二维电子光学多光子显微镜。

IF 4.8 2区 医学 Q1 NEUROSCIENCES
Neurophotonics Pub Date : 2024-04-01 Epub Date: 2024-06-05 DOI:10.1117/1.NPh.11.2.025005
Deano M Farinella, Samuel Stanek, Harishankar Jayakumar, Zachary L Newman, Jacob Gable, James Leger, Aaron Kerlin
{"title":"二维电子光学多光子显微镜。","authors":"Deano M Farinella, Samuel Stanek, Harishankar Jayakumar, Zachary L Newman, Jacob Gable, James Leger, Aaron Kerlin","doi":"10.1117/1.NPh.11.2.025005","DOIUrl":null,"url":null,"abstract":"<p><strong>Significance: </strong>The development of genetically encoded fluorescent indicators of neural activity with millisecond dynamics has generated demand for ever faster two-photon (2P) imaging systems, but acoustic and mechanical beam scanning technologies are approaching fundamental limits. We demonstrate that potassium tantalate niobate (KTN) electro-optical deflectors (EODs), which are not subject to the same fundamental limits, are capable of ultrafast two-dimensional (2D) 2P imaging <i>in vivo</i>.</p><p><strong>Aim: </strong>To determine if KTN-EODs are suitable for 2P imaging, compatible with 2D scanning, and capable of ultrafast <i>in vivo</i> imaging of genetically encoded indicators with millisecond dynamics.</p><p><strong>Approach: </strong>The performance of a commercially available KTN-EOD was characterized across a range of drive frequencies and laser parameters relevant to <i>in vivo</i> 2P microscopy. A second KTN-EOD was incorporated into a dual-axis scan module, and the system was validated by imaging signals <i>in vivo</i> from ASAP3, a genetically encoded voltage indicator.</p><p><strong>Results: </strong>Optimal KTN-EOD deflection of laser light with a central wavelength of 960 nm was obtained up to the highest average powers and pulse intensities tested (power: 350 mW; pulse duration: 118 fs). Up to 32 resolvable spots per line at a 560 kHz line scan rate could be obtained with single-axis deflection. The complete dual-axis EO 2P microscope was capable of imaging a <math><mrow><mn>13</mn><mtext>  </mtext><mi>μ</mi><mi>m</mi></mrow></math> by <math><mrow><mn>13</mn><mtext>  </mtext><mi>μ</mi><mi>m</mi></mrow></math> field-of-view at over 10 kHz frame rate with <math><mrow><mo>∼</mo><mn>0.5</mn><mtext>  </mtext><mi>μ</mi><mi>m</mi></mrow></math> lateral resolution. We demonstrate <i>in vivo</i> imaging of neurons expressing ASAP3 with high temporal resolution.</p><p><strong>Conclusions: </strong>We demonstrate the suitability of KTN-EODs for ultrafast 2P cellular imaging <i>in vivo</i>, providing a foundation for future high-performance microscopes to incorporate emerging advances in KTN-based scanning technology.</p>","PeriodicalId":54335,"journal":{"name":"Neurophotonics","volume":"11 2","pages":"025005"},"PeriodicalIF":4.8000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11151658/pdf/","citationCount":"0","resultStr":"{\"title\":\"Two-dimensional electro-optical multiphoton microscopy.\",\"authors\":\"Deano M Farinella, Samuel Stanek, Harishankar Jayakumar, Zachary L Newman, Jacob Gable, James Leger, Aaron Kerlin\",\"doi\":\"10.1117/1.NPh.11.2.025005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Significance: </strong>The development of genetically encoded fluorescent indicators of neural activity with millisecond dynamics has generated demand for ever faster two-photon (2P) imaging systems, but acoustic and mechanical beam scanning technologies are approaching fundamental limits. We demonstrate that potassium tantalate niobate (KTN) electro-optical deflectors (EODs), which are not subject to the same fundamental limits, are capable of ultrafast two-dimensional (2D) 2P imaging <i>in vivo</i>.</p><p><strong>Aim: </strong>To determine if KTN-EODs are suitable for 2P imaging, compatible with 2D scanning, and capable of ultrafast <i>in vivo</i> imaging of genetically encoded indicators with millisecond dynamics.</p><p><strong>Approach: </strong>The performance of a commercially available KTN-EOD was characterized across a range of drive frequencies and laser parameters relevant to <i>in vivo</i> 2P microscopy. A second KTN-EOD was incorporated into a dual-axis scan module, and the system was validated by imaging signals <i>in vivo</i> from ASAP3, a genetically encoded voltage indicator.</p><p><strong>Results: </strong>Optimal KTN-EOD deflection of laser light with a central wavelength of 960 nm was obtained up to the highest average powers and pulse intensities tested (power: 350 mW; pulse duration: 118 fs). Up to 32 resolvable spots per line at a 560 kHz line scan rate could be obtained with single-axis deflection. The complete dual-axis EO 2P microscope was capable of imaging a <math><mrow><mn>13</mn><mtext>  </mtext><mi>μ</mi><mi>m</mi></mrow></math> by <math><mrow><mn>13</mn><mtext>  </mtext><mi>μ</mi><mi>m</mi></mrow></math> field-of-view at over 10 kHz frame rate with <math><mrow><mo>∼</mo><mn>0.5</mn><mtext>  </mtext><mi>μ</mi><mi>m</mi></mrow></math> lateral resolution. We demonstrate <i>in vivo</i> imaging of neurons expressing ASAP3 with high temporal resolution.</p><p><strong>Conclusions: </strong>We demonstrate the suitability of KTN-EODs for ultrafast 2P cellular imaging <i>in vivo</i>, providing a foundation for future high-performance microscopes to incorporate emerging advances in KTN-based scanning technology.</p>\",\"PeriodicalId\":54335,\"journal\":{\"name\":\"Neurophotonics\",\"volume\":\"11 2\",\"pages\":\"025005\"},\"PeriodicalIF\":4.8000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11151658/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Neurophotonics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1117/1.NPh.11.2.025005\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/5 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"NEUROSCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurophotonics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1117/1.NPh.11.2.025005","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/5 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

意义重大:具有毫秒级动态的神经活动基因编码荧光指示器的开发,催生了对更快的双光子(2P)成像系统的需求,但声学和机械光束扫描技术已接近基本极限。我们证明,钽酸铌酸钾(KTN)电子光学偏转器(EOD)不受同样的基本限制,能够在体内进行超快二维(2D)双光子成像。目的:确定 KTN-EOD 是否适用于双光子成像,是否与二维扫描兼容,是否能够在体内对具有毫秒级动态的基因编码指标进行超快成像:方法:在与活体 2P 显微镜相关的驱动频率和激光参数范围内,对商用 KTN-EOD 的性能进行了鉴定。在双轴扫描模块中加入了第二个 KTN-EOD,并通过对基因编码电压指示器 ASAP3 的体内信号成像对系统进行了验证:结果:在测试的最高平均功率和脉冲强度(功率:350 mW;脉冲持续时间:118 fs)条件下,中心波长为 960 nm 的 KTN-EOD 可获得最佳激光偏转。在 560 kHz 的行扫描速率下,单轴偏转最多可获得每行 32 个可分辨光斑。完整的双轴 EO 2P 显微镜能够以超过 10 kHz 的帧速率对 13 μm x 13 μm 的视场进行成像,横向分辨率为 0.5 μm。我们展示了表达 ASAP3 的神经元在体内的高时间分辨率成像:我们证明了 KTN-EODs 适用于体内超快 2P 细胞成像,为未来高性能显微镜采用基于 KTN 的新兴扫描技术奠定了基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Two-dimensional electro-optical multiphoton microscopy.

Significance: The development of genetically encoded fluorescent indicators of neural activity with millisecond dynamics has generated demand for ever faster two-photon (2P) imaging systems, but acoustic and mechanical beam scanning technologies are approaching fundamental limits. We demonstrate that potassium tantalate niobate (KTN) electro-optical deflectors (EODs), which are not subject to the same fundamental limits, are capable of ultrafast two-dimensional (2D) 2P imaging in vivo.

Aim: To determine if KTN-EODs are suitable for 2P imaging, compatible with 2D scanning, and capable of ultrafast in vivo imaging of genetically encoded indicators with millisecond dynamics.

Approach: The performance of a commercially available KTN-EOD was characterized across a range of drive frequencies and laser parameters relevant to in vivo 2P microscopy. A second KTN-EOD was incorporated into a dual-axis scan module, and the system was validated by imaging signals in vivo from ASAP3, a genetically encoded voltage indicator.

Results: Optimal KTN-EOD deflection of laser light with a central wavelength of 960 nm was obtained up to the highest average powers and pulse intensities tested (power: 350 mW; pulse duration: 118 fs). Up to 32 resolvable spots per line at a 560 kHz line scan rate could be obtained with single-axis deflection. The complete dual-axis EO 2P microscope was capable of imaging a 13  μm by 13  μm field-of-view at over 10 kHz frame rate with 0.5  μm lateral resolution. We demonstrate in vivo imaging of neurons expressing ASAP3 with high temporal resolution.

Conclusions: We demonstrate the suitability of KTN-EODs for ultrafast 2P cellular imaging in vivo, providing a foundation for future high-performance microscopes to incorporate emerging advances in KTN-based scanning technology.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Neurophotonics
Neurophotonics Neuroscience-Neuroscience (miscellaneous)
CiteScore
7.20
自引率
11.30%
发文量
114
审稿时长
21 weeks
期刊介绍: At the interface of optics and neuroscience, Neurophotonics is a peer-reviewed journal that covers advances in optical technology applicable to study of the brain and their impact on the basic and clinical neuroscience applications.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信