为一名患有严重二尖瓣返流的狼疮患者进行肾移植手术的连续脊髓麻醉:病例报告

IF 0.9 Q3 ANESTHESIOLOGY
A.A. Pires , M.J. Correia , J. Sousa
{"title":"为一名患有严重二尖瓣返流的狼疮患者进行肾移植手术的连续脊髓麻醉:病例报告","authors":"A.A. Pires ,&nbsp;M.J. Correia ,&nbsp;J. Sousa","doi":"10.1016/j.redar.2024.01.009","DOIUrl":null,"url":null,"abstract":"<div><div>Anaesthesia for kidney transplant in a patient with severe mitral regurgitation is a real challenge given the need for judicious haemodynamic management to avoid pulmonary oedema and maximise reperfusion of the transplanted organ. This is the first experience described in the literature of continuous spinal anaesthesia in a patient with chronic severe mitral regurgitation undergoing cadaver donor kidney transplant. Transthoracic echocardiography monitoring was used during the procedure to avoid aggravating the patient's mitral regurgitation. Intraoperatively, 17.5<!--> <!-->ml/kg of crystalloids were administered and no vasopressors were required. Continuous spinal anaesthesia preserved haemodynamics and graft perfusion during the procedure.</div></div>","PeriodicalId":46479,"journal":{"name":"Revista Espanola de Anestesiologia y Reanimacion","volume":"72 1","pages":"Article 101617"},"PeriodicalIF":0.9000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Anestesia espinal continua para trasplante renal en una paciente de lupus con regurgitación mitral grave: informe de un caso\",\"authors\":\"A.A. Pires ,&nbsp;M.J. Correia ,&nbsp;J. Sousa\",\"doi\":\"10.1016/j.redar.2024.01.009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Anaesthesia for kidney transplant in a patient with severe mitral regurgitation is a real challenge given the need for judicious haemodynamic management to avoid pulmonary oedema and maximise reperfusion of the transplanted organ. This is the first experience described in the literature of continuous spinal anaesthesia in a patient with chronic severe mitral regurgitation undergoing cadaver donor kidney transplant. Transthoracic echocardiography monitoring was used during the procedure to avoid aggravating the patient's mitral regurgitation. Intraoperatively, 17.5<!--> <!-->ml/kg of crystalloids were administered and no vasopressors were required. Continuous spinal anaesthesia preserved haemodynamics and graft perfusion during the procedure.</div></div>\",\"PeriodicalId\":46479,\"journal\":{\"name\":\"Revista Espanola de Anestesiologia y Reanimacion\",\"volume\":\"72 1\",\"pages\":\"Article 101617\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista Espanola de Anestesiologia y Reanimacion\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0034935624000665\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Espanola de Anestesiologia y Reanimacion","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0034935624000665","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

严重二尖瓣返流患者的肾移植麻醉是一个真正的挑战,因为需要明智的血流动力学管理,以避免肺水肿和最大限度地提高移植器官的再灌注。这是文献中首次描述的慢性严重二尖瓣反流患者接受尸体供体肾移植时持续脊髓麻醉的经验。在手术过程中使用经胸超声心动图监测,以避免加重患者的二尖瓣反流。术中给予17.5 ml/kg晶体,不需要血管加压药。在手术过程中,持续的脊髓麻醉保持了血流动力学和移植物灌注。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Anestesia espinal continua para trasplante renal en una paciente de lupus con regurgitación mitral grave: informe de un caso
Anaesthesia for kidney transplant in a patient with severe mitral regurgitation is a real challenge given the need for judicious haemodynamic management to avoid pulmonary oedema and maximise reperfusion of the transplanted organ. This is the first experience described in the literature of continuous spinal anaesthesia in a patient with chronic severe mitral regurgitation undergoing cadaver donor kidney transplant. Transthoracic echocardiography monitoring was used during the procedure to avoid aggravating the patient's mitral regurgitation. Intraoperatively, 17.5 ml/kg of crystalloids were administered and no vasopressors were required. Continuous spinal anaesthesia preserved haemodynamics and graft perfusion during the procedure.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.80
自引率
15.40%
发文量
113
审稿时长
82 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信