Ramón Ruiz-Mesa, Gracia Castro de Luna, María Ruiz-Santos, Ana Jiménez-Nieto, Pedro Tañá-Rivero
{"title":"基于第 4 阶和第 6 阶球面像差组合的散光增强焦距眼内透镜的临床效果。","authors":"Ramón Ruiz-Mesa, Gracia Castro de Luna, María Ruiz-Santos, Ana Jiménez-Nieto, Pedro Tañá-Rivero","doi":"10.3928/1081597X-20240501-02","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the visual and refractive outcomes of patients implanted with a toric extended depth-of-focus (EDOF) intraocular lens (IOL) following cataract surgery.</p><p><strong>Methods: </strong>A total of 44 eyes implanted with the EDOF LuxSmart toric IOL were evaluated 4 to 6 months postoperatively. The main outcomes measurements evaluated were refractive error, rotational stability, distance, intermediate, and near visual acuities, defocus curve, photopic and mesopic contrast sensitivity, wavefront aberrations, and modulation transfer function, and the Catquest-9SF-questionnaire.</p><p><strong>Results: </strong>The mean postoperative spherical equivalent and cylinder were -0.02 ± 0.26 and -0.17 ± 0.29 diopters (D), respectively. A total of 90.45% and 100% of the eyes had a postoperative spherical equivalent within ±0.50 and ±1.00 D, respectively (this being 93.18% and 100% for the refractive cylinder). The mean rotational stability was 0.61 ± 1.61 degrees. The mean binocular corrected distance visual acuity (CDVA), corrected distance intermediate visual acuity (CDIVA), and corrected distance near visual acuity (CDNVA) were -0.02 ± 0.06, 0.07 ± 0.08, and 0.26 ± 0.09 logMAR, respectively. The CDVA was 20/25 or better in 95.45% of patients, CDIVA was 20/25 or better in 72.73%, and CDNVA was 20/40 or better in 72.73%. The defocus curve showed good visual acuity at distance and intermediate vergences. The contrast sensitivity and optical quality outcomes were good with mean higher order, spherical, and coma aberration values of 0.161 ± 0.155, -0.019 ± 0.048, and 0.080 ± 0.065 µm, respectively. A total of 90.9% of patients were either fairly satisfied or very satisfied with their vision after the surgery, and 77.7% of patients reported no difficulties when reading text in newspapers.</p><p><strong>Conclusions: </strong>Implantation of the toric pure refractive EDOF technology IOL provides good refractive, optical, and visual quality at different distances, with high levels of patient satisfaction being reported. <b>[<i>J Refract Surg</i>. 2024;40(6):e398-e406.]</b>.</p>","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"40 6","pages":"e398-e406"},"PeriodicalIF":2.9000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Clinical Outcomes of a Toric Enhanced Depth-of-Focus Intraocular Lens Based on the Combination of 4th- and 6th-Order Spherical Aberration.\",\"authors\":\"Ramón Ruiz-Mesa, Gracia Castro de Luna, María Ruiz-Santos, Ana Jiménez-Nieto, Pedro Tañá-Rivero\",\"doi\":\"10.3928/1081597X-20240501-02\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To assess the visual and refractive outcomes of patients implanted with a toric extended depth-of-focus (EDOF) intraocular lens (IOL) following cataract surgery.</p><p><strong>Methods: </strong>A total of 44 eyes implanted with the EDOF LuxSmart toric IOL were evaluated 4 to 6 months postoperatively. The main outcomes measurements evaluated were refractive error, rotational stability, distance, intermediate, and near visual acuities, defocus curve, photopic and mesopic contrast sensitivity, wavefront aberrations, and modulation transfer function, and the Catquest-9SF-questionnaire.</p><p><strong>Results: </strong>The mean postoperative spherical equivalent and cylinder were -0.02 ± 0.26 and -0.17 ± 0.29 diopters (D), respectively. A total of 90.45% and 100% of the eyes had a postoperative spherical equivalent within ±0.50 and ±1.00 D, respectively (this being 93.18% and 100% for the refractive cylinder). The mean rotational stability was 0.61 ± 1.61 degrees. The mean binocular corrected distance visual acuity (CDVA), corrected distance intermediate visual acuity (CDIVA), and corrected distance near visual acuity (CDNVA) were -0.02 ± 0.06, 0.07 ± 0.08, and 0.26 ± 0.09 logMAR, respectively. The CDVA was 20/25 or better in 95.45% of patients, CDIVA was 20/25 or better in 72.73%, and CDNVA was 20/40 or better in 72.73%. The defocus curve showed good visual acuity at distance and intermediate vergences. The contrast sensitivity and optical quality outcomes were good with mean higher order, spherical, and coma aberration values of 0.161 ± 0.155, -0.019 ± 0.048, and 0.080 ± 0.065 µm, respectively. A total of 90.9% of patients were either fairly satisfied or very satisfied with their vision after the surgery, and 77.7% of patients reported no difficulties when reading text in newspapers.</p><p><strong>Conclusions: </strong>Implantation of the toric pure refractive EDOF technology IOL provides good refractive, optical, and visual quality at different distances, with high levels of patient satisfaction being reported. <b>[<i>J Refract Surg</i>. 2024;40(6):e398-e406.]</b>.</p>\",\"PeriodicalId\":16951,\"journal\":{\"name\":\"Journal of refractive surgery\",\"volume\":\"40 6\",\"pages\":\"e398-e406\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of refractive surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3928/1081597X-20240501-02\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597X-20240501-02","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Clinical Outcomes of a Toric Enhanced Depth-of-Focus Intraocular Lens Based on the Combination of 4th- and 6th-Order Spherical Aberration.
Purpose: To assess the visual and refractive outcomes of patients implanted with a toric extended depth-of-focus (EDOF) intraocular lens (IOL) following cataract surgery.
Methods: A total of 44 eyes implanted with the EDOF LuxSmart toric IOL were evaluated 4 to 6 months postoperatively. The main outcomes measurements evaluated were refractive error, rotational stability, distance, intermediate, and near visual acuities, defocus curve, photopic and mesopic contrast sensitivity, wavefront aberrations, and modulation transfer function, and the Catquest-9SF-questionnaire.
Results: The mean postoperative spherical equivalent and cylinder were -0.02 ± 0.26 and -0.17 ± 0.29 diopters (D), respectively. A total of 90.45% and 100% of the eyes had a postoperative spherical equivalent within ±0.50 and ±1.00 D, respectively (this being 93.18% and 100% for the refractive cylinder). The mean rotational stability was 0.61 ± 1.61 degrees. The mean binocular corrected distance visual acuity (CDVA), corrected distance intermediate visual acuity (CDIVA), and corrected distance near visual acuity (CDNVA) were -0.02 ± 0.06, 0.07 ± 0.08, and 0.26 ± 0.09 logMAR, respectively. The CDVA was 20/25 or better in 95.45% of patients, CDIVA was 20/25 or better in 72.73%, and CDNVA was 20/40 or better in 72.73%. The defocus curve showed good visual acuity at distance and intermediate vergences. The contrast sensitivity and optical quality outcomes were good with mean higher order, spherical, and coma aberration values of 0.161 ± 0.155, -0.019 ± 0.048, and 0.080 ± 0.065 µm, respectively. A total of 90.9% of patients were either fairly satisfied or very satisfied with their vision after the surgery, and 77.7% of patients reported no difficulties when reading text in newspapers.
Conclusions: Implantation of the toric pure refractive EDOF technology IOL provides good refractive, optical, and visual quality at different distances, with high levels of patient satisfaction being reported. [J Refract Surg. 2024;40(6):e398-e406.].
期刊介绍:
The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as:
• Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics”
• Supplemental videos and materials available for many articles
• Access to current articles, as well as several years of archived content
• Articles posted online just 2 months after acceptance.