{"title":"基于改性碳点双发射比率测定法的新策略同时检测卡比多巴和左旋多巴","authors":"Sasan Abbasi Majd, Soheila Kashanian, Zahra Shekarbeygi, Mahsa Babaei","doi":"10.1002/bab.2595","DOIUrl":null,"url":null,"abstract":"<p>Rapid control of the content of Parkinson's drugs in biological fluids and pharmaceutical formulations is of great importance because changes in the concentration of these drugs affect their bioavailability and biopharmaceutical properties. Therefore, we presented a simple and convenient method for the ratiometric detection of carbidopa and levodopa for carbon dots (CDs) dual-fluorescent emission. Dual-emission CDs were prepared from chitosan using a microwave method, following which the surface was chemically modified with terephthalaldehyde. CDs had two strong well-separated peaks at 445 and 510 nm. The relative measurement of carbidopa and levodopa was based on the static extinction of CDs at 445 nm and increase at 510 nm, respectively. The linear range for carbidopa measurement was 2.5–300 nM, with a limit of detection (LOD) of 2.1 nM, and a relative standard deviation (RSD) of 1.68%. Further, the linear range for levodopa measurement was equal to 3.0–400 nM, with LOD and RSD% of 2.8 nM and 3.5%, respectively. Also, selectivity of ratiometric sensor in the presence of interferences was investigated, which showed that the recovery of carbidopa and levodopa in serum and urine samples has changed between 96.80% and 116.24% with RSD% 0.11–0.77. CDs also provided good results for the determination of carbidopa and levodopa in real samples, and had high selectivity in the presence of possible interferences.</p>","PeriodicalId":9274,"journal":{"name":"Biotechnology and applied biochemistry","volume":"71 5","pages":"1032-1043"},"PeriodicalIF":3.2000,"publicationDate":"2024-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simultaneous sensing of carbidopa and levodopa by a novel strategy based on dual-emission ratiometric assay of modified carbon dots\",\"authors\":\"Sasan Abbasi Majd, Soheila Kashanian, Zahra Shekarbeygi, Mahsa Babaei\",\"doi\":\"10.1002/bab.2595\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Rapid control of the content of Parkinson's drugs in biological fluids and pharmaceutical formulations is of great importance because changes in the concentration of these drugs affect their bioavailability and biopharmaceutical properties. Therefore, we presented a simple and convenient method for the ratiometric detection of carbidopa and levodopa for carbon dots (CDs) dual-fluorescent emission. Dual-emission CDs were prepared from chitosan using a microwave method, following which the surface was chemically modified with terephthalaldehyde. CDs had two strong well-separated peaks at 445 and 510 nm. The relative measurement of carbidopa and levodopa was based on the static extinction of CDs at 445 nm and increase at 510 nm, respectively. The linear range for carbidopa measurement was 2.5–300 nM, with a limit of detection (LOD) of 2.1 nM, and a relative standard deviation (RSD) of 1.68%. Further, the linear range for levodopa measurement was equal to 3.0–400 nM, with LOD and RSD% of 2.8 nM and 3.5%, respectively. Also, selectivity of ratiometric sensor in the presence of interferences was investigated, which showed that the recovery of carbidopa and levodopa in serum and urine samples has changed between 96.80% and 116.24% with RSD% 0.11–0.77. CDs also provided good results for the determination of carbidopa and levodopa in real samples, and had high selectivity in the presence of possible interferences.</p>\",\"PeriodicalId\":9274,\"journal\":{\"name\":\"Biotechnology and applied biochemistry\",\"volume\":\"71 5\",\"pages\":\"1032-1043\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-05-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biotechnology and applied biochemistry\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/bab.2595\",\"RegionNum\":4,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMISTRY & MOLECULAR BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotechnology and applied biochemistry","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/bab.2595","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
Simultaneous sensing of carbidopa and levodopa by a novel strategy based on dual-emission ratiometric assay of modified carbon dots
Rapid control of the content of Parkinson's drugs in biological fluids and pharmaceutical formulations is of great importance because changes in the concentration of these drugs affect their bioavailability and biopharmaceutical properties. Therefore, we presented a simple and convenient method for the ratiometric detection of carbidopa and levodopa for carbon dots (CDs) dual-fluorescent emission. Dual-emission CDs were prepared from chitosan using a microwave method, following which the surface was chemically modified with terephthalaldehyde. CDs had two strong well-separated peaks at 445 and 510 nm. The relative measurement of carbidopa and levodopa was based on the static extinction of CDs at 445 nm and increase at 510 nm, respectively. The linear range for carbidopa measurement was 2.5–300 nM, with a limit of detection (LOD) of 2.1 nM, and a relative standard deviation (RSD) of 1.68%. Further, the linear range for levodopa measurement was equal to 3.0–400 nM, with LOD and RSD% of 2.8 nM and 3.5%, respectively. Also, selectivity of ratiometric sensor in the presence of interferences was investigated, which showed that the recovery of carbidopa and levodopa in serum and urine samples has changed between 96.80% and 116.24% with RSD% 0.11–0.77. CDs also provided good results for the determination of carbidopa and levodopa in real samples, and had high selectivity in the presence of possible interferences.
期刊介绍:
Published since 1979, Biotechnology and Applied Biochemistry is dedicated to the rapid publication of high quality, significant research at the interface between life sciences and their technological exploitation.
The Editors will consider papers for publication based on their novelty and impact as well as their contribution to the advancement of medical biotechnology and industrial biotechnology, covering cutting-edge research in synthetic biology, systems biology, metabolic engineering, bioengineering, biomaterials, biosensing, and nano-biotechnology.