重症监护室中心脏骤停时护理点超声波的使用:横断面调查。

IF 2.6 3区 医学 Q2 CRITICAL CARE MEDICINE
Australian Critical Care Pub Date : 2025-01-01 Epub Date: 2024-05-25 DOI:10.1016/j.aucc.2024.04.003
David A West, Caroline Killick, Daryl Jones
{"title":"重症监护室中心脏骤停时护理点超声波的使用:横断面调查。","authors":"David A West, Caroline Killick, Daryl Jones","doi":"10.1016/j.aucc.2024.04.003","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>There is growing interest in the use of point-of-care ultrasound during cardiac arrest, but few studies document its use in the intensive care unit.</p><p><strong>Objective: </strong>We hypothesised this may reflect a low prevalence of use of point-of-care ultrasound during cardiac arrest or negative attitudes towards its use. We aimed to determine the self-reported prevalence, attitudes towards, and barriers to use of point-of-care ultrasound during cardiac arrest in the intensive care unit.</p><p><strong>Methods: </strong>We conducted a web-based survey over 3 months (08/08/2022-06/11/2022), of intensive care unit consultants and registrars in Victoria, Australia. Descriptive and mixed-methods analyses of Likert-type and free-text answers were performed.</p><p><strong>Results: </strong>The response rate was 91/398 (22.8%), split evenly between consultants and registrars. There was a broad range of clinical and ultrasound experience. Only 22.4% (22/91) of respondents reported using point-of-care ultrasound 75-100% of the time during their management of cardiac arrest. Respondents rated the value they place in point-of-care ultrasound during cardiac arrest 3 (interquartile range: 3-4) and that of a \"skilled operator\" 4 ((interquartile range; 4-5) on a 5-point scale. Free-text analysis suggested exclusion of \"tamponade\" (40/80 [50%] comments) as the most valuable use-case and \"skill\" as a personal barrier (20/73 [27.4%] comments). Personal and departmental barriers were not rated highly, although registrars perceived \"lack of a structured training program\" as a barrier. Respondents were equivocal in the value they gave point-of-care ultrasound during cardiac arrest but saw greater value when conducted by a skilled operator.</p><p><strong>Conclusions: </strong>Point-of-care ultrasound was reported to be infrequently used in cardiac arrest, mostly due to self-perceived skill and lack of a structured training program.</p>","PeriodicalId":51239,"journal":{"name":"Australian Critical Care","volume":" ","pages":"101058"},"PeriodicalIF":2.6000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Use of point-of-care ultrasound during cardiac arrest in the intensive care unit: A cross-sectional survey.\",\"authors\":\"David A West, Caroline Killick, Daryl Jones\",\"doi\":\"10.1016/j.aucc.2024.04.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>There is growing interest in the use of point-of-care ultrasound during cardiac arrest, but few studies document its use in the intensive care unit.</p><p><strong>Objective: </strong>We hypothesised this may reflect a low prevalence of use of point-of-care ultrasound during cardiac arrest or negative attitudes towards its use. We aimed to determine the self-reported prevalence, attitudes towards, and barriers to use of point-of-care ultrasound during cardiac arrest in the intensive care unit.</p><p><strong>Methods: </strong>We conducted a web-based survey over 3 months (08/08/2022-06/11/2022), of intensive care unit consultants and registrars in Victoria, Australia. Descriptive and mixed-methods analyses of Likert-type and free-text answers were performed.</p><p><strong>Results: </strong>The response rate was 91/398 (22.8%), split evenly between consultants and registrars. There was a broad range of clinical and ultrasound experience. Only 22.4% (22/91) of respondents reported using point-of-care ultrasound 75-100% of the time during their management of cardiac arrest. Respondents rated the value they place in point-of-care ultrasound during cardiac arrest 3 (interquartile range: 3-4) and that of a \\\"skilled operator\\\" 4 ((interquartile range; 4-5) on a 5-point scale. Free-text analysis suggested exclusion of \\\"tamponade\\\" (40/80 [50%] comments) as the most valuable use-case and \\\"skill\\\" as a personal barrier (20/73 [27.4%] comments). Personal and departmental barriers were not rated highly, although registrars perceived \\\"lack of a structured training program\\\" as a barrier. Respondents were equivocal in the value they gave point-of-care ultrasound during cardiac arrest but saw greater value when conducted by a skilled operator.</p><p><strong>Conclusions: </strong>Point-of-care ultrasound was reported to be infrequently used in cardiac arrest, mostly due to self-perceived skill and lack of a structured training program.</p>\",\"PeriodicalId\":51239,\"journal\":{\"name\":\"Australian Critical Care\",\"volume\":\" \",\"pages\":\"101058\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Australian Critical Care\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.aucc.2024.04.003\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/25 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"CRITICAL CARE MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Australian Critical Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.aucc.2024.04.003","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/25 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景:人们对在心脏骤停期间使用护理点超声波的兴趣与日俱增,但很少有研究记录其在重症监护病房的使用情况:我们假设这可能反映出在心脏骤停期间护理点超声波的使用率较低或对其使用持消极态度。我们的目的是确定重症监护病房在心脏骤停期间使用护理点超声波的自我报告流行率、使用态度和障碍:我们对澳大利亚维多利亚州的重症监护室顾问和注册医师进行了为期 3 个月(8/08/2022-06/11/2022)的网络调查。对李克特类型和自由文本答案进行了描述性和混合方法分析:回复率为 91/398(22.8%),顾问和注册医师各占一半。临床经验和超声经验的范围很广。只有 22.4%(22/91)的受访者表示在处理心脏骤停的过程中,75%-100% 的时间都在使用床旁超声。受访者对心脏骤停时护理点超声波的价值评价为 3(四分位数间距:3-4)分,对 "熟练操作者 "的价值评价为 4(四分位数间距:4-5)分(5 分)。自由文本分析表明,"填塞"(40/80 [50%] 条评论)被排除在最有价值的使用案例之外,而 "技能 "则是个人障碍(20/73 [27.4%] 条评论)。虽然注册医师认为 "缺乏结构化培训计划 "是一个障碍,但个人和部门障碍的评价并不高。受访者对心脏骤停期间护理点超声波的价值评价不一,但认为由熟练操作者进行护理点超声波的价值更大:结论:据报道,在心脏骤停中很少使用护理点超声波,这主要是由于自我感觉的技能和缺乏结构化的培训计划。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Use of point-of-care ultrasound during cardiac arrest in the intensive care unit: A cross-sectional survey.

Background: There is growing interest in the use of point-of-care ultrasound during cardiac arrest, but few studies document its use in the intensive care unit.

Objective: We hypothesised this may reflect a low prevalence of use of point-of-care ultrasound during cardiac arrest or negative attitudes towards its use. We aimed to determine the self-reported prevalence, attitudes towards, and barriers to use of point-of-care ultrasound during cardiac arrest in the intensive care unit.

Methods: We conducted a web-based survey over 3 months (08/08/2022-06/11/2022), of intensive care unit consultants and registrars in Victoria, Australia. Descriptive and mixed-methods analyses of Likert-type and free-text answers were performed.

Results: The response rate was 91/398 (22.8%), split evenly between consultants and registrars. There was a broad range of clinical and ultrasound experience. Only 22.4% (22/91) of respondents reported using point-of-care ultrasound 75-100% of the time during their management of cardiac arrest. Respondents rated the value they place in point-of-care ultrasound during cardiac arrest 3 (interquartile range: 3-4) and that of a "skilled operator" 4 ((interquartile range; 4-5) on a 5-point scale. Free-text analysis suggested exclusion of "tamponade" (40/80 [50%] comments) as the most valuable use-case and "skill" as a personal barrier (20/73 [27.4%] comments). Personal and departmental barriers were not rated highly, although registrars perceived "lack of a structured training program" as a barrier. Respondents were equivocal in the value they gave point-of-care ultrasound during cardiac arrest but saw greater value when conducted by a skilled operator.

Conclusions: Point-of-care ultrasound was reported to be infrequently used in cardiac arrest, mostly due to self-perceived skill and lack of a structured training program.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Australian Critical Care
Australian Critical Care NURSING-NURSING
CiteScore
4.90
自引率
9.10%
发文量
148
审稿时长
>12 weeks
期刊介绍: Australian Critical Care is the official journal of the Australian College of Critical Care Nurses (ACCCN). It is a bi-monthly peer-reviewed journal, providing clinically relevant research, reviews and articles of interest to the critical care community. Australian Critical Care publishes peer-reviewed scholarly papers that report research findings, research-based reviews, discussion papers and commentaries which are of interest to an international readership of critical care practitioners, educators, administrators and researchers. Interprofessional articles are welcomed.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信