改进三维引导下桡骨远端矫正截骨术中的标准伏板固定:评估一种垫片器械。

IF 1 4区 医学 Q3 ORTHOPEDICS
Emilia Gryska, Katleen Libberecht, Charlotte Stor Swinkels, Peter Axelsson, Per Fredrikson, Anders Björkman
{"title":"改进三维引导下桡骨远端矫正截骨术中的标准伏板固定:评估一种垫片器械。","authors":"Emilia Gryska, Katleen Libberecht, Charlotte Stor Swinkels, Peter Axelsson, Per Fredrikson, Anders Björkman","doi":"10.2340/jphs.v59.39839","DOIUrl":null,"url":null,"abstract":"<p><p>Standard volar plates often do not fit the surface of the malunited distal radius after osteotomy, necessitating an offset angle for accurate volar tilt correction. The correction can be achieved if the plate is held at the correct angle when the distal screws are locked. With the advantage of 3D surgical planning and patient-specific instruments, we developed a shim instrument to assist the surgeon in securing the plate at the intended angle when locking the distal screws, and evaluated radiological results. Five female patients aged 63-74 with dorsally angulated extra-articular malunions underwent surgery using 3D-printed guides and the shim instrument. The plate position, drilling guide alignment, screw placements, and distal radius correction on postoperative CTs were compared with the surgical plans. Errors were measured using an anatomical coordinate system, and standard 2D radiographic measures were extracted. Preoperative dorsal tilt ranged from 16° to 35°, and postoperative volar tilt from 1° to 11°. 3D analysis revealed mean absolute correction errors of 6.1° in volar tilt, 1.6° in radial inclination, and 0.6 mm in ulnar variance. The volar tilt error due to the shim instrument, indicated by the mean angle error of the distal screws to the plate, was 2.1° but varied across the five patients. Settling of the distal radius, due to tension during and after reduction, further contributed to a mean loss of 3.5° in volar tilt. The shim instrument helped with securing plates at the intended angle; however, further correction improvements should consider the tension between the fragments of osteoporotic bone.</p>","PeriodicalId":16847,"journal":{"name":"Journal of Plastic Surgery and Hand Surgery","volume":"59 ","pages":"46-52"},"PeriodicalIF":1.0000,"publicationDate":"2024-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Improving standard volar plate fixation in 3D-guided corrective osteotomy of the distal radius: evaluation of a shim instrument.\",\"authors\":\"Emilia Gryska, Katleen Libberecht, Charlotte Stor Swinkels, Peter Axelsson, Per Fredrikson, Anders Björkman\",\"doi\":\"10.2340/jphs.v59.39839\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Standard volar plates often do not fit the surface of the malunited distal radius after osteotomy, necessitating an offset angle for accurate volar tilt correction. The correction can be achieved if the plate is held at the correct angle when the distal screws are locked. With the advantage of 3D surgical planning and patient-specific instruments, we developed a shim instrument to assist the surgeon in securing the plate at the intended angle when locking the distal screws, and evaluated radiological results. Five female patients aged 63-74 with dorsally angulated extra-articular malunions underwent surgery using 3D-printed guides and the shim instrument. The plate position, drilling guide alignment, screw placements, and distal radius correction on postoperative CTs were compared with the surgical plans. Errors were measured using an anatomical coordinate system, and standard 2D radiographic measures were extracted. Preoperative dorsal tilt ranged from 16° to 35°, and postoperative volar tilt from 1° to 11°. 3D analysis revealed mean absolute correction errors of 6.1° in volar tilt, 1.6° in radial inclination, and 0.6 mm in ulnar variance. The volar tilt error due to the shim instrument, indicated by the mean angle error of the distal screws to the plate, was 2.1° but varied across the five patients. Settling of the distal radius, due to tension during and after reduction, further contributed to a mean loss of 3.5° in volar tilt. The shim instrument helped with securing plates at the intended angle; however, further correction improvements should consider the tension between the fragments of osteoporotic bone.</p>\",\"PeriodicalId\":16847,\"journal\":{\"name\":\"Journal of Plastic Surgery and Hand Surgery\",\"volume\":\"59 \",\"pages\":\"46-52\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-05-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Plastic Surgery and Hand Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2340/jphs.v59.39839\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Plastic Surgery and Hand Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2340/jphs.v59.39839","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

截骨后,标准的桡骨侧板往往与畸形桡骨远端表面不吻合,因此需要偏移角度以准确矫正桡骨侧倾。如果在锁定远端螺钉时将钢板固定在正确的角度,就能实现矫正。借助三维手术规划和患者专用器械的优势,我们开发了一种垫片器械,以协助外科医生在锁定远端螺钉时将钢板固定在预定角度,并对放射学结果进行了评估。五名年龄在 63-74 岁之间、患有背侧成角关节外错构瘤的女性患者使用 3D 打印导板和垫片器械接受了手术。术后 CT 显示的钢板位置、钻孔导板对齐情况、螺钉位置和桡骨远端矫正情况与手术计划进行了比较。使用解剖坐标系测量误差,并提取标准的二维射线测量值。术前背侧倾斜从16°到35°不等,术后外侧倾斜从1°到11°不等。三维分析显示,平均绝对校正误差为:伏侧倾斜 6.1°,桡侧倾斜 1.6°,尺侧偏差 0.6 毫米。由垫片器械引起的外侧倾斜误差(由远端螺钉与钢板的平均角度误差表示)为 2.1°,但五名患者的误差各不相同。桡骨远端在截骨过程中和截骨后由于张力而产生的沉降进一步导致了3.5°的平均侧倾损失。垫片器械有助于将钢板固定在预定角度;但是,进一步的矫正改进应考虑骨质疏松骨片之间的张力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Improving standard volar plate fixation in 3D-guided corrective osteotomy of the distal radius: evaluation of a shim instrument.

Standard volar plates often do not fit the surface of the malunited distal radius after osteotomy, necessitating an offset angle for accurate volar tilt correction. The correction can be achieved if the plate is held at the correct angle when the distal screws are locked. With the advantage of 3D surgical planning and patient-specific instruments, we developed a shim instrument to assist the surgeon in securing the plate at the intended angle when locking the distal screws, and evaluated radiological results. Five female patients aged 63-74 with dorsally angulated extra-articular malunions underwent surgery using 3D-printed guides and the shim instrument. The plate position, drilling guide alignment, screw placements, and distal radius correction on postoperative CTs were compared with the surgical plans. Errors were measured using an anatomical coordinate system, and standard 2D radiographic measures were extracted. Preoperative dorsal tilt ranged from 16° to 35°, and postoperative volar tilt from 1° to 11°. 3D analysis revealed mean absolute correction errors of 6.1° in volar tilt, 1.6° in radial inclination, and 0.6 mm in ulnar variance. The volar tilt error due to the shim instrument, indicated by the mean angle error of the distal screws to the plate, was 2.1° but varied across the five patients. Settling of the distal radius, due to tension during and after reduction, further contributed to a mean loss of 3.5° in volar tilt. The shim instrument helped with securing plates at the intended angle; however, further correction improvements should consider the tension between the fragments of osteoporotic bone.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.10
自引率
0.00%
发文量
108
审稿时长
6-12 weeks
期刊介绍: The purpose of the Journal of Plastic Surgery and Hand Surgery is to serve as an international forum for plastic surgery, hand surgery and related research. Interest is focused on original articles on basic research and clinical evaluation. The scope of the journal comprises: • Articles concerning operative methods and follow-up studies • Research articles on subjects related to plastic and hand surgery • Articles on cranio-maxillofacial surgery, including cleft lip and palate surgery. Extended issues are published occasionally, dealing with special topics such as microvascular surgery, craniofacial surgery, or burns. Supplements, usually doctoral theses, may also be published. The journal is published for the Acta Chirurgica Scandinavica society and sponsored by the Key Foundation, Sweden. The journal was previously published as Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信