冯-威廉因子糖蛋白 IbM 活性自动测定法与三种替代冯-威廉因子活性测定法的比较评估

IF 3.4 3区 医学 Q2 HEMATOLOGY
Kenneth D. Friedman , Martina Böhm-Weigert , Nicole DeSimone , Dennis J. Dietzen , Charles Eby , Cynthia Flickinger , Walter Hoyer , Mareike Kahl , Kandice Kottke-Marchant , Thomas L. Ortel , Jürgen Patzke , Steven W. Pipe , Morgan Stuart , Ayse Anil Timur , Ravindra Sarode
{"title":"冯-威廉因子糖蛋白 IbM 活性自动测定法与三种替代冯-威廉因子活性测定法的比较评估","authors":"Kenneth D. Friedman ,&nbsp;Martina Böhm-Weigert ,&nbsp;Nicole DeSimone ,&nbsp;Dennis J. Dietzen ,&nbsp;Charles Eby ,&nbsp;Cynthia Flickinger ,&nbsp;Walter Hoyer ,&nbsp;Mareike Kahl ,&nbsp;Kandice Kottke-Marchant ,&nbsp;Thomas L. Ortel ,&nbsp;Jürgen Patzke ,&nbsp;Steven W. Pipe ,&nbsp;Morgan Stuart ,&nbsp;Ayse Anil Timur ,&nbsp;Ravindra Sarode","doi":"10.1016/j.rpth.2024.102422","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>To overcome deficiencies of the traditional von Willebrand factor (VWF) ristocetin cofactor activity assay (VWF:RCo), several automated assays for VWF platelet-binding activity have been developed. Information on the performance of these assays and their diagnostic utility remains limited.</p></div><div><h3>Objectives</h3><p>To validate the VWF:glycoprotein IbM assay INNOVANCE VWF Ac and compare it with an automated VWF:RCo assay as well as with an automated assay and a manual VWF:Ab assay and to generate reference ranges and analyze reproducibility of the VWF:glycoprotein IbM assay.</p></div><div><h3>Methods</h3><p>Clinical sites enrolled healthy subjects and patients representing the intended use population; VWF activity assays were performed, and results were analyzed. The performance of the INNOVANCE VWF Ac assay was also compared between the BCS XP System and the CS-2500 and CS-5100 analyzers.</p></div><div><h3>Results</h3><p>The INNOVANCE VWF Ac assay correlated well with the VWF:RCo assay and the automated HemosIL VWF:Ab assay, with Pearson coefficients of &gt;.9 and a predicted bias of ≤5.0 IU/dL at VWF levels of 30 IU/dL and ≤5.8 IU/dL at the levels of 50 IU/dL, but correlation and bias were not as good when compared with the REAADS manual VWF:Ab assay. Reference ranges observed for healthy subjects correlated well with previously published findings. Reproducibility of the INNOVANCE VWF Ac assay on the BCS XP System and the CS analyzers was excellent, as was correlation among devices.</p></div><div><h3>Conclusion</h3><p>The characteristics of the INNOVANCE VWF Ac assay regarding comparability with other VWF activity assays, reference ranges, and precision support the use of this assay for evaluation of patients with concern for von Willebrand disease.</p></div>","PeriodicalId":20893,"journal":{"name":"Research and Practice in Thrombosis and Haemostasis","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2475037924001110/pdfft?md5=20f738306f5b1fbfde470ff1cf36ae5b&pid=1-s2.0-S2475037924001110-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Evaluation of an automated von Willebrand factor glycoprotein IbM activity assay compared with 3 alternative von Willebrand factor activity assays\",\"authors\":\"Kenneth D. Friedman ,&nbsp;Martina Böhm-Weigert ,&nbsp;Nicole DeSimone ,&nbsp;Dennis J. Dietzen ,&nbsp;Charles Eby ,&nbsp;Cynthia Flickinger ,&nbsp;Walter Hoyer ,&nbsp;Mareike Kahl ,&nbsp;Kandice Kottke-Marchant ,&nbsp;Thomas L. Ortel ,&nbsp;Jürgen Patzke ,&nbsp;Steven W. Pipe ,&nbsp;Morgan Stuart ,&nbsp;Ayse Anil Timur ,&nbsp;Ravindra Sarode\",\"doi\":\"10.1016/j.rpth.2024.102422\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>To overcome deficiencies of the traditional von Willebrand factor (VWF) ristocetin cofactor activity assay (VWF:RCo), several automated assays for VWF platelet-binding activity have been developed. Information on the performance of these assays and their diagnostic utility remains limited.</p></div><div><h3>Objectives</h3><p>To validate the VWF:glycoprotein IbM assay INNOVANCE VWF Ac and compare it with an automated VWF:RCo assay as well as with an automated assay and a manual VWF:Ab assay and to generate reference ranges and analyze reproducibility of the VWF:glycoprotein IbM assay.</p></div><div><h3>Methods</h3><p>Clinical sites enrolled healthy subjects and patients representing the intended use population; VWF activity assays were performed, and results were analyzed. The performance of the INNOVANCE VWF Ac assay was also compared between the BCS XP System and the CS-2500 and CS-5100 analyzers.</p></div><div><h3>Results</h3><p>The INNOVANCE VWF Ac assay correlated well with the VWF:RCo assay and the automated HemosIL VWF:Ab assay, with Pearson coefficients of &gt;.9 and a predicted bias of ≤5.0 IU/dL at VWF levels of 30 IU/dL and ≤5.8 IU/dL at the levels of 50 IU/dL, but correlation and bias were not as good when compared with the REAADS manual VWF:Ab assay. Reference ranges observed for healthy subjects correlated well with previously published findings. Reproducibility of the INNOVANCE VWF Ac assay on the BCS XP System and the CS analyzers was excellent, as was correlation among devices.</p></div><div><h3>Conclusion</h3><p>The characteristics of the INNOVANCE VWF Ac assay regarding comparability with other VWF activity assays, reference ranges, and precision support the use of this assay for evaluation of patients with concern for von Willebrand disease.</p></div>\",\"PeriodicalId\":20893,\"journal\":{\"name\":\"Research and Practice in Thrombosis and Haemostasis\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2475037924001110/pdfft?md5=20f738306f5b1fbfde470ff1cf36ae5b&pid=1-s2.0-S2475037924001110-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Research and Practice in Thrombosis and Haemostasis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2475037924001110\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Research and Practice in Thrombosis and Haemostasis","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2475037924001110","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景为了克服传统的冯-威廉因子(VWF)里斯托西汀辅助因子活性测定法(VWF:RCo)的不足,人们开发了几种自动化的 VWF 血小板结合活性测定法。目标验证 VWF:glycoprotein IbM 检测法 INNOVANCE VWF Ac,并将其与自动 VWF:RCo 检测法以及自动检测法和手动 VWF:Ab 检测法进行比较,生成参考范围并分析 VWF:glycoprotein IbM 检测法的重现性。方法临床研究机构招募健康受试者和代表预期使用人群的患者;进行 VWF 活性检测并分析结果。结果INNOVANCE VWF Ac测定与VWF:RCo测定和自动HemosIL VWF:Ab测定有很好的相关性,皮尔逊系数为>;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;。9,当 VWF 水平为 30 IU/dL 时,预测偏差≤5.0 IU/dL,当 VWF 水平为 50 IU/dL 时,预测偏差≤5.8 IU/dL。在健康受试者身上观察到的参考范围与之前公布的结果有很好的相关性。结论INNOVANCE VWF Ac测定在与其他VWF活性测定的可比性、参考范围和精确度方面的特点支持将该测定用于评估Von Willebrand病患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of an automated von Willebrand factor glycoprotein IbM activity assay compared with 3 alternative von Willebrand factor activity assays

Background

To overcome deficiencies of the traditional von Willebrand factor (VWF) ristocetin cofactor activity assay (VWF:RCo), several automated assays for VWF platelet-binding activity have been developed. Information on the performance of these assays and their diagnostic utility remains limited.

Objectives

To validate the VWF:glycoprotein IbM assay INNOVANCE VWF Ac and compare it with an automated VWF:RCo assay as well as with an automated assay and a manual VWF:Ab assay and to generate reference ranges and analyze reproducibility of the VWF:glycoprotein IbM assay.

Methods

Clinical sites enrolled healthy subjects and patients representing the intended use population; VWF activity assays were performed, and results were analyzed. The performance of the INNOVANCE VWF Ac assay was also compared between the BCS XP System and the CS-2500 and CS-5100 analyzers.

Results

The INNOVANCE VWF Ac assay correlated well with the VWF:RCo assay and the automated HemosIL VWF:Ab assay, with Pearson coefficients of >.9 and a predicted bias of ≤5.0 IU/dL at VWF levels of 30 IU/dL and ≤5.8 IU/dL at the levels of 50 IU/dL, but correlation and bias were not as good when compared with the REAADS manual VWF:Ab assay. Reference ranges observed for healthy subjects correlated well with previously published findings. Reproducibility of the INNOVANCE VWF Ac assay on the BCS XP System and the CS analyzers was excellent, as was correlation among devices.

Conclusion

The characteristics of the INNOVANCE VWF Ac assay regarding comparability with other VWF activity assays, reference ranges, and precision support the use of this assay for evaluation of patients with concern for von Willebrand disease.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.60
自引率
13.00%
发文量
212
审稿时长
7 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信