塑性变形和羟基磷灰石涂层对锌基生物降解合金的结构、机械、腐蚀、抗菌和细胞活力特性的影响

IF 3.3 3区 材料科学 Q2 MATERIALS SCIENCE, MULTIDISCIPLINARY
B. Aksakal, Ege Isın, N. Aslan, S. Cihangir, S. Sezek
{"title":"塑性变形和羟基磷灰石涂层对锌基生物降解合金的结构、机械、腐蚀、抗菌和细胞活力特性的影响","authors":"B. Aksakal, Ege Isın, N. Aslan, S. Cihangir, S. Sezek","doi":"10.1007/s12540-024-01710-z","DOIUrl":null,"url":null,"abstract":"<p>Zinc (Zn)-based biodegradable alloys have been at the forefront of absorbable biomaterial research in recent years due to their high biocompatibility and corrosion rates. The arc melting process was used to produce the Zn–1Cu–1Ag biodegradable alloy. The influence of different plastic deformation rates on the microstructure of the material was examined after the cold rolling at deformation rates of 47% and 61%. The undeformed and deformed alloys have been hydroxyapatite-coated using the electrophoretic deposition process to improve its surface, corrosion, and bioactivity properties. Optical, XRD, SEM, and EDS examinations were used to analyze the samples’ uncoated, coated, and rolled-unrolled forms. The nucleation of the (Ag, Cu)Zn4 secondary phase was formed during the rolling process. Hardness and compression tests were used to determine the mechanical properties of cast and rolled alloys, and in vitro corrosion tests were carried out in simulated body fluid. Antimicrobial and cell viability tests are executed to demonstrate the biocompatibility of the deformed and HA-coated Zn–1Cu–1Ag alloy. The mechanical properties were improved after the rolling process, with the highest results found in 47% of the rolled samples exhibiting a compressive strength of 412.65 ± 0.5 MPa and 61% of the rolled samples exhibiting a hardness value of 88.1 ± 0.5 HV. The samples that were rolled (61%) and coated with hydroxyapatite (HA) exhibited the highest level of corrosion resistance. The antimicrobial tests revealed that the rolled and HA coated Zn1Cu1Ag groups exhibited greater inhibition rates (47 and 61%) compared to the other groups when tested against E. coli. The HA-coated groups exhibited good cell viability ratios, with the maximum viability seen in the rolled and HA-coated group at 47%.</p><h3 data-test=\"abstract-sub-heading\">Graphical Abstract</h3>\n","PeriodicalId":703,"journal":{"name":"Metals and Materials International","volume":"58 1","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2024-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of Plastic Deformation and Hydroxyapatite Coating on Structure, Mechanical, Corrosion, Antibacterial and Cell Viability Properties of Zinc Based Biodegradable Alloys\",\"authors\":\"B. Aksakal, Ege Isın, N. Aslan, S. Cihangir, S. Sezek\",\"doi\":\"10.1007/s12540-024-01710-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Zinc (Zn)-based biodegradable alloys have been at the forefront of absorbable biomaterial research in recent years due to their high biocompatibility and corrosion rates. The arc melting process was used to produce the Zn–1Cu–1Ag biodegradable alloy. The influence of different plastic deformation rates on the microstructure of the material was examined after the cold rolling at deformation rates of 47% and 61%. The undeformed and deformed alloys have been hydroxyapatite-coated using the electrophoretic deposition process to improve its surface, corrosion, and bioactivity properties. Optical, XRD, SEM, and EDS examinations were used to analyze the samples’ uncoated, coated, and rolled-unrolled forms. The nucleation of the (Ag, Cu)Zn4 secondary phase was formed during the rolling process. Hardness and compression tests were used to determine the mechanical properties of cast and rolled alloys, and in vitro corrosion tests were carried out in simulated body fluid. Antimicrobial and cell viability tests are executed to demonstrate the biocompatibility of the deformed and HA-coated Zn–1Cu–1Ag alloy. The mechanical properties were improved after the rolling process, with the highest results found in 47% of the rolled samples exhibiting a compressive strength of 412.65 ± 0.5 MPa and 61% of the rolled samples exhibiting a hardness value of 88.1 ± 0.5 HV. The samples that were rolled (61%) and coated with hydroxyapatite (HA) exhibited the highest level of corrosion resistance. The antimicrobial tests revealed that the rolled and HA coated Zn1Cu1Ag groups exhibited greater inhibition rates (47 and 61%) compared to the other groups when tested against E. coli. The HA-coated groups exhibited good cell viability ratios, with the maximum viability seen in the rolled and HA-coated group at 47%.</p><h3 data-test=\\\"abstract-sub-heading\\\">Graphical Abstract</h3>\\n\",\"PeriodicalId\":703,\"journal\":{\"name\":\"Metals and Materials International\",\"volume\":\"58 1\",\"pages\":\"\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2024-05-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Metals and Materials International\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.1007/s12540-024-01710-z\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metals and Materials International","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1007/s12540-024-01710-z","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

锌(Zn)基可生物降解合金具有较高的生物相容性和腐蚀率,近年来一直处于可吸收生物材料研究的前沿。本文采用电弧熔化工艺生产 Zn-1Cu-1Ag 生物可降解合金。冷轧后,在 47% 和 61% 的变形率下,研究了不同塑性变形率对材料微观结构的影响。利用电泳沉积工艺对未变形和变形合金进行了羟基磷灰石涂层处理,以改善其表面、腐蚀和生物活性特性。利用光学、XRD、SEM 和 EDS 检测分析了样品的未涂层、涂层和轧制-未轧制形态。在轧制过程中形成了(Ag, Cu)Zn4 次生相核。硬度和压缩测试用于确定铸造和轧制合金的机械性能,体外腐蚀测试则在模拟体液中进行。抗菌和细胞活力测试证明了变形和 HA 涂层 Zn-1Cu-1Ag 合金的生物相容性。轧制过程后,机械性能得到改善,最高结果是 47% 的轧制样品的抗压强度达到 412.65 ± 0.5 兆帕,61% 的轧制样品的硬度值达到 88.1 ± 0.5 HV。经过轧制(61%)并涂有羟基磷灰石(HA)的样品具有最高的耐腐蚀性。抗菌测试表明,在对大肠杆菌进行测试时,轧制和涂有羟基磷灰石(HA)的 Zn1Cu1Ag 组比其他组具有更高的抑制率(47% 和 61%)。HA涂层组显示出良好的细胞存活率,其中轧制和HA涂层组的细胞存活率最高,为47%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Influence of Plastic Deformation and Hydroxyapatite Coating on Structure, Mechanical, Corrosion, Antibacterial and Cell Viability Properties of Zinc Based Biodegradable Alloys

Influence of Plastic Deformation and Hydroxyapatite Coating on Structure, Mechanical, Corrosion, Antibacterial and Cell Viability Properties of Zinc Based Biodegradable Alloys

Zinc (Zn)-based biodegradable alloys have been at the forefront of absorbable biomaterial research in recent years due to their high biocompatibility and corrosion rates. The arc melting process was used to produce the Zn–1Cu–1Ag biodegradable alloy. The influence of different plastic deformation rates on the microstructure of the material was examined after the cold rolling at deformation rates of 47% and 61%. The undeformed and deformed alloys have been hydroxyapatite-coated using the electrophoretic deposition process to improve its surface, corrosion, and bioactivity properties. Optical, XRD, SEM, and EDS examinations were used to analyze the samples’ uncoated, coated, and rolled-unrolled forms. The nucleation of the (Ag, Cu)Zn4 secondary phase was formed during the rolling process. Hardness and compression tests were used to determine the mechanical properties of cast and rolled alloys, and in vitro corrosion tests were carried out in simulated body fluid. Antimicrobial and cell viability tests are executed to demonstrate the biocompatibility of the deformed and HA-coated Zn–1Cu–1Ag alloy. The mechanical properties were improved after the rolling process, with the highest results found in 47% of the rolled samples exhibiting a compressive strength of 412.65 ± 0.5 MPa and 61% of the rolled samples exhibiting a hardness value of 88.1 ± 0.5 HV. The samples that were rolled (61%) and coated with hydroxyapatite (HA) exhibited the highest level of corrosion resistance. The antimicrobial tests revealed that the rolled and HA coated Zn1Cu1Ag groups exhibited greater inhibition rates (47 and 61%) compared to the other groups when tested against E. coli. The HA-coated groups exhibited good cell viability ratios, with the maximum viability seen in the rolled and HA-coated group at 47%.

Graphical Abstract

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Metals and Materials International
Metals and Materials International 工程技术-材料科学:综合
CiteScore
7.10
自引率
8.60%
发文量
197
审稿时长
3.7 months
期刊介绍: Metals and Materials International publishes original papers and occasional critical reviews on all aspects of research and technology in materials engineering: physical metallurgy, materials science, and processing of metals and other materials. Emphasis is placed on those aspects of the science of materials that are concerned with the relationships among the processing, structure and properties (mechanical, chemical, electrical, electrochemical, magnetic and optical) of materials. Aspects of processing include the melting, casting, and fabrication with the thermodynamics, kinetics and modeling.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信