衡量智能电网数据完整性攻击脆弱性的信息论指标

IF 2.4 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC
IET Smart Grid Pub Date : 2024-05-09 DOI:10.1049/stg2.12163
Xiuzhen Ye, Iñaki Esnaola, Samir M. Perlaza, Robert F. Harrison
{"title":"衡量智能电网数据完整性攻击脆弱性的信息论指标","authors":"Xiuzhen Ye,&nbsp;Iñaki Esnaola,&nbsp;Samir M. Perlaza,&nbsp;Robert F. Harrison","doi":"10.1049/stg2.12163","DOIUrl":null,"url":null,"abstract":"<p>A novel metric that describes the vulnerability of the measurements in power systems to data integrity attacks is proposed. The new metric, coined vulnerability index (VuIx), leverages information theoretic measures to assess the attack effect in terms of the fundamental limits of the disruption and detection tradeoff. The result of computing the VuIx of the measurements in the system yields an ordering of their vulnerability based on the degree of exposure to data integrity attacks. This new framework is used to assess the measurement vulnerability of IEEE 9-bus and 30-bus test systems and it is observed that power injection measurements are significantly more vulnerable to data integrity attacks than power flow measurements. A detailed numerical evaluation of the VuIx values for IEEE test systems is provided.</p>","PeriodicalId":36490,"journal":{"name":"IET Smart Grid","volume":"7 5","pages":"583-592"},"PeriodicalIF":2.4000,"publicationDate":"2024-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/stg2.12163","citationCount":"0","resultStr":"{\"title\":\"An information theoretic metric for measurement vulnerability to data integrity attacks on smart grids\",\"authors\":\"Xiuzhen Ye,&nbsp;Iñaki Esnaola,&nbsp;Samir M. Perlaza,&nbsp;Robert F. Harrison\",\"doi\":\"10.1049/stg2.12163\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>A novel metric that describes the vulnerability of the measurements in power systems to data integrity attacks is proposed. The new metric, coined vulnerability index (VuIx), leverages information theoretic measures to assess the attack effect in terms of the fundamental limits of the disruption and detection tradeoff. The result of computing the VuIx of the measurements in the system yields an ordering of their vulnerability based on the degree of exposure to data integrity attacks. This new framework is used to assess the measurement vulnerability of IEEE 9-bus and 30-bus test systems and it is observed that power injection measurements are significantly more vulnerable to data integrity attacks than power flow measurements. A detailed numerical evaluation of the VuIx values for IEEE test systems is provided.</p>\",\"PeriodicalId\":36490,\"journal\":{\"name\":\"IET Smart Grid\",\"volume\":\"7 5\",\"pages\":\"583-592\"},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2024-05-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1049/stg2.12163\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IET Smart Grid\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1049/stg2.12163\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IET Smart Grid","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/stg2.12163","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

本文提出了一种描述电力系统中的测量数据易受数据完整性攻击影响程度的新指标。新指标被称为脆弱性指数 (VuIx),它利用信息论措施,从破坏和检测权衡的基本限制角度评估攻击效果。计算系统中测量值的 VuIx 的结果是,根据暴露于数据完整性攻击的程度对它们的脆弱性进行排序。这个新框架被用于评估 IEEE 9 总线和 30 总线测试系统的测量脆弱性,结果发现,功率注入测量比功率流测量更容易受到数据完整性攻击。本文提供了 IEEE 测试系统 VuIx 值的详细数值评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

An information theoretic metric for measurement vulnerability to data integrity attacks on smart grids

An information theoretic metric for measurement vulnerability to data integrity attacks on smart grids

A novel metric that describes the vulnerability of the measurements in power systems to data integrity attacks is proposed. The new metric, coined vulnerability index (VuIx), leverages information theoretic measures to assess the attack effect in terms of the fundamental limits of the disruption and detection tradeoff. The result of computing the VuIx of the measurements in the system yields an ordering of their vulnerability based on the degree of exposure to data integrity attacks. This new framework is used to assess the measurement vulnerability of IEEE 9-bus and 30-bus test systems and it is observed that power injection measurements are significantly more vulnerable to data integrity attacks than power flow measurements. A detailed numerical evaluation of the VuIx values for IEEE test systems is provided.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IET Smart Grid
IET Smart Grid Computer Science-Computer Networks and Communications
CiteScore
6.70
自引率
4.30%
发文量
41
审稿时长
29 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信