{"title":"微流体技术通过单细胞分析鉴定毛竹和楠竹的叶片原生质亚群。","authors":"Yameng Liu, Mingxu Wang, Xiaohu Wang","doi":"10.1002/jssc.202400120","DOIUrl":null,"url":null,"abstract":"<p>Current techniques identifying herbal medicine species require marker labeling or lack systematical accuracy (expert authentication). There is an emerging interest in developing an accurate and label-free tool for herbal medicine authentication. Here, a high-resolution microfluidic-based method is developed for identifying herbal species by protoplast subpopulations. Moso bamboo and henon bamboo are used as a model to be differentiated based on protoplast. Their biophysical properties factors are characterized to be 7.09 (± 0.39) × 10<sup>8</sup> V/m<sup>2</sup> and 6.54 (± 0.26) × 10<sup>8 </sup>V/m<sup>2</sup>, respectively. Their biophysical distributions could be distinguished by the Cramér–von Mises criterion with a 94.60% confidence level. The subpopulations of each were compared with conventional flow cytometry indicating the existence of subpopulations and the differences between the two species. The subsets divided by a biophysical factor of 8.05(± 0.51) × 10<sup>8</sup> V/m<sup>2</sup> suggest good consistency with flow cytometry. The work demonstrated the possibility of microfluidics manipulation on protoplast for medication safety use taking advantage of dielectrophoresis. The device is promising in developing a reliable and accurate way of identifying herbal species with difficulties in authentication.</p>","PeriodicalId":17098,"journal":{"name":"Journal of separation science","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2024-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Microfluidics identify moso bamboo and henon bamboo by leaf protoplast subpopulations with single-cell analysis\",\"authors\":\"Yameng Liu, Mingxu Wang, Xiaohu Wang\",\"doi\":\"10.1002/jssc.202400120\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Current techniques identifying herbal medicine species require marker labeling or lack systematical accuracy (expert authentication). There is an emerging interest in developing an accurate and label-free tool for herbal medicine authentication. Here, a high-resolution microfluidic-based method is developed for identifying herbal species by protoplast subpopulations. Moso bamboo and henon bamboo are used as a model to be differentiated based on protoplast. Their biophysical properties factors are characterized to be 7.09 (± 0.39) × 10<sup>8</sup> V/m<sup>2</sup> and 6.54 (± 0.26) × 10<sup>8 </sup>V/m<sup>2</sup>, respectively. Their biophysical distributions could be distinguished by the Cramér–von Mises criterion with a 94.60% confidence level. The subpopulations of each were compared with conventional flow cytometry indicating the existence of subpopulations and the differences between the two species. The subsets divided by a biophysical factor of 8.05(± 0.51) × 10<sup>8</sup> V/m<sup>2</sup> suggest good consistency with flow cytometry. The work demonstrated the possibility of microfluidics manipulation on protoplast for medication safety use taking advantage of dielectrophoresis. The device is promising in developing a reliable and accurate way of identifying herbal species with difficulties in authentication.</p>\",\"PeriodicalId\":17098,\"journal\":{\"name\":\"Journal of separation science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-05-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of separation science\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/jssc.202400120\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of separation science","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jssc.202400120","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Microfluidics identify moso bamboo and henon bamboo by leaf protoplast subpopulations with single-cell analysis
Current techniques identifying herbal medicine species require marker labeling or lack systematical accuracy (expert authentication). There is an emerging interest in developing an accurate and label-free tool for herbal medicine authentication. Here, a high-resolution microfluidic-based method is developed for identifying herbal species by protoplast subpopulations. Moso bamboo and henon bamboo are used as a model to be differentiated based on protoplast. Their biophysical properties factors are characterized to be 7.09 (± 0.39) × 108 V/m2 and 6.54 (± 0.26) × 108 V/m2, respectively. Their biophysical distributions could be distinguished by the Cramér–von Mises criterion with a 94.60% confidence level. The subpopulations of each were compared with conventional flow cytometry indicating the existence of subpopulations and the differences between the two species. The subsets divided by a biophysical factor of 8.05(± 0.51) × 108 V/m2 suggest good consistency with flow cytometry. The work demonstrated the possibility of microfluidics manipulation on protoplast for medication safety use taking advantage of dielectrophoresis. The device is promising in developing a reliable and accurate way of identifying herbal species with difficulties in authentication.
期刊介绍:
The Journal of Separation Science (JSS) is the most comprehensive source in separation science, since it covers all areas of chromatographic and electrophoretic separation methods in theory and practice, both in the analytical and in the preparative mode, solid phase extraction, sample preparation, and related techniques. Manuscripts on methodological or instrumental developments, including detection aspects, in particular mass spectrometry, as well as on innovative applications will also be published. Manuscripts on hyphenation, automation, and miniaturization are particularly welcome. Pre- and post-separation facets of a total analysis may be covered as well as the underlying logic of the development or application of a method.