三维眼前节光学相干断层扫描在检测闭角方面的诊断能力。

IF 2 4区 医学 Q2 OPHTHALMOLOGY
Journal of Glaucoma Pub Date : 2024-10-01 Epub Date: 2024-05-24 DOI:10.1097/IJG.0000000000002442
Sunee Chansangpetch, Phichayut Phinyo, Jayanton Patumanond, Janejit Choovuthayakorn, Shan C Lin
{"title":"三维眼前节光学相干断层扫描在检测闭角方面的诊断能力。","authors":"Sunee Chansangpetch, Phichayut Phinyo, Jayanton Patumanond, Janejit Choovuthayakorn, Shan C Lin","doi":"10.1097/IJG.0000000000002442","DOIUrl":null,"url":null,"abstract":"<p><strong>Prcis: </strong>Three-dimensional (3D) angle parameters and cutoff values for detecting angle closure were proposed. The 3D parameters demonstrated excellent diagnostic performance. Certain horizontal two-dimensional (2D) parameters [ie, trabecular iris space area (TISA)-750, angle opening distance (AOD)-750, and AOD-500] can attain similar performance to their high-performing 3D counterparts.</p><p><strong>Objective: </strong>To investigate the diagnostic performance of single horizontal 2D versus 3D angle parameters from swept-source anterior segment optical coherence tomography (CASIA2) in detecting angle closure.</p><p><strong>Materials and methods: </strong>The cross-sectional study included 118 phakic patients (59 open angles, 59 closed angles). AOD, angle recess area (ARA), and TISA at 250, 500, and 750 μm from scleral spur were measured in 360-degree radial-scan images. The 3D information of each measurement was analyzed in 2 patterns: (1) average 3D parameter-the averaged value from 360-degree angle values and (2) estimate 3D parameter-the estimation of surface area of circumferential angle inlet (using AOD) or circumferential angle volume (using ARA and TISA). The areas under the receiver operating characteristic curve [areas under the curve (AUCs)] of eighteen 3D parameters were compared with 2D horizontal parameters.</p><p><strong>Results: </strong>Among 3D parameters, AOD-500 estimate 3D gave the highest AUC (AUC: 0.950, cutoff: 6.09 mm 2 ), followed by AOD-750 estimate 3D (AUC: 0.948, cutoff: 8.26 mm 2 ). 3D parameters significantly increased the AUC of ARA-250 and TISA-250 (all P < 0.02) compared with the 2D parameters. No significant improvement in AUC was demonstrated for AOD-250 and all parameters at 500 and 750 μm. No significant difference in AUC was found among the 6 maximum AUC parameters, which were AOD-750 horizontal 2D, AOD-500 estimate 3D, TISA-750 horizontal 2D, AOD-500 horizontal 2D, AOD-750 estimate 3D, and TISA-750 average 3D.</p><p><strong>Conclusions: </strong>The 3D-angle parameters had high performance in detecting angle closure. However, comparing a horizontal measurement to 3D parameters, the AUC improvement was mostly insignificant.</p>","PeriodicalId":15938,"journal":{"name":"Journal of Glaucoma","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Diagnostic Abilities of Three-Dimensional Anterior Segment Optical Coherence Tomography in Detecting Angle Closure.\",\"authors\":\"Sunee Chansangpetch, Phichayut Phinyo, Jayanton Patumanond, Janejit Choovuthayakorn, Shan C Lin\",\"doi\":\"10.1097/IJG.0000000000002442\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Prcis: </strong>Three-dimensional (3D) angle parameters and cutoff values for detecting angle closure were proposed. The 3D parameters demonstrated excellent diagnostic performance. Certain horizontal two-dimensional (2D) parameters [ie, trabecular iris space area (TISA)-750, angle opening distance (AOD)-750, and AOD-500] can attain similar performance to their high-performing 3D counterparts.</p><p><strong>Objective: </strong>To investigate the diagnostic performance of single horizontal 2D versus 3D angle parameters from swept-source anterior segment optical coherence tomography (CASIA2) in detecting angle closure.</p><p><strong>Materials and methods: </strong>The cross-sectional study included 118 phakic patients (59 open angles, 59 closed angles). AOD, angle recess area (ARA), and TISA at 250, 500, and 750 μm from scleral spur were measured in 360-degree radial-scan images. The 3D information of each measurement was analyzed in 2 patterns: (1) average 3D parameter-the averaged value from 360-degree angle values and (2) estimate 3D parameter-the estimation of surface area of circumferential angle inlet (using AOD) or circumferential angle volume (using ARA and TISA). The areas under the receiver operating characteristic curve [areas under the curve (AUCs)] of eighteen 3D parameters were compared with 2D horizontal parameters.</p><p><strong>Results: </strong>Among 3D parameters, AOD-500 estimate 3D gave the highest AUC (AUC: 0.950, cutoff: 6.09 mm 2 ), followed by AOD-750 estimate 3D (AUC: 0.948, cutoff: 8.26 mm 2 ). 3D parameters significantly increased the AUC of ARA-250 and TISA-250 (all P < 0.02) compared with the 2D parameters. No significant improvement in AUC was demonstrated for AOD-250 and all parameters at 500 and 750 μm. No significant difference in AUC was found among the 6 maximum AUC parameters, which were AOD-750 horizontal 2D, AOD-500 estimate 3D, TISA-750 horizontal 2D, AOD-500 horizontal 2D, AOD-750 estimate 3D, and TISA-750 average 3D.</p><p><strong>Conclusions: </strong>The 3D-angle parameters had high performance in detecting angle closure. However, comparing a horizontal measurement to 3D parameters, the AUC improvement was mostly insignificant.</p>\",\"PeriodicalId\":15938,\"journal\":{\"name\":\"Journal of Glaucoma\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Glaucoma\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/IJG.0000000000002442\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/24 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Glaucoma","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/IJG.0000000000002442","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/24 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

Prcis:提出了用于检测闭角的三维角度参数和临界值。三维参数表现出卓越的诊断性能。目的:研究扫源前段光学相干断层成像(CASIA2)中单一水平二维(2D)与三维(3D)角度参数在检测闭角方面的诊断性能:横断面研究包括 118 名咽鼓管受试者(59 名开角型,59 名闭角型)。在 360° 径向扫描图像中测量了距巩膜骨刺 250、500 和 750 μm 处的开角距离 (AOD)、角凹面积 (ARA)、小梁-虹膜间隙面积 (TISA)。每个测量值的三维信息按两种模式进行分析:(1) 平均三维参数 - 360 度角值的平均值;(2) 估计三维参数 - 估计圆周角入口表面积(使用 AOD)或圆周角体积(使用 ARA 和 TISA)。18 个三维参数的接收器工作曲线下面积(AUC)与二维水平参数进行了比较:在三维参数中,AOD-500 估计三维参数的 AUC 最高(AUC 0.950,临界值为 6.09 mm2),其次是 AOD-750 估计三维参数(AUC 0.948,临界值为 8.26 mm2)。三维参数明显提高了 ARA-250 和 TISA-250 的 AUC(所有 PConclusions):三维角度参数在检测闭角方面具有很高的性能。然而,将水平测量与三维参数相比,AUC 的提高大多不明显。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Diagnostic Abilities of Three-Dimensional Anterior Segment Optical Coherence Tomography in Detecting Angle Closure.

Prcis: Three-dimensional (3D) angle parameters and cutoff values for detecting angle closure were proposed. The 3D parameters demonstrated excellent diagnostic performance. Certain horizontal two-dimensional (2D) parameters [ie, trabecular iris space area (TISA)-750, angle opening distance (AOD)-750, and AOD-500] can attain similar performance to their high-performing 3D counterparts.

Objective: To investigate the diagnostic performance of single horizontal 2D versus 3D angle parameters from swept-source anterior segment optical coherence tomography (CASIA2) in detecting angle closure.

Materials and methods: The cross-sectional study included 118 phakic patients (59 open angles, 59 closed angles). AOD, angle recess area (ARA), and TISA at 250, 500, and 750 μm from scleral spur were measured in 360-degree radial-scan images. The 3D information of each measurement was analyzed in 2 patterns: (1) average 3D parameter-the averaged value from 360-degree angle values and (2) estimate 3D parameter-the estimation of surface area of circumferential angle inlet (using AOD) or circumferential angle volume (using ARA and TISA). The areas under the receiver operating characteristic curve [areas under the curve (AUCs)] of eighteen 3D parameters were compared with 2D horizontal parameters.

Results: Among 3D parameters, AOD-500 estimate 3D gave the highest AUC (AUC: 0.950, cutoff: 6.09 mm 2 ), followed by AOD-750 estimate 3D (AUC: 0.948, cutoff: 8.26 mm 2 ). 3D parameters significantly increased the AUC of ARA-250 and TISA-250 (all P < 0.02) compared with the 2D parameters. No significant improvement in AUC was demonstrated for AOD-250 and all parameters at 500 and 750 μm. No significant difference in AUC was found among the 6 maximum AUC parameters, which were AOD-750 horizontal 2D, AOD-500 estimate 3D, TISA-750 horizontal 2D, AOD-500 horizontal 2D, AOD-750 estimate 3D, and TISA-750 average 3D.

Conclusions: The 3D-angle parameters had high performance in detecting angle closure. However, comparing a horizontal measurement to 3D parameters, the AUC improvement was mostly insignificant.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Glaucoma
Journal of Glaucoma 医学-眼科学
CiteScore
4.20
自引率
10.00%
发文量
330
审稿时长
4-8 weeks
期刊介绍: The Journal of Glaucoma is a peer reviewed journal addressing the spectrum of issues affecting definition, diagnosis, and management of glaucoma and providing a forum for lively and stimulating discussion of clinical, scientific, and socioeconomic factors affecting care of glaucoma patients.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信