{"title":"混合全髋关节置换术治疗股骨头软骨下缺损骨折的疗效。","authors":"Suc-Hyun Kweon, Jin Sung Park, Seung Jeong Baek","doi":"10.4055/cios23189","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The purpose of this study was to evaluate functional outcomes, radiologic results, and complications after hybrid total hip arthroplasty (THA) in patients with subchondral insufficiency fractures (SIFs) of the femoral head.</p><p><strong>Methods: </strong>From June 2009 to December 2020, among 985 patients who underwent hybrid THA at our hospital, 19 patients diagnosed with SIF through a retrospective chart review were included. Those under 50 years of age, with radiographic findings of osteonecrosis on the contralateral side of surgery, a history of organ transplantation, and alcohol abuse, were excluded. Functional evaluation was performed using a modified Harris Hip Score (HHS). After surgery, inclination and anteversion of the acetabular cup and version of the femoral system were measured using postoperative x-ray. The outpatient follow-up was performed at 6 weeks, 3 months, 9 months, and 12 months after surgery and every year thereafter. Complications including dislocation, implant loosening, stem subsidence, and periprosthetic infection were observed on follow-up radiographs.</p><p><strong>Results: </strong>The average follow-up time was 29.3 ± 9.1 months (range, 24-64 months) with no loss to follow-up. The mean modified HHS was 83.4 ± 9.6 (range, 65-100) at the last outpatient clinic follow-up. The average inclination of the acetabular cup was 41.9° ± 3.4° (range, 37°-48°), and the anteversion was 27.5° ± 6.7° (range, 18°-39°). The version of the femoral stem was 19° ± 5.7° (range, 12°-29°). There was no case of intraoperative fracture. There were no cases of dislocation, loosening of the cup, subsidence of the femoral stem, intraoperative or periprosthetic fracture, or periprosthetic infection on the follow-up radiographs.</p><p><strong>Conclusions: </strong>In our study, hybrid THA showed favorable outcomes in patients diagnosed with SIF, and there were no further special considerations as for THA performed due to other diseases or fractures.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11130634/pdf/","citationCount":"0","resultStr":"{\"title\":\"Outcomes of Hybrid Total Hip Arthroplasty for Subchondral Insufficiency Fracture of the Femoral Head.\",\"authors\":\"Suc-Hyun Kweon, Jin Sung Park, Seung Jeong Baek\",\"doi\":\"10.4055/cios23189\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The purpose of this study was to evaluate functional outcomes, radiologic results, and complications after hybrid total hip arthroplasty (THA) in patients with subchondral insufficiency fractures (SIFs) of the femoral head.</p><p><strong>Methods: </strong>From June 2009 to December 2020, among 985 patients who underwent hybrid THA at our hospital, 19 patients diagnosed with SIF through a retrospective chart review were included. Those under 50 years of age, with radiographic findings of osteonecrosis on the contralateral side of surgery, a history of organ transplantation, and alcohol abuse, were excluded. Functional evaluation was performed using a modified Harris Hip Score (HHS). After surgery, inclination and anteversion of the acetabular cup and version of the femoral system were measured using postoperative x-ray. The outpatient follow-up was performed at 6 weeks, 3 months, 9 months, and 12 months after surgery and every year thereafter. Complications including dislocation, implant loosening, stem subsidence, and periprosthetic infection were observed on follow-up radiographs.</p><p><strong>Results: </strong>The average follow-up time was 29.3 ± 9.1 months (range, 24-64 months) with no loss to follow-up. The mean modified HHS was 83.4 ± 9.6 (range, 65-100) at the last outpatient clinic follow-up. The average inclination of the acetabular cup was 41.9° ± 3.4° (range, 37°-48°), and the anteversion was 27.5° ± 6.7° (range, 18°-39°). The version of the femoral stem was 19° ± 5.7° (range, 12°-29°). There was no case of intraoperative fracture. There were no cases of dislocation, loosening of the cup, subsidence of the femoral stem, intraoperative or periprosthetic fracture, or periprosthetic infection on the follow-up radiographs.</p><p><strong>Conclusions: </strong>In our study, hybrid THA showed favorable outcomes in patients diagnosed with SIF, and there were no further special considerations as for THA performed due to other diseases or fractures.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11130634/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4055/cios23189\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/13 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4055/cios23189","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/13 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Outcomes of Hybrid Total Hip Arthroplasty for Subchondral Insufficiency Fracture of the Femoral Head.
Background: The purpose of this study was to evaluate functional outcomes, radiologic results, and complications after hybrid total hip arthroplasty (THA) in patients with subchondral insufficiency fractures (SIFs) of the femoral head.
Methods: From June 2009 to December 2020, among 985 patients who underwent hybrid THA at our hospital, 19 patients diagnosed with SIF through a retrospective chart review were included. Those under 50 years of age, with radiographic findings of osteonecrosis on the contralateral side of surgery, a history of organ transplantation, and alcohol abuse, were excluded. Functional evaluation was performed using a modified Harris Hip Score (HHS). After surgery, inclination and anteversion of the acetabular cup and version of the femoral system were measured using postoperative x-ray. The outpatient follow-up was performed at 6 weeks, 3 months, 9 months, and 12 months after surgery and every year thereafter. Complications including dislocation, implant loosening, stem subsidence, and periprosthetic infection were observed on follow-up radiographs.
Results: The average follow-up time was 29.3 ± 9.1 months (range, 24-64 months) with no loss to follow-up. The mean modified HHS was 83.4 ± 9.6 (range, 65-100) at the last outpatient clinic follow-up. The average inclination of the acetabular cup was 41.9° ± 3.4° (range, 37°-48°), and the anteversion was 27.5° ± 6.7° (range, 18°-39°). The version of the femoral stem was 19° ± 5.7° (range, 12°-29°). There was no case of intraoperative fracture. There were no cases of dislocation, loosening of the cup, subsidence of the femoral stem, intraoperative or periprosthetic fracture, or periprosthetic infection on the follow-up radiographs.
Conclusions: In our study, hybrid THA showed favorable outcomes in patients diagnosed with SIF, and there were no further special considerations as for THA performed due to other diseases or fractures.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.