基于热空化技术的 3D 打印无针注射器:在重复机制下分析皮肤模型中的冲击力和穿透深度。

IF 5.7 3区 医学 Q1 MEDICINE, RESEARCH & EXPERIMENTAL
Drug Delivery and Translational Research Pub Date : 2025-03-01 Epub Date: 2024-06-03 DOI:10.1007/s13346-024-01639-1
Rafael Zaca-Morán, Doris Giovanna Mitre-Martínez, Juan Castillo-Mixcóalt, Placido Zaca-Morán, Rubén Ramos-García, Julio César Ramírez-San-Juan, Carolina Morán-Raya, Juan Pablo Padilla-Martínez
{"title":"基于热空化技术的 3D 打印无针注射器:在重复机制下分析皮肤模型中的冲击力和穿透深度。","authors":"Rafael Zaca-Morán, Doris Giovanna Mitre-Martínez, Juan Castillo-Mixcóalt, Placido Zaca-Morán, Rubén Ramos-García, Julio César Ramírez-San-Juan, Carolina Morán-Raya, Juan Pablo Padilla-Martínez","doi":"10.1007/s13346-024-01639-1","DOIUrl":null,"url":null,"abstract":"<p><p>A global issue that requires attention is the duality between the shortage of needles for regular vaccination campaigns and the exponential increase in syringe and needle waste from such campaigns, which has been exacerbated by the COVID-19 pandemic. In response to this problem, this study presents a 3D printed needleless injector based on thermocavitation. The work focused on investigating the interaction of the resulting liquid jets with skin phantoms at different concentrations (1-2%), emphasizing their impact and penetration depth in a repetitive regime. The injector was designed and fabricated from a semi-transparent polymer using a high-resolution 3D printer, allowing the ejection of liquid jets with velocities up to ~ 73 m/s. The impact of these jets on skin phantoms was evaluated using a high-speed camera. After 6 consecutive liquid jets (1% concentration), a maximum penetration depth of ~ 2.5 mm was achieved, delivering approximately 4.7 µL. For the highest concentration (2.0%) and the same number of shots, the penetration depth was reduced to ~ 0.6 mm with a delivered volume of ~ 0.7 µL. An important finding of this study is that the liquid jet with the highest pressure does not cause the maximum penetration depth, but is the result of a series of successive shots. In addition, the velocity and shape of the ejected jet are determined by the amount of solution and the meniscus formed inside the injector. These findings advance the development of precise and efficient thermocavitation-based injectors with broad potential applications in medical and pharmaceutical fields.</p>","PeriodicalId":11357,"journal":{"name":"Drug Delivery and Translational Research","volume":" ","pages":"874-884"},"PeriodicalIF":5.7000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"3D printed needleless injector based on thermocavitation: analysis of impact and penetration depth in skin phantoms in a repetitive regime.\",\"authors\":\"Rafael Zaca-Morán, Doris Giovanna Mitre-Martínez, Juan Castillo-Mixcóalt, Placido Zaca-Morán, Rubén Ramos-García, Julio César Ramírez-San-Juan, Carolina Morán-Raya, Juan Pablo Padilla-Martínez\",\"doi\":\"10.1007/s13346-024-01639-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A global issue that requires attention is the duality between the shortage of needles for regular vaccination campaigns and the exponential increase in syringe and needle waste from such campaigns, which has been exacerbated by the COVID-19 pandemic. In response to this problem, this study presents a 3D printed needleless injector based on thermocavitation. The work focused on investigating the interaction of the resulting liquid jets with skin phantoms at different concentrations (1-2%), emphasizing their impact and penetration depth in a repetitive regime. The injector was designed and fabricated from a semi-transparent polymer using a high-resolution 3D printer, allowing the ejection of liquid jets with velocities up to ~ 73 m/s. The impact of these jets on skin phantoms was evaluated using a high-speed camera. After 6 consecutive liquid jets (1% concentration), a maximum penetration depth of ~ 2.5 mm was achieved, delivering approximately 4.7 µL. For the highest concentration (2.0%) and the same number of shots, the penetration depth was reduced to ~ 0.6 mm with a delivered volume of ~ 0.7 µL. An important finding of this study is that the liquid jet with the highest pressure does not cause the maximum penetration depth, but is the result of a series of successive shots. In addition, the velocity and shape of the ejected jet are determined by the amount of solution and the meniscus formed inside the injector. These findings advance the development of precise and efficient thermocavitation-based injectors with broad potential applications in medical and pharmaceutical fields.</p>\",\"PeriodicalId\":11357,\"journal\":{\"name\":\"Drug Delivery and Translational Research\",\"volume\":\" \",\"pages\":\"874-884\"},\"PeriodicalIF\":5.7000,\"publicationDate\":\"2025-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Drug Delivery and Translational Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s13346-024-01639-1\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drug Delivery and Translational Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s13346-024-01639-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/3 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

一个需要关注的全球性问题是,常规疫苗接种活动所需的针头短缺,而疫苗接种活动所产生的注射器和针头废弃物却呈指数级增长。针对这一问题,本研究提出了一种基于热空化技术的 3D 打印无针注射器。这项工作的重点是研究不同浓度(1-2%)的液体射流与皮肤模型的相互作用,强调其在重复机制中的影响和渗透深度。使用高分辨率 3D 打印机设计并制造了半透明聚合物喷射器,可喷射速度高达约 73 米/秒的液体射流。使用高速摄像机评估了这些射流对皮肤模型的影响。在连续喷射 6 次液体(1% 浓度)后,最大穿透深度约为 2.5 毫米,喷射量约为 4.7 微升。在最高浓度(2.0%)和相同喷射次数的情况下,穿透深度降至约 0.6 毫米,喷射量约为 0.7 微升。这项研究的一个重要发现是,压力最高的液体射流并不会导致最大穿透深度,而是一系列连续射流的结果。此外,喷射射流的速度和形状由溶液量和注射器内形成的半月板决定。这些发现推动了基于热空化技术的精确高效注射器的发展,在医疗和制药领域具有广泛的应用潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

3D printed needleless injector based on thermocavitation: analysis of impact and penetration depth in skin phantoms in a repetitive regime.

3D printed needleless injector based on thermocavitation: analysis of impact and penetration depth in skin phantoms in a repetitive regime.

A global issue that requires attention is the duality between the shortage of needles for regular vaccination campaigns and the exponential increase in syringe and needle waste from such campaigns, which has been exacerbated by the COVID-19 pandemic. In response to this problem, this study presents a 3D printed needleless injector based on thermocavitation. The work focused on investigating the interaction of the resulting liquid jets with skin phantoms at different concentrations (1-2%), emphasizing their impact and penetration depth in a repetitive regime. The injector was designed and fabricated from a semi-transparent polymer using a high-resolution 3D printer, allowing the ejection of liquid jets with velocities up to ~ 73 m/s. The impact of these jets on skin phantoms was evaluated using a high-speed camera. After 6 consecutive liquid jets (1% concentration), a maximum penetration depth of ~ 2.5 mm was achieved, delivering approximately 4.7 µL. For the highest concentration (2.0%) and the same number of shots, the penetration depth was reduced to ~ 0.6 mm with a delivered volume of ~ 0.7 µL. An important finding of this study is that the liquid jet with the highest pressure does not cause the maximum penetration depth, but is the result of a series of successive shots. In addition, the velocity and shape of the ejected jet are determined by the amount of solution and the meniscus formed inside the injector. These findings advance the development of precise and efficient thermocavitation-based injectors with broad potential applications in medical and pharmaceutical fields.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Drug Delivery and Translational Research
Drug Delivery and Translational Research MEDICINE, RESEARCH & EXPERIMENTALPHARMACOL-PHARMACOLOGY & PHARMACY
CiteScore
11.70
自引率
1.90%
发文量
160
期刊介绍: The journal provides a unique forum for scientific publication of high-quality research that is exclusively focused on translational aspects of drug delivery. Rationally developed, effective delivery systems can potentially affect clinical outcome in different disease conditions. Research focused on the following areas of translational drug delivery research will be considered for publication in the journal. Designing and developing novel drug delivery systems, with a focus on their application to disease conditions; Preclinical and clinical data related to drug delivery systems; Drug distribution, pharmacokinetics, clearance, with drug delivery systems as compared to traditional dosing to demonstrate beneficial outcomes Short-term and long-term biocompatibility of drug delivery systems, host response; Biomaterials with growth factors for stem-cell differentiation in regenerative medicine and tissue engineering; Image-guided drug therapy, Nanomedicine; Devices for drug delivery and drug/device combination products. In addition to original full-length papers, communications, and reviews, the journal includes editorials, reports of future meetings, research highlights, and announcements pertaining to the activities of the Controlled Release Society.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信