Peng Zhang , Yi Tao , Chunhao Yang , Wuning Ma , Zhendong Zhang
{"title":"通过 CFD 方法模拟高压气动先导式开关阀的瞬态特性并进行流场分析","authors":"Peng Zhang , Yi Tao , Chunhao Yang , Wuning Ma , Zhendong Zhang","doi":"10.1016/j.flowmeasinst.2024.102620","DOIUrl":null,"url":null,"abstract":"<div><p>To improve the internal ballistic performance of compressed-air ejection devices and achieve continuous launching, it is essential to investigate the dynamic characteristics and transient flow field during the opening and closing of the high-pressure pneumatic pilot-driven on/off valve (HPPV) within the device. A transient fluid-simulation model of the HPPV is established in Fluent using a sliding mesh and 6 Degree of Freedom (DOF) dynamic mesh technology, and experiments are conducted to evaluate the solution accuracy of the model. Meanwhile, the influence of real-gas thermal and wall heat-transfer effects on the simulation model are investigated, and the transient flow field of the HPPV is analyzed during its opening and closing under a high-pressure initial gas source. The maximum tolerance between the results of the HPPV transient fluid-simulation model based on the CFD method and experimental data is 5.87 % under different initial pressures. Both the wall heat transfer and real gas thermal effects impact the accuracy of the transient fluid model for HPPV. Considering these factors leads to a 2–3% enhancement in the solving accuracy of the model. The Joule–Thomson effect inside the pilot-valve and control gas chambers is evident. The pilot-valve chamber is susceptible to leakage and sealing failure owing to significant pressure and temperature differences between the two sides of the gas. The temperatures of the chamber for the opening and closing valves are low during the exhaust process, which enables ice to be formed easily inside the chamber.</p></div>","PeriodicalId":50440,"journal":{"name":"Flow Measurement and Instrumentation","volume":"97 ","pages":"Article 102620"},"PeriodicalIF":2.3000,"publicationDate":"2024-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Transient characteristics simulation and flow-field analysis of high-pressure pneumatic pilot-driven on/off valve via CFD method\",\"authors\":\"Peng Zhang , Yi Tao , Chunhao Yang , Wuning Ma , Zhendong Zhang\",\"doi\":\"10.1016/j.flowmeasinst.2024.102620\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>To improve the internal ballistic performance of compressed-air ejection devices and achieve continuous launching, it is essential to investigate the dynamic characteristics and transient flow field during the opening and closing of the high-pressure pneumatic pilot-driven on/off valve (HPPV) within the device. A transient fluid-simulation model of the HPPV is established in Fluent using a sliding mesh and 6 Degree of Freedom (DOF) dynamic mesh technology, and experiments are conducted to evaluate the solution accuracy of the model. Meanwhile, the influence of real-gas thermal and wall heat-transfer effects on the simulation model are investigated, and the transient flow field of the HPPV is analyzed during its opening and closing under a high-pressure initial gas source. The maximum tolerance between the results of the HPPV transient fluid-simulation model based on the CFD method and experimental data is 5.87 % under different initial pressures. Both the wall heat transfer and real gas thermal effects impact the accuracy of the transient fluid model for HPPV. Considering these factors leads to a 2–3% enhancement in the solving accuracy of the model. The Joule–Thomson effect inside the pilot-valve and control gas chambers is evident. The pilot-valve chamber is susceptible to leakage and sealing failure owing to significant pressure and temperature differences between the two sides of the gas. The temperatures of the chamber for the opening and closing valves are low during the exhaust process, which enables ice to be formed easily inside the chamber.</p></div>\",\"PeriodicalId\":50440,\"journal\":{\"name\":\"Flow Measurement and Instrumentation\",\"volume\":\"97 \",\"pages\":\"Article 102620\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Flow Measurement and Instrumentation\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0955598624001006\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Flow Measurement and Instrumentation","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0955598624001006","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
Transient characteristics simulation and flow-field analysis of high-pressure pneumatic pilot-driven on/off valve via CFD method
To improve the internal ballistic performance of compressed-air ejection devices and achieve continuous launching, it is essential to investigate the dynamic characteristics and transient flow field during the opening and closing of the high-pressure pneumatic pilot-driven on/off valve (HPPV) within the device. A transient fluid-simulation model of the HPPV is established in Fluent using a sliding mesh and 6 Degree of Freedom (DOF) dynamic mesh technology, and experiments are conducted to evaluate the solution accuracy of the model. Meanwhile, the influence of real-gas thermal and wall heat-transfer effects on the simulation model are investigated, and the transient flow field of the HPPV is analyzed during its opening and closing under a high-pressure initial gas source. The maximum tolerance between the results of the HPPV transient fluid-simulation model based on the CFD method and experimental data is 5.87 % under different initial pressures. Both the wall heat transfer and real gas thermal effects impact the accuracy of the transient fluid model for HPPV. Considering these factors leads to a 2–3% enhancement in the solving accuracy of the model. The Joule–Thomson effect inside the pilot-valve and control gas chambers is evident. The pilot-valve chamber is susceptible to leakage and sealing failure owing to significant pressure and temperature differences between the two sides of the gas. The temperatures of the chamber for the opening and closing valves are low during the exhaust process, which enables ice to be formed easily inside the chamber.
期刊介绍:
Flow Measurement and Instrumentation is dedicated to disseminating the latest research results on all aspects of flow measurement, in both closed conduits and open channels. The design of flow measurement systems involves a wide variety of multidisciplinary activities including modelling the flow sensor, the fluid flow and the sensor/fluid interactions through the use of computation techniques; the development of advanced transducer systems and their associated signal processing and the laboratory and field assessment of the overall system under ideal and disturbed conditions.
FMI is the essential forum for critical information exchange, and contributions are particularly encouraged in the following areas of interest:
Modelling: the application of mathematical and computational modelling to the interaction of fluid dynamics with flowmeters, including flowmeter behaviour, improved flowmeter design and installation problems. Application of CAD/CAE techniques to flowmeter modelling are eligible.
Design and development: the detailed design of the flowmeter head and/or signal processing aspects of novel flowmeters. Emphasis is given to papers identifying new sensor configurations, multisensor flow measurement systems, non-intrusive flow metering techniques and the application of microelectronic techniques in smart or intelligent systems.
Calibration techniques: including descriptions of new or existing calibration facilities and techniques, calibration data from different flowmeter types, and calibration intercomparison data from different laboratories.
Installation effect data: dealing with the effects of non-ideal flow conditions on flowmeters. Papers combining a theoretical understanding of flowmeter behaviour with experimental work are particularly welcome.