{"title":"对工程木材炭化层形成和损失的观察和影响","authors":"Laura Schmidt ,&nbsp;Rory M. Hadden ,&nbsp;Dilum Fernando","doi":"10.1016/j.firesaf.2024.104196","DOIUrl":null,"url":null,"abstract":"<div><p>The char layer plays a critical role in the fire behaviour of engineered timber. Several chemical and physical processes can reduce char layer thickness and integrity. A series of experiments studied 12 cross-laminated timber (CLT) columns (130 × 790 × 125 mm WxHxD) exposed to combined thermal (20 kW/m<sup>2</sup> or 50 kW/m<sup>2</sup>) and mechanical loading (39 kN, eccentric). Char loss from the surface lamella was observed and the impact of this on the thermal response of the timber studied. In all cases, unprotected CLT exhibited fall-off of charred pieces. Cracking, shrinkage and movement of char contributed significantly to the exposure of underlying timber sections to external heating. There was no direct correlation between char fall-off and the measured glue line temperature in this configuration. To enable comparison between CLT with and without char fall-off, a thin layer of glass fibre-reinforced polymer was added to the exposed surface of six samples which prevented all char fall-off. Retention of the char layer significantly decreased temperatures beneath the char layer, loss of section and burning duration compared to samples with char fall-off.</p></div>","PeriodicalId":50445,"journal":{"name":"Fire Safety Journal","volume":"147 ","pages":"Article 104196"},"PeriodicalIF":3.4000,"publicationDate":"2024-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0379711224001097/pdfft?md5=7c573cfadd13df493aa686555f4ab349&pid=1-s2.0-S0379711224001097-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Observations and impact of char layer formation and loss for engineered timber\",\"authors\":\"Laura Schmidt ,&nbsp;Rory M. Hadden ,&nbsp;Dilum Fernando\",\"doi\":\"10.1016/j.firesaf.2024.104196\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The char layer plays a critical role in the fire behaviour of engineered timber. Several chemical and physical processes can reduce char layer thickness and integrity. A series of experiments studied 12 cross-laminated timber (CLT) columns (130 × 790 × 125 mm WxHxD) exposed to combined thermal (20 kW/m<sup>2</sup> or 50 kW/m<sup>2</sup>) and mechanical loading (39 kN, eccentric). Char loss from the surface lamella was observed and the impact of this on the thermal response of the timber studied. In all cases, unprotected CLT exhibited fall-off of charred pieces. Cracking, shrinkage and movement of char contributed significantly to the exposure of underlying timber sections to external heating. There was no direct correlation between char fall-off and the measured glue line temperature in this configuration. To enable comparison between CLT with and without char fall-off, a thin layer of glass fibre-reinforced polymer was added to the exposed surface of six samples which prevented all char fall-off. Retention of the char layer significantly decreased temperatures beneath the char layer, loss of section and burning duration compared to samples with char fall-off.</p></div>\",\"PeriodicalId\":50445,\"journal\":{\"name\":\"Fire Safety Journal\",\"volume\":\"147 \",\"pages\":\"Article 104196\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2024-06-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S0379711224001097/pdfft?md5=7c573cfadd13df493aa686555f4ab349&pid=1-s2.0-S0379711224001097-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fire Safety Journal\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0379711224001097\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire Safety Journal","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0379711224001097","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0

摘要

炭化层对工程木材的防火性能起着至关重要的作用。一些化学和物理过程可以减少炭化层的厚度和完整性。一系列实验研究了 12 根交叉层压木材(CLT)柱子(130 × 790 × 125 mm WxHxD),这些柱子暴露在热荷载(20 kW/m2 或 50 kW/m2)和机械荷载(39 kN,偏心)的双重作用下。观察了表面薄片的炭化损失,并研究了这对木材热反应的影响。在所有情况下,未受保护的 CLT 都会出现炭化块脱落的现象。裂缝、收缩和炭化移动在很大程度上导致下层木材暴露于外部加热。在这种结构中,木炭脱落与测量到的胶线温度之间没有直接关联。为了对有无木炭脱落的 CLT 进行比较,在六个样本的暴露表面添加了一薄层玻璃纤维增强聚合物,以防止所有木炭脱落。与有木炭脱落的样品相比,保留木炭层可大大降低木炭层下的温度、截面损失和燃烧持续时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Observations and impact of char layer formation and loss for engineered timber

Observations and impact of char layer formation and loss for engineered timber

The char layer plays a critical role in the fire behaviour of engineered timber. Several chemical and physical processes can reduce char layer thickness and integrity. A series of experiments studied 12 cross-laminated timber (CLT) columns (130 × 790 × 125 mm WxHxD) exposed to combined thermal (20 kW/m2 or 50 kW/m2) and mechanical loading (39 kN, eccentric). Char loss from the surface lamella was observed and the impact of this on the thermal response of the timber studied. In all cases, unprotected CLT exhibited fall-off of charred pieces. Cracking, shrinkage and movement of char contributed significantly to the exposure of underlying timber sections to external heating. There was no direct correlation between char fall-off and the measured glue line temperature in this configuration. To enable comparison between CLT with and without char fall-off, a thin layer of glass fibre-reinforced polymer was added to the exposed surface of six samples which prevented all char fall-off. Retention of the char layer significantly decreased temperatures beneath the char layer, loss of section and burning duration compared to samples with char fall-off.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Fire Safety Journal
Fire Safety Journal 工程技术-材料科学:综合
CiteScore
5.70
自引率
9.70%
发文量
153
审稿时长
60 days
期刊介绍: Fire Safety Journal is the leading publication dealing with all aspects of fire safety engineering. Its scope is purposefully wide, as it is deemed important to encourage papers from all sources within this multidisciplinary subject, thus providing a forum for its further development as a distinct engineering discipline. This is an essential step towards gaining a status equal to that enjoyed by the other engineering disciplines.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信