火灾-火焰温度和持续时间对带有施工缝的钢筋混凝土梁行为的影响

IF 1.7 Q2 ENGINEERING, MULTIDISCIPLINARY
Ahmed A. Abbood, Majid M. Kharnoob
{"title":"火灾-火焰温度和持续时间对带有施工缝的钢筋混凝土梁行为的影响","authors":"Ahmed A. Abbood, Majid M. Kharnoob","doi":"10.31026/j.eng.2024.05.09","DOIUrl":null,"url":null,"abstract":"Structural members' durability and strength depend on the member’s fire resistance. This study simulates the structural response of a reinforced concrete beam with a construction joint exposed to fire. The commercial finite element software ABAQUS was used to validate the laboratory findings. The testing program tested five reinforced concrete beams with the dimensions of (200x300x2700 mm), having identical reinforcing details and a concrete compressive strength (fc'=35 MPa). These beams had a 45° angled connection at the center. Four beams were exposed to fire flames at two temperature levels (600 °C and 800 °C) and for 1.0 and 2.0 hr. periods, respectively. The fifth beam is the control beam that was not exposed to fire. Laboratory results show that the worst exposure on the beam’s construction joint was at 800 °C with an exposure period of 2 hrs. This exposure reduces the bond between the joint’s two surfaces, creating a slipping effect in which disconnection occurs after loading. After 1 and 2 hours of exposure to fire at 600 °C, the residual flexural strength was 85% and 72% of that of the control beam, respectively.  Whereas, beams exposed to fire for 1 and 2 hours at 800 °C showed flexural strengths lower than the control beam at 41% and 28%, respectively.  Regarding the modulus of elasticity and compressive strength, they both showed residual values of (63.5, 59.2, 50.9, and 47%), and (28, 25, 19, and 16%), respectively.","PeriodicalId":15716,"journal":{"name":"Journal of Engineering","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of Fire-Flame Temperature and Duration on the Behavior of Reinforced Concrete Beams with Construction Joints\",\"authors\":\"Ahmed A. Abbood, Majid M. Kharnoob\",\"doi\":\"10.31026/j.eng.2024.05.09\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Structural members' durability and strength depend on the member’s fire resistance. This study simulates the structural response of a reinforced concrete beam with a construction joint exposed to fire. The commercial finite element software ABAQUS was used to validate the laboratory findings. The testing program tested five reinforced concrete beams with the dimensions of (200x300x2700 mm), having identical reinforcing details and a concrete compressive strength (fc'=35 MPa). These beams had a 45° angled connection at the center. Four beams were exposed to fire flames at two temperature levels (600 °C and 800 °C) and for 1.0 and 2.0 hr. periods, respectively. The fifth beam is the control beam that was not exposed to fire. Laboratory results show that the worst exposure on the beam’s construction joint was at 800 °C with an exposure period of 2 hrs. This exposure reduces the bond between the joint’s two surfaces, creating a slipping effect in which disconnection occurs after loading. After 1 and 2 hours of exposure to fire at 600 °C, the residual flexural strength was 85% and 72% of that of the control beam, respectively.  Whereas, beams exposed to fire for 1 and 2 hours at 800 °C showed flexural strengths lower than the control beam at 41% and 28%, respectively.  Regarding the modulus of elasticity and compressive strength, they both showed residual values of (63.5, 59.2, 50.9, and 47%), and (28, 25, 19, and 16%), respectively.\",\"PeriodicalId\":15716,\"journal\":{\"name\":\"Journal of Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31026/j.eng.2024.05.09\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31026/j.eng.2024.05.09","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

结构构件的耐久性和强度取决于构件的耐火性能。本研究模拟了带有施工缝的钢筋混凝土梁在火灾中的结构响应。商用有限元软件 ABAQUS 用于验证实验室研究结果。测试程序测试了五根钢筋混凝土梁,其尺寸为(200x300x2700 毫米),具有相同的钢筋细节和混凝土抗压强度(fc'=35 兆帕)。这些梁的中心呈 45° 角连接。四根横梁分别暴露在两个温度级别(600 °C 和 800 °C)的火焰中,时间分别为 1.0 小时和 2.0 小时。第五根横梁是对照横梁,没有暴露在火焰中。实验室结果表明,梁的结构接缝最严重的暴露温度为 800 °C,暴露时间为 2 小时。这种暴露降低了接合处两个表面之间的粘合力,产生了滑动效应,在加载后会发生断开。在 600 °C的火焰中暴露 1 小时和 2 小时后,残余抗弯强度分别是对照梁的 85% 和 72%。 而在 800 °C的火焰中暴露 1 和 2 小时后,梁的抗弯强度分别比对照梁低 41% 和 28%。 弹性模量和抗压强度的残余值分别为(63.5、59.2、50.9 和 47%)和(28、25、19 和 16%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of Fire-Flame Temperature and Duration on the Behavior of Reinforced Concrete Beams with Construction Joints
Structural members' durability and strength depend on the member’s fire resistance. This study simulates the structural response of a reinforced concrete beam with a construction joint exposed to fire. The commercial finite element software ABAQUS was used to validate the laboratory findings. The testing program tested five reinforced concrete beams with the dimensions of (200x300x2700 mm), having identical reinforcing details and a concrete compressive strength (fc'=35 MPa). These beams had a 45° angled connection at the center. Four beams were exposed to fire flames at two temperature levels (600 °C and 800 °C) and for 1.0 and 2.0 hr. periods, respectively. The fifth beam is the control beam that was not exposed to fire. Laboratory results show that the worst exposure on the beam’s construction joint was at 800 °C with an exposure period of 2 hrs. This exposure reduces the bond between the joint’s two surfaces, creating a slipping effect in which disconnection occurs after loading. After 1 and 2 hours of exposure to fire at 600 °C, the residual flexural strength was 85% and 72% of that of the control beam, respectively.  Whereas, beams exposed to fire for 1 and 2 hours at 800 °C showed flexural strengths lower than the control beam at 41% and 28%, respectively.  Regarding the modulus of elasticity and compressive strength, they both showed residual values of (63.5, 59.2, 50.9, and 47%), and (28, 25, 19, and 16%), respectively.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Engineering
Journal of Engineering ENGINEERING, MULTIDISCIPLINARY-
CiteScore
4.20
自引率
0.00%
发文量
68
期刊介绍: Journal of Engineering is a peer-reviewed, Open Access journal that publishes original research articles as well as review articles in several areas of engineering. The subject areas covered by the journal are: - Chemical Engineering - Civil Engineering - Computer Engineering - Electrical Engineering - Industrial Engineering - Mechanical Engineering
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信