Changkuan Liang, Dazhuang He, Haotian Liu, Jinwoo Oh, James E. Braun, Eckhard A. Groll, Davide Ziviani
{"title":"对使用 R600a 的柔性三蒸发器家用冰箱/冰柜进行综合节能的研究","authors":"Changkuan Liang, Dazhuang He, Haotian Liu, Jinwoo Oh, James E. Braun, Eckhard A. Groll, Davide Ziviani","doi":"10.1016/j.ijrefrig.2024.05.029","DOIUrl":null,"url":null,"abstract":"<div><p>Domestic refrigerator/freezers account for approximately 6 % of all energy consumption around the globe and mainly rely on vapor compression cycles to operate. Researchers have investigated alternative cycle architectures such as dual-loop cycles and parallel circuit cycles to improve their efficiencies. Despite the demonstrated energy saving potential of these advanced cycles, additional implementation costs are often not justifiable. However, to meet forthcoming stricter energy standards while ensuring flexible multi-temperature operation of domestic refrigerator/freezers, advanced cycle architectures are needed. In this paper, a state-of-the-art bypass circuit cycle triple-evaporator domestic refrigerator freezer with R-600a and a reciprocating compressor has been used as the baseline cycle investigate an alternative cycle configuration. Specifically, this work presents a two-stage vapor-injected cycle with a multi-evaporator system to enable energy savings and cost-effectiveness. The cycle establishes two separate evaporation temperatures to better match the cabinet temperature of fresh food and freezer compartment. The reduced difference between cabinet temperature and its evaporation temperature decreases the irreversibilities in the heat exchanger and improves overall system efficiency. Moreover, the addition of the economization line from the medium temperature evaporator reduces the compressor work. To capture the complex transient behavior of both the baseline system and proposed cycle architecture with their control strategies, a dynamic model has been developed and validated with experimental data. The validated dynamic model with the baseline cycle was modified to consider the two-stage vapor-injected cycle and its control logic, and simulation results yielded up to 13 % energy consumption reduction with respect to the baseline system.</p></div>","PeriodicalId":14274,"journal":{"name":"International Journal of Refrigeration-revue Internationale Du Froid","volume":null,"pages":null},"PeriodicalIF":3.5000,"publicationDate":"2024-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation of a flexible triple-evaporator domestic refrigerator/freezer with R600a with integrated economization\",\"authors\":\"Changkuan Liang, Dazhuang He, Haotian Liu, Jinwoo Oh, James E. Braun, Eckhard A. Groll, Davide Ziviani\",\"doi\":\"10.1016/j.ijrefrig.2024.05.029\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Domestic refrigerator/freezers account for approximately 6 % of all energy consumption around the globe and mainly rely on vapor compression cycles to operate. Researchers have investigated alternative cycle architectures such as dual-loop cycles and parallel circuit cycles to improve their efficiencies. Despite the demonstrated energy saving potential of these advanced cycles, additional implementation costs are often not justifiable. However, to meet forthcoming stricter energy standards while ensuring flexible multi-temperature operation of domestic refrigerator/freezers, advanced cycle architectures are needed. In this paper, a state-of-the-art bypass circuit cycle triple-evaporator domestic refrigerator freezer with R-600a and a reciprocating compressor has been used as the baseline cycle investigate an alternative cycle configuration. Specifically, this work presents a two-stage vapor-injected cycle with a multi-evaporator system to enable energy savings and cost-effectiveness. The cycle establishes two separate evaporation temperatures to better match the cabinet temperature of fresh food and freezer compartment. The reduced difference between cabinet temperature and its evaporation temperature decreases the irreversibilities in the heat exchanger and improves overall system efficiency. Moreover, the addition of the economization line from the medium temperature evaporator reduces the compressor work. To capture the complex transient behavior of both the baseline system and proposed cycle architecture with their control strategies, a dynamic model has been developed and validated with experimental data. The validated dynamic model with the baseline cycle was modified to consider the two-stage vapor-injected cycle and its control logic, and simulation results yielded up to 13 % energy consumption reduction with respect to the baseline system.</p></div>\",\"PeriodicalId\":14274,\"journal\":{\"name\":\"International Journal of Refrigeration-revue Internationale Du Froid\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2024-05-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Refrigeration-revue Internationale Du Froid\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0140700724001890\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Refrigeration-revue Internationale Du Froid","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0140700724001890","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
Investigation of a flexible triple-evaporator domestic refrigerator/freezer with R600a with integrated economization
Domestic refrigerator/freezers account for approximately 6 % of all energy consumption around the globe and mainly rely on vapor compression cycles to operate. Researchers have investigated alternative cycle architectures such as dual-loop cycles and parallel circuit cycles to improve their efficiencies. Despite the demonstrated energy saving potential of these advanced cycles, additional implementation costs are often not justifiable. However, to meet forthcoming stricter energy standards while ensuring flexible multi-temperature operation of domestic refrigerator/freezers, advanced cycle architectures are needed. In this paper, a state-of-the-art bypass circuit cycle triple-evaporator domestic refrigerator freezer with R-600a and a reciprocating compressor has been used as the baseline cycle investigate an alternative cycle configuration. Specifically, this work presents a two-stage vapor-injected cycle with a multi-evaporator system to enable energy savings and cost-effectiveness. The cycle establishes two separate evaporation temperatures to better match the cabinet temperature of fresh food and freezer compartment. The reduced difference between cabinet temperature and its evaporation temperature decreases the irreversibilities in the heat exchanger and improves overall system efficiency. Moreover, the addition of the economization line from the medium temperature evaporator reduces the compressor work. To capture the complex transient behavior of both the baseline system and proposed cycle architecture with their control strategies, a dynamic model has been developed and validated with experimental data. The validated dynamic model with the baseline cycle was modified to consider the two-stage vapor-injected cycle and its control logic, and simulation results yielded up to 13 % energy consumption reduction with respect to the baseline system.
期刊介绍:
The International Journal of Refrigeration is published for the International Institute of Refrigeration (IIR) by Elsevier. It is essential reading for all those wishing to keep abreast of research and industrial news in refrigeration, air conditioning and associated fields. This is particularly important in these times of rapid introduction of alternative refrigerants and the emergence of new technology. The journal has published special issues on alternative refrigerants and novel topics in the field of boiling, condensation, heat pumps, food refrigeration, carbon dioxide, ammonia, hydrocarbons, magnetic refrigeration at room temperature, sorptive cooling, phase change materials and slurries, ejector technology, compressors, and solar cooling.
As well as original research papers the International Journal of Refrigeration also includes review articles, papers presented at IIR conferences, short reports and letters describing preliminary results and experimental details, and letters to the Editor on recent areas of discussion and controversy. Other features include forthcoming events, conference reports and book reviews.
Papers are published in either English or French with the IIR news section in both languages.