Xavier-François Navick, Jérôme Martignac, Albrecht Poglitsch, Vincent Revéret, Louis Rodriguez, Timothée Tollet, François Visticot
{"title":"用于 B-BOP 摄像机的可调黑体偏振红外光源","authors":"Xavier-François Navick, Jérôme Martignac, Albrecht Poglitsch, Vincent Revéret, Louis Rodriguez, Timothée Tollet, François Visticot","doi":"10.1007/s10909-024-03164-4","DOIUrl":null,"url":null,"abstract":"<div><p>The B-BOP detector is composed of polarization sensitive bolometer arrays in the 70–350 µm spectral range with a goal sensitivity around one attoWatt/sqrt (Hz). A polarized infrared calibration set-up is required to evaluate its performances. The calibration source is based on 6-ring-shaped, concentric blackbody-like emitters that can be individually controlled. The total emitting surface is therefore tunable from 9 up to 1200 mm<sup>2</sup>. The temperature is tunable from 1 to 40 K without disturbing the dilution cryostat and the working temperature of the detector arrays. The present paper describes the source, the rotating polarizer at low temperature, the modulation means, and the complete optical tube leading polarized infrared photons for characterizing detectors down to femtowatt level. Details of the design and realization are discussed.</p></div>","PeriodicalId":641,"journal":{"name":"Journal of Low Temperature Physics","volume":"216 Part 3","pages":"402 - 407"},"PeriodicalIF":1.1000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Tunable Blackbody Polarized Infrared Source for the B-BOP Camera\",\"authors\":\"Xavier-François Navick, Jérôme Martignac, Albrecht Poglitsch, Vincent Revéret, Louis Rodriguez, Timothée Tollet, François Visticot\",\"doi\":\"10.1007/s10909-024-03164-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The B-BOP detector is composed of polarization sensitive bolometer arrays in the 70–350 µm spectral range with a goal sensitivity around one attoWatt/sqrt (Hz). A polarized infrared calibration set-up is required to evaluate its performances. The calibration source is based on 6-ring-shaped, concentric blackbody-like emitters that can be individually controlled. The total emitting surface is therefore tunable from 9 up to 1200 mm<sup>2</sup>. The temperature is tunable from 1 to 40 K without disturbing the dilution cryostat and the working temperature of the detector arrays. The present paper describes the source, the rotating polarizer at low temperature, the modulation means, and the complete optical tube leading polarized infrared photons for characterizing detectors down to femtowatt level. Details of the design and realization are discussed.</p></div>\",\"PeriodicalId\":641,\"journal\":{\"name\":\"Journal of Low Temperature Physics\",\"volume\":\"216 Part 3\",\"pages\":\"402 - 407\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Low Temperature Physics\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s10909-024-03164-4\",\"RegionNum\":3,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PHYSICS, APPLIED\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Low Temperature Physics","FirstCategoryId":"101","ListUrlMain":"https://link.springer.com/article/10.1007/s10909-024-03164-4","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSICS, APPLIED","Score":null,"Total":0}
A Tunable Blackbody Polarized Infrared Source for the B-BOP Camera
The B-BOP detector is composed of polarization sensitive bolometer arrays in the 70–350 µm spectral range with a goal sensitivity around one attoWatt/sqrt (Hz). A polarized infrared calibration set-up is required to evaluate its performances. The calibration source is based on 6-ring-shaped, concentric blackbody-like emitters that can be individually controlled. The total emitting surface is therefore tunable from 9 up to 1200 mm2. The temperature is tunable from 1 to 40 K without disturbing the dilution cryostat and the working temperature of the detector arrays. The present paper describes the source, the rotating polarizer at low temperature, the modulation means, and the complete optical tube leading polarized infrared photons for characterizing detectors down to femtowatt level. Details of the design and realization are discussed.
期刊介绍:
The Journal of Low Temperature Physics publishes original papers and review articles on all areas of low temperature physics and cryogenics, including theoretical and experimental contributions. Subject areas include: Quantum solids, liquids and gases; Superfluidity; Superconductivity; Condensed matter physics; Experimental techniques; The Journal encourages the submission of Rapid Communications and Special Issues.