{"title":"半月板置换术的现状。","authors":"B S van Minnen, T G van Tienen","doi":"10.1007/s12178-024-09902-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose of review: </strong>The field of meniscus replacement is changing continuously, with new devices emerging and others disappearing from the market. With the current tendency to preserve the knee joint, meniscus implants may become more relevant than ever. The purpose of this review is to provide an overview of the current state of partial and total meniscus replacements that have been developed beyond the academic phase. The available clinical and pre-clinical data is evaluated, and omissions are identified.</p><p><strong>Recent findings: </strong>Recent systematic reviews have shown a lack of homogenous clinical data on the CMI and Actifit meniscal scaffolds, especially regarding long-term performance without concomitant surgical interventions. Clinical studies on the medial total meniscus prostheses NUsurface and Artimis are ongoing, with the NUsurface being several years ahead. New techniques for meniscus replacement are rapidly developing, including the Artimis lateral meniscus prosthesis and the MeniscoFix 3D-printed scaffold. All evaluated clinical studies point towards improved clinical outcomes after implantation of partial and total meniscus replacements. Long-term data on survival and performance is of low quality for CMI and Actifit and is unavailable yet for NUsurface and Artimis. It is of major importance that future research focuses on optimizing fixation methods and identifying the optimal treatment strategy for each patient group. New techniques for total and partial replacement of the medial and lateral meniscus will be followed with interest.</p>","PeriodicalId":10950,"journal":{"name":"Current Reviews in Musculoskeletal Medicine","volume":" ","pages":"293-302"},"PeriodicalIF":2.9000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11219664/pdf/","citationCount":"0","resultStr":"{\"title\":\"The Current State of Meniscus Replacements.\",\"authors\":\"B S van Minnen, T G van Tienen\",\"doi\":\"10.1007/s12178-024-09902-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose of review: </strong>The field of meniscus replacement is changing continuously, with new devices emerging and others disappearing from the market. With the current tendency to preserve the knee joint, meniscus implants may become more relevant than ever. The purpose of this review is to provide an overview of the current state of partial and total meniscus replacements that have been developed beyond the academic phase. The available clinical and pre-clinical data is evaluated, and omissions are identified.</p><p><strong>Recent findings: </strong>Recent systematic reviews have shown a lack of homogenous clinical data on the CMI and Actifit meniscal scaffolds, especially regarding long-term performance without concomitant surgical interventions. Clinical studies on the medial total meniscus prostheses NUsurface and Artimis are ongoing, with the NUsurface being several years ahead. New techniques for meniscus replacement are rapidly developing, including the Artimis lateral meniscus prosthesis and the MeniscoFix 3D-printed scaffold. All evaluated clinical studies point towards improved clinical outcomes after implantation of partial and total meniscus replacements. Long-term data on survival and performance is of low quality for CMI and Actifit and is unavailable yet for NUsurface and Artimis. It is of major importance that future research focuses on optimizing fixation methods and identifying the optimal treatment strategy for each patient group. New techniques for total and partial replacement of the medial and lateral meniscus will be followed with interest.</p>\",\"PeriodicalId\":10950,\"journal\":{\"name\":\"Current Reviews in Musculoskeletal Medicine\",\"volume\":\" \",\"pages\":\"293-302\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11219664/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Reviews in Musculoskeletal Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s12178-024-09902-1\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Reviews in Musculoskeletal Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s12178-024-09902-1","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/14 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Purpose of review: The field of meniscus replacement is changing continuously, with new devices emerging and others disappearing from the market. With the current tendency to preserve the knee joint, meniscus implants may become more relevant than ever. The purpose of this review is to provide an overview of the current state of partial and total meniscus replacements that have been developed beyond the academic phase. The available clinical and pre-clinical data is evaluated, and omissions are identified.
Recent findings: Recent systematic reviews have shown a lack of homogenous clinical data on the CMI and Actifit meniscal scaffolds, especially regarding long-term performance without concomitant surgical interventions. Clinical studies on the medial total meniscus prostheses NUsurface and Artimis are ongoing, with the NUsurface being several years ahead. New techniques for meniscus replacement are rapidly developing, including the Artimis lateral meniscus prosthesis and the MeniscoFix 3D-printed scaffold. All evaluated clinical studies point towards improved clinical outcomes after implantation of partial and total meniscus replacements. Long-term data on survival and performance is of low quality for CMI and Actifit and is unavailable yet for NUsurface and Artimis. It is of major importance that future research focuses on optimizing fixation methods and identifying the optimal treatment strategy for each patient group. New techniques for total and partial replacement of the medial and lateral meniscus will be followed with interest.
期刊介绍:
This journal intends to review the most significant recent developments in the field of musculoskeletal medicine. By providing clear, insightful, balanced contributions by expert world-renowned authors, the journal aims to serve all those involved in the diagnosis, treatment, management, and prevention of musculoskeletal-related conditions.
We accomplish this aim by appointing authorities to serve as Section Editors in key subject areas, such as rehabilitation of the knee and hip, sports medicine, trauma, pediatrics, health policy, customization in arthroplasty, and rheumatology. Section Editors, in turn, select topics for which leading experts contribute comprehensive review articles that emphasize new developments and recently published papers of major importance, highlighted by annotated reference lists. We also provide commentaries from well-known figures in the field, and an Editorial Board of more than 20 diverse members suggests topics of special interest to their country/region and ensures that topics are current and include emerging research.