Marta Revilla-León DDS, MSD, PhD, Jonathan M. Zeitler, John C. Kois DMD, MSD
{"title":"概述将上颌铸模转移到虚拟关节器的不同数字面弓方法。","authors":"Marta Revilla-León DDS, MSD, PhD, Jonathan M. Zeitler, John C. Kois DMD, MSD","doi":"10.1111/jerd.13264","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objectives</h3>\n \n <p>The purposes of this study were to classify the described digital facebow techniques for transferring the maxillary cast into the semi-adjustable virtual articulator based on the digital data acquisition technology used and to review the reported accuracy values of the different digital facebow methods described.</p>\n </section>\n \n <section>\n \n <h3> Overview</h3>\n \n <p>Digital data acquisition technologies, including digital photographs, facial scanners, cone beam computed tomography (CBCT) imaging, and jaw tracking systems, can be used to transfer the maxillary cast into the virtual articulator. The reported techniques are reviewed, as well as the reported accuracy values of the different digital facebow methods.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>Digital photographs can be used to transfer the maxillary cast into the virtual articulator using the true horizontal reference plane, but limited studies have assessed the accuracy of this method. Facial scanning and CBCT techniques can be used to transfer the maxillary cast into the virtual articulator, in which the most frequently selected references planes are the Frankfort horizontal, axis orbital, and true horizontal planes. Studies analyzing the accuracy of the maxillary cast transfer by using facial scanning and CBCT techniques are restricted. Lastly, optical jaw trackers can be selected for transferring the maxillary cast into the virtual articulator by using the axis orbital or true horizontal planes, yet the accuracy of these systems is unknown.</p>\n </section>\n \n <section>\n \n <h3> Clinical Implications</h3>\n \n <p>Digital data acquisition technologies, including digital photographs, facial scanning methods, CBCTs, and optical jaw tracking systems, can be used to transfer the maxillary cast into the virtual articulator. Studies are needed to assess the accuracy of these digital data acquisition technologies for transferring the maxillary cast into the virtual articulator.</p>\n </section>\n </div>","PeriodicalId":15988,"journal":{"name":"Journal of Esthetic and Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An overview of the different digital facebow methods for transferring the maxillary cast into the virtual articulator\",\"authors\":\"Marta Revilla-León DDS, MSD, PhD, Jonathan M. Zeitler, John C. Kois DMD, MSD\",\"doi\":\"10.1111/jerd.13264\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Objectives</h3>\\n \\n <p>The purposes of this study were to classify the described digital facebow techniques for transferring the maxillary cast into the semi-adjustable virtual articulator based on the digital data acquisition technology used and to review the reported accuracy values of the different digital facebow methods described.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Overview</h3>\\n \\n <p>Digital data acquisition technologies, including digital photographs, facial scanners, cone beam computed tomography (CBCT) imaging, and jaw tracking systems, can be used to transfer the maxillary cast into the virtual articulator. The reported techniques are reviewed, as well as the reported accuracy values of the different digital facebow methods.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>Digital photographs can be used to transfer the maxillary cast into the virtual articulator using the true horizontal reference plane, but limited studies have assessed the accuracy of this method. Facial scanning and CBCT techniques can be used to transfer the maxillary cast into the virtual articulator, in which the most frequently selected references planes are the Frankfort horizontal, axis orbital, and true horizontal planes. Studies analyzing the accuracy of the maxillary cast transfer by using facial scanning and CBCT techniques are restricted. Lastly, optical jaw trackers can be selected for transferring the maxillary cast into the virtual articulator by using the axis orbital or true horizontal planes, yet the accuracy of these systems is unknown.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Clinical Implications</h3>\\n \\n <p>Digital data acquisition technologies, including digital photographs, facial scanning methods, CBCTs, and optical jaw tracking systems, can be used to transfer the maxillary cast into the virtual articulator. Studies are needed to assess the accuracy of these digital data acquisition technologies for transferring the maxillary cast into the virtual articulator.</p>\\n </section>\\n </div>\",\"PeriodicalId\":15988,\"journal\":{\"name\":\"Journal of Esthetic and Restorative Dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Esthetic and Restorative Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/jerd.13264\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Esthetic and Restorative Dentistry","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jerd.13264","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
An overview of the different digital facebow methods for transferring the maxillary cast into the virtual articulator
Objectives
The purposes of this study were to classify the described digital facebow techniques for transferring the maxillary cast into the semi-adjustable virtual articulator based on the digital data acquisition technology used and to review the reported accuracy values of the different digital facebow methods described.
Overview
Digital data acquisition technologies, including digital photographs, facial scanners, cone beam computed tomography (CBCT) imaging, and jaw tracking systems, can be used to transfer the maxillary cast into the virtual articulator. The reported techniques are reviewed, as well as the reported accuracy values of the different digital facebow methods.
Conclusions
Digital photographs can be used to transfer the maxillary cast into the virtual articulator using the true horizontal reference plane, but limited studies have assessed the accuracy of this method. Facial scanning and CBCT techniques can be used to transfer the maxillary cast into the virtual articulator, in which the most frequently selected references planes are the Frankfort horizontal, axis orbital, and true horizontal planes. Studies analyzing the accuracy of the maxillary cast transfer by using facial scanning and CBCT techniques are restricted. Lastly, optical jaw trackers can be selected for transferring the maxillary cast into the virtual articulator by using the axis orbital or true horizontal planes, yet the accuracy of these systems is unknown.
Clinical Implications
Digital data acquisition technologies, including digital photographs, facial scanning methods, CBCTs, and optical jaw tracking systems, can be used to transfer the maxillary cast into the virtual articulator. Studies are needed to assess the accuracy of these digital data acquisition technologies for transferring the maxillary cast into the virtual articulator.
期刊介绍:
The Journal of Esthetic and Restorative Dentistry (JERD) is the longest standing peer-reviewed journal devoted solely to advancing the knowledge and practice of esthetic dentistry. Its goal is to provide the very latest evidence-based information in the realm of contemporary interdisciplinary esthetic dentistry through high quality clinical papers, sound research reports and educational features.
The range of topics covered in the journal includes:
- Interdisciplinary esthetic concepts
- Implants
- Conservative adhesive restorations
- Tooth Whitening
- Prosthodontic materials and techniques
- Dental materials
- Orthodontic, periodontal and endodontic esthetics
- Esthetics related research
- Innovations in esthetics