多磁体人工耳蜗技术与磁共振成像:安全问题。

IF 2.1 Q1 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY
Pietro Canzi, Elena Carlotto, Elisabetta Zanoletti, Johan H M Frijns, Daniele Borsetto, Antonio Caruso, Luisa Chiapparini, Andrea Ciorba, Giorgio Conte, Nathan Creber, Stefania Criscuolo, Filippo Di Lella, Sebastiano Franchella, Erik F Hensen, Lorenzo Lauda, Stefano Malpede, Marco Mandalà, Liselotte J C Rotteveel, Anna Simoncelli, Anna Chiara Stellato, Diego Zanetti, Marco Benazzo
{"title":"多磁体人工耳蜗技术与磁共振成像:安全问题。","authors":"Pietro Canzi, Elena Carlotto, Elisabetta Zanoletti, Johan H M Frijns, Daniele Borsetto, Antonio Caruso, Luisa Chiapparini, Andrea Ciorba, Giorgio Conte, Nathan Creber, Stefania Criscuolo, Filippo Di Lella, Sebastiano Franchella, Erik F Hensen, Lorenzo Lauda, Stefano Malpede, Marco Mandalà, Liselotte J C Rotteveel, Anna Simoncelli, Anna Chiara Stellato, Diego Zanetti, Marco Benazzo","doi":"10.3390/audiolres14030034","DOIUrl":null,"url":null,"abstract":"<p><p>Despite the spread of novel-generation cochlear-implant (CI) magnetic systems, access to magnetic resonance imaging (MRI) for CI recipients is still limited due to safety concerns. The aim of this study is to assess and record the experiences of Hires Ultra 3D (Advanced Bionics) recipients who underwent an MRI examination. A multicentric European survey about this topic was conducted focusing on safety issues, and the results were compared with the current literature. We collected a total of 65 MRI scans performed in 9 otologic referral centers for a total of 47 Hires Ultra 3D recipients, including, for the first time, 2 children and 3 teenagers. Preventive measures were represented by scanning time and sedation for children. Head wrapping was used in eight cases, and six of the eight cases received local anesthesia, even if both measures were not needed. Only three patients complained of pain (3/65 examinations, 4.6%) due to the tight head bandage, and one of the three cases required MRI scan interruption. No other adverse events were reported. We believe that these results should encourage MRI execution in accordance with manufacturer recommendations for Ultra 3D recipients.</p>","PeriodicalId":44133,"journal":{"name":"Audiology Research","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11130805/pdf/","citationCount":"0","resultStr":"{\"title\":\"Multi-Magnet Cochlear Implant Technology and Magnetic Resonance Imaging: The Safety Issue.\",\"authors\":\"Pietro Canzi, Elena Carlotto, Elisabetta Zanoletti, Johan H M Frijns, Daniele Borsetto, Antonio Caruso, Luisa Chiapparini, Andrea Ciorba, Giorgio Conte, Nathan Creber, Stefania Criscuolo, Filippo Di Lella, Sebastiano Franchella, Erik F Hensen, Lorenzo Lauda, Stefano Malpede, Marco Mandalà, Liselotte J C Rotteveel, Anna Simoncelli, Anna Chiara Stellato, Diego Zanetti, Marco Benazzo\",\"doi\":\"10.3390/audiolres14030034\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Despite the spread of novel-generation cochlear-implant (CI) magnetic systems, access to magnetic resonance imaging (MRI) for CI recipients is still limited due to safety concerns. The aim of this study is to assess and record the experiences of Hires Ultra 3D (Advanced Bionics) recipients who underwent an MRI examination. A multicentric European survey about this topic was conducted focusing on safety issues, and the results were compared with the current literature. We collected a total of 65 MRI scans performed in 9 otologic referral centers for a total of 47 Hires Ultra 3D recipients, including, for the first time, 2 children and 3 teenagers. Preventive measures were represented by scanning time and sedation for children. Head wrapping was used in eight cases, and six of the eight cases received local anesthesia, even if both measures were not needed. Only three patients complained of pain (3/65 examinations, 4.6%) due to the tight head bandage, and one of the three cases required MRI scan interruption. No other adverse events were reported. We believe that these results should encourage MRI execution in accordance with manufacturer recommendations for Ultra 3D recipients.</p>\",\"PeriodicalId\":44133,\"journal\":{\"name\":\"Audiology Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-04-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11130805/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Audiology Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/audiolres14030034\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Audiology Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/audiolres14030034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

尽管新一代人工耳蜗(CI)磁力系统已经普及,但出于安全考虑,CI 植入者接受磁共振成像(MRI)检查的机会仍然有限。本研究旨在评估和记录希尔思 Ultra 3D(Advanced Bionics)受术者接受磁共振成像检查的经历。我们就这一主题开展了一项欧洲多中心调查,重点关注安全性问题,并将调查结果与现有文献进行了比较。我们共收集了在 9 家耳科转诊中心为 47 名 Hires Ultra 3D 受术者进行的 65 次核磁共振扫描,其中首次包括 2 名儿童和 3 名青少年。预防措施包括扫描时间和儿童镇静剂。有 8 例患者使用了头部包裹,8 例中有 6 例接受了局部麻醉,即使这两种措施都不需要。只有三名患者抱怨头部包扎过紧导致疼痛(3/65,4.6%),其中一名患者需要中断磁共振成像扫描。没有其他不良事件的报告。我们认为,这些结果应鼓励 Ultra 3D 接受者按照制造商的建议执行核磁共振成像。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Multi-Magnet Cochlear Implant Technology and Magnetic Resonance Imaging: The Safety Issue.

Despite the spread of novel-generation cochlear-implant (CI) magnetic systems, access to magnetic resonance imaging (MRI) for CI recipients is still limited due to safety concerns. The aim of this study is to assess and record the experiences of Hires Ultra 3D (Advanced Bionics) recipients who underwent an MRI examination. A multicentric European survey about this topic was conducted focusing on safety issues, and the results were compared with the current literature. We collected a total of 65 MRI scans performed in 9 otologic referral centers for a total of 47 Hires Ultra 3D recipients, including, for the first time, 2 children and 3 teenagers. Preventive measures were represented by scanning time and sedation for children. Head wrapping was used in eight cases, and six of the eight cases received local anesthesia, even if both measures were not needed. Only three patients complained of pain (3/65 examinations, 4.6%) due to the tight head bandage, and one of the three cases required MRI scan interruption. No other adverse events were reported. We believe that these results should encourage MRI execution in accordance with manufacturer recommendations for Ultra 3D recipients.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Audiology Research
Audiology Research AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY-
CiteScore
2.30
自引率
23.50%
发文量
56
审稿时长
11 weeks
期刊介绍: The mission of Audiology Research is to publish contemporary, ethical, clinically relevant scientific researches related to the basic science and clinical aspects of the auditory and vestibular system and diseases of the ear that can be used by clinicians, scientists and specialists to improve understanding and treatment of patients with audiological and neurotological disorders.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信