Cynthia Bir, Adam Menkara, Rodrigo Villalta, Michele Bodo, Sebastien Roth, Don Sherman
{"title":"用于评估伤口痕迹的明胶替代物比较。","authors":"Cynthia Bir, Adam Menkara, Rodrigo Villalta, Michele Bodo, Sebastien Roth, Don Sherman","doi":"10.1007/s00414-024-03221-3","DOIUrl":null,"url":null,"abstract":"<p><p>The use of ordnance gelatine has been widespread in the field of ballistics as a simulant for soft tissue when assessing ballistic threats. However, the traditional method of preparing ordnance gelatine is time-consuming and requires precision to ensure that the final mold meets the required specifications. Furthermore, temperature control is necessary post-production, and there are limitations on its usage duration. To address these issues, manufacturers have developed pre-mixed, gelatine-like products that are stable at room temperature and require less preparation time. Nonetheless, it is uncertain whether these new products can perform in the same manner as the gold standard of ordnance gelatine. This study used five types of blocks, including ordnance gelatine (10% and 20%), Clear Ballistics (10% and 20%) and Perma-Gel (10%) and subjected them to 9 mm, 0.380 Auto fired from a universal receiver and a 5.56 × 45 mm ammunition fired by a certified firearms instructor. Delta-V and total energy dissipation were measured after each test using data collected from ballistic chronographs placed in front of and behind each block. High-speed video was recorded, and a cut-down analysis conducted. The findings revealed variations in energy dissipation and fissure formation within the block, with greater energy based on fissure formation observed in the ordnance gelatine. Additionally, the high-speed video showed the occurrence of secondary combustions occurring in the premixed gelatines.</p>","PeriodicalId":14071,"journal":{"name":"International Journal of Legal Medicine","volume":null,"pages":null},"PeriodicalIF":2.2000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A comparison of gelatine surrogates for wound track assessment.\",\"authors\":\"Cynthia Bir, Adam Menkara, Rodrigo Villalta, Michele Bodo, Sebastien Roth, Don Sherman\",\"doi\":\"10.1007/s00414-024-03221-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The use of ordnance gelatine has been widespread in the field of ballistics as a simulant for soft tissue when assessing ballistic threats. However, the traditional method of preparing ordnance gelatine is time-consuming and requires precision to ensure that the final mold meets the required specifications. Furthermore, temperature control is necessary post-production, and there are limitations on its usage duration. To address these issues, manufacturers have developed pre-mixed, gelatine-like products that are stable at room temperature and require less preparation time. Nonetheless, it is uncertain whether these new products can perform in the same manner as the gold standard of ordnance gelatine. This study used five types of blocks, including ordnance gelatine (10% and 20%), Clear Ballistics (10% and 20%) and Perma-Gel (10%) and subjected them to 9 mm, 0.380 Auto fired from a universal receiver and a 5.56 × 45 mm ammunition fired by a certified firearms instructor. Delta-V and total energy dissipation were measured after each test using data collected from ballistic chronographs placed in front of and behind each block. High-speed video was recorded, and a cut-down analysis conducted. The findings revealed variations in energy dissipation and fissure formation within the block, with greater energy based on fissure formation observed in the ordnance gelatine. Additionally, the high-speed video showed the occurrence of secondary combustions occurring in the premixed gelatines.</p>\",\"PeriodicalId\":14071,\"journal\":{\"name\":\"International Journal of Legal Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Legal Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00414-024-03221-3\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICINE, LEGAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Legal Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00414-024-03221-3","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/22 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"MEDICINE, LEGAL","Score":null,"Total":0}
A comparison of gelatine surrogates for wound track assessment.
The use of ordnance gelatine has been widespread in the field of ballistics as a simulant for soft tissue when assessing ballistic threats. However, the traditional method of preparing ordnance gelatine is time-consuming and requires precision to ensure that the final mold meets the required specifications. Furthermore, temperature control is necessary post-production, and there are limitations on its usage duration. To address these issues, manufacturers have developed pre-mixed, gelatine-like products that are stable at room temperature and require less preparation time. Nonetheless, it is uncertain whether these new products can perform in the same manner as the gold standard of ordnance gelatine. This study used five types of blocks, including ordnance gelatine (10% and 20%), Clear Ballistics (10% and 20%) and Perma-Gel (10%) and subjected them to 9 mm, 0.380 Auto fired from a universal receiver and a 5.56 × 45 mm ammunition fired by a certified firearms instructor. Delta-V and total energy dissipation were measured after each test using data collected from ballistic chronographs placed in front of and behind each block. High-speed video was recorded, and a cut-down analysis conducted. The findings revealed variations in energy dissipation and fissure formation within the block, with greater energy based on fissure formation observed in the ordnance gelatine. Additionally, the high-speed video showed the occurrence of secondary combustions occurring in the premixed gelatines.
期刊介绍:
The International Journal of Legal Medicine aims to improve the scientific resources used in the elucidation of crime and related forensic applications at a high level of evidential proof. The journal offers review articles tracing development in specific areas, with up-to-date analysis; original articles discussing significant recent research results; case reports describing interesting and exceptional examples; population data; letters to the editors; and technical notes, which appear in a section originally created for rapid publication of data in the dynamic field of DNA analysis.