{"title":"利用机器学习对电声信号进行火花放电参数诊断","authors":"Jun Xiong, Shiyu Lu, Xiaoming Liu, Wenjun Zhou, Xiaoming Zha, Xuekai Pei","doi":"10.1088/2058-6272/ad495e","DOIUrl":null,"url":null,"abstract":"\n Discharge plasma parameter measurement is a key focus in low-temperature plasma research. Traditional diagnostics often require costly equipment, whereas electro-acoustic signals provide a rich, non-invasive, and less complex source of discharge information. This study harnesses machine learning to decode these signals. It establishes links between electro-acoustic signals and gas discharge parameters, such as power and distance, thus streamlining the prediction process. By building a spark discharge platform to collect electro-acoustic signals and implementing a series of acoustic signal processing techniques, the Mel-Frequency Cepstral Coefficients (MFCCs) of the acoustic signals are extracted to construct the predictors. Three machine learning models (Linear Regression, k-Nearest Neighbors, and Random Forest) are introduced and applied to the predictors to achieve real-time rapid diagnostic measurement of typical spark discharge power and discharge distance. All models display impressive performance in prediction precision and fitting abilities. Among them, the k-Nearest Neighbors model shows the best performance on discharge power prediction with the lowest mean square error (MSE=0.00571) and the highest R-squared value (R^2=0.93877). The experimental results show that the relationship between the electro-acoustic signal and the gas discharge power and distance can be effectively constructed based on the machine learning algorithm, which provides a new idea and basis for the online monitoring and real-time diagnosis of plasma parameters.","PeriodicalId":506986,"journal":{"name":"Plasma Science and Technology","volume":" 8","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Machine learning for parameters diagnosis of spark discharge by electro-acoustic signal\",\"authors\":\"Jun Xiong, Shiyu Lu, Xiaoming Liu, Wenjun Zhou, Xiaoming Zha, Xuekai Pei\",\"doi\":\"10.1088/2058-6272/ad495e\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Discharge plasma parameter measurement is a key focus in low-temperature plasma research. Traditional diagnostics often require costly equipment, whereas electro-acoustic signals provide a rich, non-invasive, and less complex source of discharge information. This study harnesses machine learning to decode these signals. It establishes links between electro-acoustic signals and gas discharge parameters, such as power and distance, thus streamlining the prediction process. By building a spark discharge platform to collect electro-acoustic signals and implementing a series of acoustic signal processing techniques, the Mel-Frequency Cepstral Coefficients (MFCCs) of the acoustic signals are extracted to construct the predictors. Three machine learning models (Linear Regression, k-Nearest Neighbors, and Random Forest) are introduced and applied to the predictors to achieve real-time rapid diagnostic measurement of typical spark discharge power and discharge distance. All models display impressive performance in prediction precision and fitting abilities. Among them, the k-Nearest Neighbors model shows the best performance on discharge power prediction with the lowest mean square error (MSE=0.00571) and the highest R-squared value (R^2=0.93877). The experimental results show that the relationship between the electro-acoustic signal and the gas discharge power and distance can be effectively constructed based on the machine learning algorithm, which provides a new idea and basis for the online monitoring and real-time diagnosis of plasma parameters.\",\"PeriodicalId\":506986,\"journal\":{\"name\":\"Plasma Science and Technology\",\"volume\":\" 8\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-05-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Plasma Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/2058-6272/ad495e\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Plasma Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2058-6272/ad495e","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Machine learning for parameters diagnosis of spark discharge by electro-acoustic signal
Discharge plasma parameter measurement is a key focus in low-temperature plasma research. Traditional diagnostics often require costly equipment, whereas electro-acoustic signals provide a rich, non-invasive, and less complex source of discharge information. This study harnesses machine learning to decode these signals. It establishes links between electro-acoustic signals and gas discharge parameters, such as power and distance, thus streamlining the prediction process. By building a spark discharge platform to collect electro-acoustic signals and implementing a series of acoustic signal processing techniques, the Mel-Frequency Cepstral Coefficients (MFCCs) of the acoustic signals are extracted to construct the predictors. Three machine learning models (Linear Regression, k-Nearest Neighbors, and Random Forest) are introduced and applied to the predictors to achieve real-time rapid diagnostic measurement of typical spark discharge power and discharge distance. All models display impressive performance in prediction precision and fitting abilities. Among them, the k-Nearest Neighbors model shows the best performance on discharge power prediction with the lowest mean square error (MSE=0.00571) and the highest R-squared value (R^2=0.93877). The experimental results show that the relationship between the electro-acoustic signal and the gas discharge power and distance can be effectively constructed based on the machine learning algorithm, which provides a new idea and basis for the online monitoring and real-time diagnosis of plasma parameters.