用 B 型超声波测量腮腺横截面积的可靠性

IF 2.2 3区 医学 Q1 OTORHINOLARYNGOLOGY
Dysphagia Pub Date : 2025-02-01 Epub Date: 2024-05-24 DOI:10.1007/s00455-024-10712-3
Barbara R Pauloski, Kacey M Yahnke
{"title":"用 B 型超声波测量腮腺横截面积的可靠性","authors":"Barbara R Pauloski, Kacey M Yahnke","doi":"10.1007/s00455-024-10712-3","DOIUrl":null,"url":null,"abstract":"<p><p>B-mode ultrasound is a safe noninvasive procedure that has been used to characterize aspects of the oropharyngeal swallow. The submental suprahyoid muscles are often investigated with ultrasound because of their contributions to hyolaryngeal elevation. There are several techniques for positioning the ultrasound transducer in the coronal plane, however, there is limited research on how reliability of measurement of the cross-sectional area (CSA) of the geniohyoid differs across transducer placement technique. This study examined three methods of transducer placement in the coronal plane by two examiners to determine the reliability of measurement of CSA of the geniohyoid muscle. Forty healthy adults participated in the study. Each participant's geniohyoid muscles were imaged using B-mode ultrasound under three transducer placement conditions in the coronal plane by two examiners. Geniohyoid CSA was measured from each ultrasound image. A three-way mixed-methods ANOVA was used to determine whether there were significant differences in geniohyoid CSA among transducer position conditions, trials, and examiners. There were significant differences among the transducer placement conditions, indicating that each condition was measuring a different portion of the muscle. There were no significant differences among repeated trials nor between examiners within each method of transducer placement. All three conditions of transducer placement were reliable at measuring geniohyoid CSA across trials and examiners. This study emphasizes the need for consistency of placement, whichever method is selected. It also highlights the need for researchers to provide a precise description of methods for positioning the transducer so that placement is reproducible.</p>","PeriodicalId":11508,"journal":{"name":"Dysphagia","volume":" ","pages":"141-151"},"PeriodicalIF":2.2000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reliability of Measuring Geniohyoid Cross-Sectional Area with B-Mode Ultrasound.\",\"authors\":\"Barbara R Pauloski, Kacey M Yahnke\",\"doi\":\"10.1007/s00455-024-10712-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>B-mode ultrasound is a safe noninvasive procedure that has been used to characterize aspects of the oropharyngeal swallow. The submental suprahyoid muscles are often investigated with ultrasound because of their contributions to hyolaryngeal elevation. There are several techniques for positioning the ultrasound transducer in the coronal plane, however, there is limited research on how reliability of measurement of the cross-sectional area (CSA) of the geniohyoid differs across transducer placement technique. This study examined three methods of transducer placement in the coronal plane by two examiners to determine the reliability of measurement of CSA of the geniohyoid muscle. Forty healthy adults participated in the study. Each participant's geniohyoid muscles were imaged using B-mode ultrasound under three transducer placement conditions in the coronal plane by two examiners. Geniohyoid CSA was measured from each ultrasound image. A three-way mixed-methods ANOVA was used to determine whether there were significant differences in geniohyoid CSA among transducer position conditions, trials, and examiners. There were significant differences among the transducer placement conditions, indicating that each condition was measuring a different portion of the muscle. There were no significant differences among repeated trials nor between examiners within each method of transducer placement. All three conditions of transducer placement were reliable at measuring geniohyoid CSA across trials and examiners. This study emphasizes the need for consistency of placement, whichever method is selected. It also highlights the need for researchers to provide a precise description of methods for positioning the transducer so that placement is reproducible.</p>\",\"PeriodicalId\":11508,\"journal\":{\"name\":\"Dysphagia\",\"volume\":\" \",\"pages\":\"141-151\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2025-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dysphagia\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00455-024-10712-3\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/24 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"OTORHINOLARYNGOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dysphagia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00455-024-10712-3","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/24 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

B 型超声波是一种安全的无创检查方法,已被用于描述口咽吞咽的各个方面。由于下颌舌骨上肌对舌咽抬高有一定的作用,因此经常使用超声波检查下颌舌骨上肌。在冠状面上定位超声波换能器的技术有多种,但是,关于不同换能器定位技术对测得舌骨横截面积(CSA)的可靠性有何不同的研究却很有限。本研究考察了两名检查者在冠状面上放置探头的三种方法,以确定测量舌骨肌横截面积的可靠性。40 名健康成年人参加了这项研究。在冠状面上的三种换能器放置条件下,由两名检查人员使用 B 型超声波对每位参与者的舌骨肌进行成像。根据每张超声波图像测量膝状肌CSA。采用三方混合方差分析来确定在不同的换能器位置条件、试验和检查者之间,膝状肌CSA是否存在显著差异。探头位置条件之间存在明显差异,表明每种条件测量的是肌肉的不同部分。在每种传感器放置方法中,重复试验之间或检查者之间没有明显差异。在不同的试验和检查者之间,所有三种传感器放置条件在测量舌侧肌CSA方面都是可靠的。这项研究强调,无论选择哪种方法,都需要保持放置位置的一致性。它还强调了研究人员对传感器定位方法进行精确描述的必要性,以便使定位具有可重复性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Reliability of Measuring Geniohyoid Cross-Sectional Area with B-Mode Ultrasound.

Reliability of Measuring Geniohyoid Cross-Sectional Area with B-Mode Ultrasound.

B-mode ultrasound is a safe noninvasive procedure that has been used to characterize aspects of the oropharyngeal swallow. The submental suprahyoid muscles are often investigated with ultrasound because of their contributions to hyolaryngeal elevation. There are several techniques for positioning the ultrasound transducer in the coronal plane, however, there is limited research on how reliability of measurement of the cross-sectional area (CSA) of the geniohyoid differs across transducer placement technique. This study examined three methods of transducer placement in the coronal plane by two examiners to determine the reliability of measurement of CSA of the geniohyoid muscle. Forty healthy adults participated in the study. Each participant's geniohyoid muscles were imaged using B-mode ultrasound under three transducer placement conditions in the coronal plane by two examiners. Geniohyoid CSA was measured from each ultrasound image. A three-way mixed-methods ANOVA was used to determine whether there were significant differences in geniohyoid CSA among transducer position conditions, trials, and examiners. There were significant differences among the transducer placement conditions, indicating that each condition was measuring a different portion of the muscle. There were no significant differences among repeated trials nor between examiners within each method of transducer placement. All three conditions of transducer placement were reliable at measuring geniohyoid CSA across trials and examiners. This study emphasizes the need for consistency of placement, whichever method is selected. It also highlights the need for researchers to provide a precise description of methods for positioning the transducer so that placement is reproducible.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Dysphagia
Dysphagia 医学-耳鼻喉科学
CiteScore
4.90
自引率
15.40%
发文量
149
审稿时长
6-12 weeks
期刊介绍: Dysphagia aims to serve as a voice for the benefit of the patient. The journal is devoted exclusively to swallowing and its disorders. The purpose of the journal is to provide a source of information to the flourishing dysphagia community. Over the past years, the field of dysphagia has grown rapidly, and the community of dysphagia researchers have galvanized with ambition to represent dysphagia patients. In addition to covering a myriad of disciplines in medicine and speech pathology, the following topics are also covered, but are not limited to: bio-engineering, deglutition, esophageal motility, immunology, and neuro-gastroenterology. The journal aims to foster a growing need for further dysphagia investigation, to disseminate knowledge through research, and to stimulate communication among interested professionals. The journal publishes original papers, technical and instrumental notes, letters to the editor, and review articles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信