Aatish Jeebodh , Buick Davison , Martyn S. McLaggan , Ian Burgess , Danny Hopkin , Shan-Shan Huang
{"title":"火灾中连续弹性侧向约束对钢木混合结构梁和梁-柱的影响","authors":"Aatish Jeebodh , Buick Davison , Martyn S. McLaggan , Ian Burgess , Danny Hopkin , Shan-Shan Huang","doi":"10.1016/j.firesaf.2024.104172","DOIUrl":null,"url":null,"abstract":"<div><p>With the climate crisis and pursuit of efforts to reduce embodied carbon impacts in the built environment, steel-timber hybrid structures have emerged as a sustainable form of framed construction which offer numerous benefits over the widely used and well-established steel-concrete hybrid structures. However, there are major concerns about the structural fire performance of such systems among various stakeholders in the construction industry, particularly for the design implications in terms of the lateral-torsional buckling behaviour and the degree of lateral restraint mobilised in the steel-to-timber connections. The screws that connect cross-laminated timber slabs to steel beams may provide a certain degree of restraining action in fire. However, further investigations are required to quantify the slip characteristics of such connections. In this study, it was found from existing literature that at the fire limit state, the continuous elastic lateral stiffness available to restrain the beam varies between approximately 500 kN/m/m and 2000 kN/m/m. Relying entirely on the screws and using this practical range of stiffness, a parametric study using Eurocode 3 design buckling resistance equations on 9 m simply supported span steel beams and beam-columns with span-to-depth ratios of about 10, 15, 20 and 25 was performed. The results indicate that designing such members as fully restrained in fire conditions may lead to unrealistic assumptions and unsafe structures.</p></div>","PeriodicalId":50445,"journal":{"name":"Fire Safety Journal","volume":"146 ","pages":"Article 104172"},"PeriodicalIF":3.4000,"publicationDate":"2024-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0379711224000857/pdfft?md5=2d0c2fe506d6f9cf48329634efd0e539&pid=1-s2.0-S0379711224000857-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Influence of continuous elastic lateral restraints on beams and beam-columns of steel-timber hybrid structures in fire\",\"authors\":\"Aatish Jeebodh , Buick Davison , Martyn S. McLaggan , Ian Burgess , Danny Hopkin , Shan-Shan Huang\",\"doi\":\"10.1016/j.firesaf.2024.104172\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>With the climate crisis and pursuit of efforts to reduce embodied carbon impacts in the built environment, steel-timber hybrid structures have emerged as a sustainable form of framed construction which offer numerous benefits over the widely used and well-established steel-concrete hybrid structures. However, there are major concerns about the structural fire performance of such systems among various stakeholders in the construction industry, particularly for the design implications in terms of the lateral-torsional buckling behaviour and the degree of lateral restraint mobilised in the steel-to-timber connections. The screws that connect cross-laminated timber slabs to steel beams may provide a certain degree of restraining action in fire. However, further investigations are required to quantify the slip characteristics of such connections. In this study, it was found from existing literature that at the fire limit state, the continuous elastic lateral stiffness available to restrain the beam varies between approximately 500 kN/m/m and 2000 kN/m/m. Relying entirely on the screws and using this practical range of stiffness, a parametric study using Eurocode 3 design buckling resistance equations on 9 m simply supported span steel beams and beam-columns with span-to-depth ratios of about 10, 15, 20 and 25 was performed. The results indicate that designing such members as fully restrained in fire conditions may lead to unrealistic assumptions and unsafe structures.</p></div>\",\"PeriodicalId\":50445,\"journal\":{\"name\":\"Fire Safety Journal\",\"volume\":\"146 \",\"pages\":\"Article 104172\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2024-05-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S0379711224000857/pdfft?md5=2d0c2fe506d6f9cf48329634efd0e539&pid=1-s2.0-S0379711224000857-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fire Safety Journal\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0379711224000857\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire Safety Journal","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0379711224000857","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
Influence of continuous elastic lateral restraints on beams and beam-columns of steel-timber hybrid structures in fire
With the climate crisis and pursuit of efforts to reduce embodied carbon impacts in the built environment, steel-timber hybrid structures have emerged as a sustainable form of framed construction which offer numerous benefits over the widely used and well-established steel-concrete hybrid structures. However, there are major concerns about the structural fire performance of such systems among various stakeholders in the construction industry, particularly for the design implications in terms of the lateral-torsional buckling behaviour and the degree of lateral restraint mobilised in the steel-to-timber connections. The screws that connect cross-laminated timber slabs to steel beams may provide a certain degree of restraining action in fire. However, further investigations are required to quantify the slip characteristics of such connections. In this study, it was found from existing literature that at the fire limit state, the continuous elastic lateral stiffness available to restrain the beam varies between approximately 500 kN/m/m and 2000 kN/m/m. Relying entirely on the screws and using this practical range of stiffness, a parametric study using Eurocode 3 design buckling resistance equations on 9 m simply supported span steel beams and beam-columns with span-to-depth ratios of about 10, 15, 20 and 25 was performed. The results indicate that designing such members as fully restrained in fire conditions may lead to unrealistic assumptions and unsafe structures.
期刊介绍:
Fire Safety Journal is the leading publication dealing with all aspects of fire safety engineering. Its scope is purposefully wide, as it is deemed important to encourage papers from all sources within this multidisciplinary subject, thus providing a forum for its further development as a distinct engineering discipline. This is an essential step towards gaining a status equal to that enjoyed by the other engineering disciplines.