao Shu","doi":"10.17775/CSEEJPES.2022.01330","DOIUrl":null,"url":null,"abstract":"A hybrid UHVDC transmission system applying LCC as the rectifier and MMC as the inverter combines the advantages of both converter types, which makes this protection scheme more complicated. A new pilot protection scheme for a three-terminal hybrid DC transmission system applying energy functions is proposed. The energy function for LCC is applied to MMC to derive the energy level of the hybrid system. Furthermore, an improved Hausdorff distance (IHD) algorithm is proposed to detect the difference in energy levels between the normal and fault states. An abrupt change in energy level is characterized by IHD change rate. Time points at which the IHD change rate exceeds the threshold at converter stations are applied to determine the fault line and to estimate the fault section. The proposed protection scheme is then verified by a simulation model of the Wudongde ±800 kV three-terminal hybrid UHVDC transmission project. The appropriate sampling frequency is selected for a real-time calculation, and the threshold is selected considering the effect of noise. Results show the proposed scheme can identify and trip fault lines quickly and effectively, even for a 600 Ω grounding fault. Other waveshape similarity algorithms are compared and analyzed. Compared with existing protection schemes, the proposed scheme transmits less data to improve communication speed and reliability.","PeriodicalId":10729,"journal":{"name":"CSEE Journal of Power and Energy Systems","volume":"10 3","pages":"891-902"},"PeriodicalIF":6.9000,"publicationDate":"2023-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10058878","citationCount":"0","resultStr":"{\"title\":\"Energy-Function Based Pilot Protection Scheme for Hybrid UHVDC Transmission Applying Improved Hausdorff Distance\",\"authors\":\"Zijiang Wang;Youping Fan;Ben Shang;Yinbiao Shu\",\"doi\":\"10.17775/CSEEJPES.2022.01330\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A hybrid UHVDC transmission system applying LCC as the rectifier and MMC as the inverter combines the advantages of both converter types, which makes this protection scheme more complicated. A new pilot protection scheme for a three-terminal hybrid DC transmission system applying energy functions is proposed. The energy function for LCC is applied to MMC to derive the energy level of the hybrid system. Furthermore, an improved Hausdorff distance (IHD) algorithm is proposed to detect the difference in energy levels between the normal and fault states. An abrupt change in energy level is characterized by IHD change rate. Time points at which the IHD change rate exceeds the threshold at converter stations are applied to determine the fault line and to estimate the fault section. The proposed protection scheme is then verified by a simulation model of the Wudongde ±800 kV three-terminal hybrid UHVDC transmission project. The appropriate sampling frequency is selected for a real-time calculation, and the threshold is selected considering the effect of noise. Results show the proposed scheme can identify and trip fault lines quickly and effectively, even for a 600 Ω grounding fault. Other waveshape similarity algorithms are compared and analyzed. Compared with existing protection schemes, the proposed scheme transmits less data to improve communication speed and reliability.\",\"PeriodicalId\":10729,\"journal\":{\"name\":\"CSEE Journal of Power and Energy Systems\",\"volume\":\"10 3\",\"pages\":\"891-902\"},\"PeriodicalIF\":6.9000,\"publicationDate\":\"2023-03-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10058878\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"CSEE Journal of Power and Energy Systems\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10058878/\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"CSEE Journal of Power and Energy Systems","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10058878/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
Energy-Function Based Pilot Protection Scheme for Hybrid UHVDC Transmission Applying Improved Hausdorff Distance
A hybrid UHVDC transmission system applying LCC as the rectifier and MMC as the inverter combines the advantages of both converter types, which makes this protection scheme more complicated. A new pilot protection scheme for a three-terminal hybrid DC transmission system applying energy functions is proposed. The energy function for LCC is applied to MMC to derive the energy level of the hybrid system. Furthermore, an improved Hausdorff distance (IHD) algorithm is proposed to detect the difference in energy levels between the normal and fault states. An abrupt change in energy level is characterized by IHD change rate. Time points at which the IHD change rate exceeds the threshold at converter stations are applied to determine the fault line and to estimate the fault section. The proposed protection scheme is then verified by a simulation model of the Wudongde ±800 kV three-terminal hybrid UHVDC transmission project. The appropriate sampling frequency is selected for a real-time calculation, and the threshold is selected considering the effect of noise. Results show the proposed scheme can identify and trip fault lines quickly and effectively, even for a 600 Ω grounding fault. Other waveshape similarity algorithms are compared and analyzed. Compared with existing protection schemes, the proposed scheme transmits less data to improve communication speed and reliability.
期刊介绍:
The CSEE Journal of Power and Energy Systems (JPES) is an international bimonthly journal published by the Chinese Society for Electrical Engineering (CSEE) in collaboration with CEPRI (China Electric Power Research Institute) and IEEE (The Institute of Electrical and Electronics Engineers) Inc. Indexed by SCI, Scopus, INSPEC, CSAD (Chinese Science Abstracts Database), DOAJ, and ProQuest, it serves as a platform for reporting cutting-edge theories, methods, technologies, and applications shaping the development of power systems in energy transition. The journal offers authors an international platform to enhance the reach and impact of their contributions.