使用家用血压计测量的睡眠血压与心血管疾病发病率密切相关:长滨研究。

IF 4.3 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC
ACS Applied Electronic Materials Pub Date : 2024-10-01 Epub Date: 2024-05-27 DOI:10.1097/HJH.0000000000003781
Yasuharu Tabara, Takeshi Matsumoto, Kimihiko Murase, Kazuya Setoh, Takahisa Kawaguchi, Tomoko Wakamura, Toyohiro Hirai, Kazuo Chin, Fumihiko Matsuda
{"title":"使用家用血压计测量的睡眠血压与心血管疾病发病率密切相关:长滨研究。","authors":"Yasuharu Tabara, Takeshi Matsumoto, Kimihiko Murase, Kazuya Setoh, Takahisa Kawaguchi, Tomoko Wakamura, Toyohiro Hirai, Kazuo Chin, Fumihiko Matsuda","doi":"10.1097/HJH.0000000000003781","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Nocturnal blood pressure (BP) is associated with cardiovascular disease independently of awake BP. However, nocturnal BP measured using an ambulatory monitoring device has limited reproducibility because it is a single-day measurement. We investigated the association between sleep BP measured on multiple days using a timer-equipped home BP monitor and cardiovascular diseases in a general population.</p><p><strong>Methods: </strong>The study population comprised 5814 community residents. Participants were required to sleep with wrapping cuffs on their upper arm and BP was measured automatically at 0 : 00, 2 : 00, and 4 : 00. Actigraph was used to determine BP measured during sleep. Participants were also measured home morning and evening BP manually using the same device.</p><p><strong>Results: </strong>During the 7.3-year mean follow-up period, we observed 117 cases of cardiovascular diseases. The association between sleep BP (per 10 mmHg hazard ratio = 1.31, P  < 0.001) and cardiovascular events remained significant (hazard ratio = 1.22, P  = 0.036) even after adjusting for office BP and confounding factors, such as sleep-disordered breathing. Individuals with sleep-only hypertension ( n  = 1047; hazard ratio = 2.23, P  = 0.005) had a significant cardiovascular risk. Daytime-only hypertension ( n  = 264; hazard ratio = 3.57, P  = 0.001) and combined sleep and daytime hypertension ( n  = 1216; hazard ratio = 3.69, P  < 0.001) was associated with cardiovascular events to the same extent. Sleep BP dipping was not identified as a significant determinant of cardiovascular events.</p><p><strong>Conclusion: </strong>Sleep BP measured using a home BP monitor was independently associated with the incidence of cardiovascular disease in a general population.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Sleep blood pressure measured using a home blood pressure monitor was independently associated with cardiovascular disease incidence: the Nagahama study.\",\"authors\":\"Yasuharu Tabara, Takeshi Matsumoto, Kimihiko Murase, Kazuya Setoh, Takahisa Kawaguchi, Tomoko Wakamura, Toyohiro Hirai, Kazuo Chin, Fumihiko Matsuda\",\"doi\":\"10.1097/HJH.0000000000003781\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Nocturnal blood pressure (BP) is associated with cardiovascular disease independently of awake BP. However, nocturnal BP measured using an ambulatory monitoring device has limited reproducibility because it is a single-day measurement. We investigated the association between sleep BP measured on multiple days using a timer-equipped home BP monitor and cardiovascular diseases in a general population.</p><p><strong>Methods: </strong>The study population comprised 5814 community residents. Participants were required to sleep with wrapping cuffs on their upper arm and BP was measured automatically at 0 : 00, 2 : 00, and 4 : 00. Actigraph was used to determine BP measured during sleep. Participants were also measured home morning and evening BP manually using the same device.</p><p><strong>Results: </strong>During the 7.3-year mean follow-up period, we observed 117 cases of cardiovascular diseases. The association between sleep BP (per 10 mmHg hazard ratio = 1.31, P  < 0.001) and cardiovascular events remained significant (hazard ratio = 1.22, P  = 0.036) even after adjusting for office BP and confounding factors, such as sleep-disordered breathing. Individuals with sleep-only hypertension ( n  = 1047; hazard ratio = 2.23, P  = 0.005) had a significant cardiovascular risk. Daytime-only hypertension ( n  = 264; hazard ratio = 3.57, P  = 0.001) and combined sleep and daytime hypertension ( n  = 1216; hazard ratio = 3.69, P  < 0.001) was associated with cardiovascular events to the same extent. Sleep BP dipping was not identified as a significant determinant of cardiovascular events.</p><p><strong>Conclusion: </strong>Sleep BP measured using a home BP monitor was independently associated with the incidence of cardiovascular disease in a general population.</p>\",\"PeriodicalId\":3,\"journal\":{\"name\":\"ACS Applied Electronic Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Electronic Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/HJH.0000000000003781\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/27 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/HJH.0000000000003781","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/27 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

背景:夜间血压(BP)与心血管疾病有关,与清醒血压无关。然而,使用非卧床监测设备测量夜间血压的可重复性有限,因为它是单日测量。我们研究了在普通人群中使用配备定时器的家用血压计测量多日睡眠血压与心血管疾病之间的关系:研究对象包括 5814 名社区居民。参与者睡觉时必须在上臂缠绕袖带,并在 0 :00, 2 :00 和 4 :00.使用 Actigraph 测定睡眠时的血压。此外,还使用同一设备手动测量参与者的家庭早晚血压:结果:在平均 7.3 年的随访期间,我们观察到 117 例心血管疾病患者。睡眠血压(每 10 mmHg 危险比=1.31,P=0)与心血管疾病之间存在关联:在普通人群中,使用家用血压计测量的睡眠血压与心血管疾病的发病率有独立关联。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Sleep blood pressure measured using a home blood pressure monitor was independently associated with cardiovascular disease incidence: the Nagahama study.

Background: Nocturnal blood pressure (BP) is associated with cardiovascular disease independently of awake BP. However, nocturnal BP measured using an ambulatory monitoring device has limited reproducibility because it is a single-day measurement. We investigated the association between sleep BP measured on multiple days using a timer-equipped home BP monitor and cardiovascular diseases in a general population.

Methods: The study population comprised 5814 community residents. Participants were required to sleep with wrapping cuffs on their upper arm and BP was measured automatically at 0 : 00, 2 : 00, and 4 : 00. Actigraph was used to determine BP measured during sleep. Participants were also measured home morning and evening BP manually using the same device.

Results: During the 7.3-year mean follow-up period, we observed 117 cases of cardiovascular diseases. The association between sleep BP (per 10 mmHg hazard ratio = 1.31, P  < 0.001) and cardiovascular events remained significant (hazard ratio = 1.22, P  = 0.036) even after adjusting for office BP and confounding factors, such as sleep-disordered breathing. Individuals with sleep-only hypertension ( n  = 1047; hazard ratio = 2.23, P  = 0.005) had a significant cardiovascular risk. Daytime-only hypertension ( n  = 264; hazard ratio = 3.57, P  = 0.001) and combined sleep and daytime hypertension ( n  = 1216; hazard ratio = 3.69, P  < 0.001) was associated with cardiovascular events to the same extent. Sleep BP dipping was not identified as a significant determinant of cardiovascular events.

Conclusion: Sleep BP measured using a home BP monitor was independently associated with the incidence of cardiovascular disease in a general population.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信