Romana Urinovska, Pavel Sistik, Marek Buzga, David Stejskal
{"title":"利用 LC/MS/MS 快速简便地同时测定减肥患者血清中的核黄素、叶酸、全反式-视黄醇和 α-生育酚。","authors":"Romana Urinovska, Pavel Sistik, Marek Buzga, David Stejskal","doi":"10.1093/chromsci/bmae035","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to develop and validate methods for the determination of vitamins B2, B9, E and A in serum using liquid chromatography with mass spectrometry (MS) detection. Vitamin analysis was performed using an ultra performance liquid chromatography combined with tandem MS. The compounds were separated on a BEH C18 RP column (2.1 × 100 mm, 1.7 μm) using a gradient elution with an analysis time of 10 min. Sample preparation included protein precipitation with ethanol. The concentration range in human serum was as follows: riboflavin 5-1000 nmol/L, folic acid 2.5-250 nmol/L, α-tocopherol 0.5-100 μmol/L and all-trans-retinol 25-2500 nmol/L. Accuracy and precision were validated according to Food and Drug Administration guidelines, with coefficients of variation ranging from 3.1-11.7% and recoveries from 94.4-107.5%. Routine monitoring of the complex range of vitamins in bariatric medicine is still not common. This is despite the fact that patients are at risk for glitch deficits, especially of a neurological nature. An analytical method that allows for the complex measurement of both water-soluble and fat-soluble vitamins is important and necessary for the clinical monitoring of bariatric patients. The method we have described could benefit both clinical practice and nutritional research.</p>","PeriodicalId":15430,"journal":{"name":"Journal of chromatographic science","volume":" ","pages":"767-775"},"PeriodicalIF":1.5000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fast and Easy Simultaneous Determination of Riboflavin, Folic Acid, All-Trans-Retinol and α-Tocopherol in Human Serum by LC/MS/MS for Bariatric Patients.\",\"authors\":\"Romana Urinovska, Pavel Sistik, Marek Buzga, David Stejskal\",\"doi\":\"10.1093/chromsci/bmae035\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of this study was to develop and validate methods for the determination of vitamins B2, B9, E and A in serum using liquid chromatography with mass spectrometry (MS) detection. Vitamin analysis was performed using an ultra performance liquid chromatography combined with tandem MS. The compounds were separated on a BEH C18 RP column (2.1 × 100 mm, 1.7 μm) using a gradient elution with an analysis time of 10 min. Sample preparation included protein precipitation with ethanol. The concentration range in human serum was as follows: riboflavin 5-1000 nmol/L, folic acid 2.5-250 nmol/L, α-tocopherol 0.5-100 μmol/L and all-trans-retinol 25-2500 nmol/L. Accuracy and precision were validated according to Food and Drug Administration guidelines, with coefficients of variation ranging from 3.1-11.7% and recoveries from 94.4-107.5%. Routine monitoring of the complex range of vitamins in bariatric medicine is still not common. This is despite the fact that patients are at risk for glitch deficits, especially of a neurological nature. An analytical method that allows for the complex measurement of both water-soluble and fat-soluble vitamins is important and necessary for the clinical monitoring of bariatric patients. The method we have described could benefit both clinical practice and nutritional research.</p>\",\"PeriodicalId\":15430,\"journal\":{\"name\":\"Journal of chromatographic science\",\"volume\":\" \",\"pages\":\"767-775\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of chromatographic science\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1093/chromsci/bmae035\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of chromatographic science","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1093/chromsci/bmae035","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Fast and Easy Simultaneous Determination of Riboflavin, Folic Acid, All-Trans-Retinol and α-Tocopherol in Human Serum by LC/MS/MS for Bariatric Patients.
The aim of this study was to develop and validate methods for the determination of vitamins B2, B9, E and A in serum using liquid chromatography with mass spectrometry (MS) detection. Vitamin analysis was performed using an ultra performance liquid chromatography combined with tandem MS. The compounds were separated on a BEH C18 RP column (2.1 × 100 mm, 1.7 μm) using a gradient elution with an analysis time of 10 min. Sample preparation included protein precipitation with ethanol. The concentration range in human serum was as follows: riboflavin 5-1000 nmol/L, folic acid 2.5-250 nmol/L, α-tocopherol 0.5-100 μmol/L and all-trans-retinol 25-2500 nmol/L. Accuracy and precision were validated according to Food and Drug Administration guidelines, with coefficients of variation ranging from 3.1-11.7% and recoveries from 94.4-107.5%. Routine monitoring of the complex range of vitamins in bariatric medicine is still not common. This is despite the fact that patients are at risk for glitch deficits, especially of a neurological nature. An analytical method that allows for the complex measurement of both water-soluble and fat-soluble vitamins is important and necessary for the clinical monitoring of bariatric patients. The method we have described could benefit both clinical practice and nutritional research.
期刊介绍:
The Journal of Chromatographic Science is devoted to the dissemination of information concerning all methods of chromatographic analysis. The standard manuscript is a description of recent original research that covers any or all phases of a specific separation problem, principle, or method. Manuscripts which have a high degree of novelty and fundamental significance to the field of separation science are particularly encouraged. It is expected the authors will clearly state in the Introduction how their method compares in some markedly new and improved way to previous published related methods. Analytical performance characteristics of new methods including sensitivity, tested limits of detection or quantification, accuracy, precision, and specificity should be provided. Manuscripts which describe a straightforward extension of a known analytical method or an application to a previously analyzed and/or uncomplicated sample matrix will not normally be reviewed favorably. Manuscripts in which mass spectrometry is the dominant analytical method and chromatography is of marked secondary importance may be declined.