在双颌正颌手术治疗骨骼类 II 型错颌畸形时,采用下颌先入法的患者特异性种植体与 CAD/CAM 夹板的准确性对比。

J Yan, B Li, C Zhang, Y Qian, Z Li, X Wang
{"title":"在双颌正颌手术治疗骨骼类 II 型错颌畸形时,采用下颌先入法的患者特异性种植体与 CAD/CAM 夹板的准确性对比。","authors":"J Yan, B Li, C Zhang, Y Qian, Z Li, X Wang","doi":"10.1016/j.ijom.2024.05.005","DOIUrl":null,"url":null,"abstract":"<p><p>This retrospective study aimed to compare the accuracy of patient-specific implants (PSI) versus mandible-first computer-aided design and manufacturing (CAD/CAM) splints for maxilla repositioning in orthognathic surgery of skeletal Class II malocclusion patients. The main predictor was the surgical method (PSI vs. splints), with the primary outcome being the discrepancy in maxilla centroid position, and secondary outcomes being translation and orientation discrepancies. A total of 82 patients were enrolled (70 female, 12 male; mean age 25.5 years), 41 in each group. The PSI group exhibited a median maxillary position discrepancy of 1.25 mm (interquartile range (IQR) 1.03 mm), significantly lower than the splint group's 1.98 mm (IQR 1.64 mm) (P < 0.001). In the PSI group, the largest median translation discrepancy was 0.74 mm (IQR 1.17 mm) in the anteroposterior direction, while the largest orientation discrepancy was 1.83° (IQR 1.63°) in pitch. In the splint group, the largest median translation discrepancy was 1.14 mm (IQR 1.37 mm) in the anteroposterior direction, while the largest orientation discrepancy was 3.03° (IQR 2.11°) in pitch. In conclusion, among patients with skeletal Class II malocclusion, the application of PSI in orthognathic surgery yielded increased precision in maxillary positioning compared to mandible-first CAD/CAM splints.</p>","PeriodicalId":94053,"journal":{"name":"International journal of oral and maxillofacial surgery","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accuracy of patient-specific implants versus CAD/CAM splints with the mandible-first approach in bimaxillary orthognathic surgery for skeletal Class II malocclusion.\",\"authors\":\"J Yan, B Li, C Zhang, Y Qian, Z Li, X Wang\",\"doi\":\"10.1016/j.ijom.2024.05.005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This retrospective study aimed to compare the accuracy of patient-specific implants (PSI) versus mandible-first computer-aided design and manufacturing (CAD/CAM) splints for maxilla repositioning in orthognathic surgery of skeletal Class II malocclusion patients. The main predictor was the surgical method (PSI vs. splints), with the primary outcome being the discrepancy in maxilla centroid position, and secondary outcomes being translation and orientation discrepancies. A total of 82 patients were enrolled (70 female, 12 male; mean age 25.5 years), 41 in each group. The PSI group exhibited a median maxillary position discrepancy of 1.25 mm (interquartile range (IQR) 1.03 mm), significantly lower than the splint group's 1.98 mm (IQR 1.64 mm) (P < 0.001). In the PSI group, the largest median translation discrepancy was 0.74 mm (IQR 1.17 mm) in the anteroposterior direction, while the largest orientation discrepancy was 1.83° (IQR 1.63°) in pitch. In the splint group, the largest median translation discrepancy was 1.14 mm (IQR 1.37 mm) in the anteroposterior direction, while the largest orientation discrepancy was 3.03° (IQR 2.11°) in pitch. In conclusion, among patients with skeletal Class II malocclusion, the application of PSI in orthognathic surgery yielded increased precision in maxillary positioning compared to mandible-first CAD/CAM splints.</p>\",\"PeriodicalId\":94053,\"journal\":{\"name\":\"International journal of oral and maxillofacial surgery\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of oral and maxillofacial surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1016/j.ijom.2024.05.005\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of oral and maxillofacial surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.ijom.2024.05.005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

这项回顾性研究旨在比较患者特异性种植体(PSI)与下颌骨先行计算机辅助设计和制造(CAD/CAM)夹板在骨骼Ⅱ类错颌畸形患者正颌手术中上颌骨复位的准确性。主要预测因素是手术方法(PSI 与夹板),主要结果是上颌骨中心点位置差异,次要结果是平移和方向差异。共有82名患者(70名女性,12名男性;平均年龄25.5岁)参加了此次研究,每组41人。PSI 组的上颌位置差异中位数为 1.25 毫米(四分位间距 1.03 毫米),明显低于夹板组的 1.98 毫米(四分位间距 1.64 毫米)(P<0.05)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Accuracy of patient-specific implants versus CAD/CAM splints with the mandible-first approach in bimaxillary orthognathic surgery for skeletal Class II malocclusion.

This retrospective study aimed to compare the accuracy of patient-specific implants (PSI) versus mandible-first computer-aided design and manufacturing (CAD/CAM) splints for maxilla repositioning in orthognathic surgery of skeletal Class II malocclusion patients. The main predictor was the surgical method (PSI vs. splints), with the primary outcome being the discrepancy in maxilla centroid position, and secondary outcomes being translation and orientation discrepancies. A total of 82 patients were enrolled (70 female, 12 male; mean age 25.5 years), 41 in each group. The PSI group exhibited a median maxillary position discrepancy of 1.25 mm (interquartile range (IQR) 1.03 mm), significantly lower than the splint group's 1.98 mm (IQR 1.64 mm) (P < 0.001). In the PSI group, the largest median translation discrepancy was 0.74 mm (IQR 1.17 mm) in the anteroposterior direction, while the largest orientation discrepancy was 1.83° (IQR 1.63°) in pitch. In the splint group, the largest median translation discrepancy was 1.14 mm (IQR 1.37 mm) in the anteroposterior direction, while the largest orientation discrepancy was 3.03° (IQR 2.11°) in pitch. In conclusion, among patients with skeletal Class II malocclusion, the application of PSI in orthognathic surgery yielded increased precision in maxillary positioning compared to mandible-first CAD/CAM splints.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信