儿科心脏介入手术中医务人员的剂量估算。

IF 1.4 4区 环境科学与生态学 Q4 ENVIRONMENTAL SCIENCES
Maryanna Regina Roberto, Luiz M A Leite, Arícia R P Cruz, Helen Khoury, Vinícius S M de Barros, Juliana R Neves, Jéssica M Cartaxo, Carlos Ubeda, Viviane K Asfora
{"title":"儿科心脏介入手术中医务人员的剂量估算。","authors":"Maryanna Regina Roberto, Luiz M A Leite, Arícia R P Cruz, Helen Khoury, Vinícius S M de Barros, Juliana R Neves, Jéssica M Cartaxo, Carlos Ubeda, Viviane K Asfora","doi":"10.1088/1361-6498/ad4905","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this study is to evaluate the occupational doses (eye lens, extremities and whole body) in paediatric cardiac interventional and diagnostic catheterization procedures performed in a paediatric reference hospital located in Recife, Pernambuco. For eye lens dosimetry, the results show that the left eye receives a higher dose than the right eye, and there is a small difference between the doses received during diagnostic (D) and therapeutic (T) procedures. The extrapolated annual values for the most exposed eye are close to the annual limit. For doses to the hands, it was observed that in a significant number of procedures (37 out of 45 therapeutic procedures, or 82%) at least one hand of the physician was exposed to the primary beam. During diagnostic procedures, the physician's hand was in the radiation field in 11 of the 17 catheterization procedures (65%). This resulted in a 10-fold increase in dose to the hands. The results underscore the need for optimization of radiation safety and continued efforts to engage staff in a radiation safety culture.</p>","PeriodicalId":50068,"journal":{"name":"Journal of Radiological Protection","volume":" ","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2024-05-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Medical staff dose estimation during pediatric cardiac interventional procedures.\",\"authors\":\"Maryanna Regina Roberto, Luiz M A Leite, Arícia R P Cruz, Helen Khoury, Vinícius S M de Barros, Juliana R Neves, Jéssica M Cartaxo, Carlos Ubeda, Viviane K Asfora\",\"doi\":\"10.1088/1361-6498/ad4905\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The purpose of this study is to evaluate the occupational doses (eye lens, extremities and whole body) in paediatric cardiac interventional and diagnostic catheterization procedures performed in a paediatric reference hospital located in Recife, Pernambuco. For eye lens dosimetry, the results show that the left eye receives a higher dose than the right eye, and there is a small difference between the doses received during diagnostic (D) and therapeutic (T) procedures. The extrapolated annual values for the most exposed eye are close to the annual limit. For doses to the hands, it was observed that in a significant number of procedures (37 out of 45 therapeutic procedures, or 82%) at least one hand of the physician was exposed to the primary beam. During diagnostic procedures, the physician's hand was in the radiation field in 11 of the 17 catheterization procedures (65%). This resulted in a 10-fold increase in dose to the hands. The results underscore the need for optimization of radiation safety and continued efforts to engage staff in a radiation safety culture.</p>\",\"PeriodicalId\":50068,\"journal\":{\"name\":\"Journal of Radiological Protection\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-05-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Radiological Protection\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1088/1361-6498/ad4905\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiological Protection","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1088/1361-6498/ad4905","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是评估在伯南布哥州累西腓市一家儿科参考医院进行的儿科心脏介入和诊断导管手术中的职业剂量(眼球晶状体、四肢和全身)。在眼球晶状体剂量测定方面,结果显示左眼的剂量高于右眼,诊断(D)和治疗(T)过程中的剂量差异很小。推算出的受照射最严重眼睛的年度值接近年度限值。关于手部受到的剂量,据观察,在相当多的治疗过程中(45 个治疗过程中的 37 个,即 82%),医生至少有一只手暴露在主光束中。在诊断过程中,17 个导管插入手术中有 11 个(65%)医生的手处于辐射场中。这导致手部受到的剂量增加了 10 倍。这些结果表明,有必要优化辐射安全,并继续努力让员工参与到辐射安全文化中来。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Medical staff dose estimation during pediatric cardiac interventional procedures.

The purpose of this study is to evaluate the occupational doses (eye lens, extremities and whole body) in paediatric cardiac interventional and diagnostic catheterization procedures performed in a paediatric reference hospital located in Recife, Pernambuco. For eye lens dosimetry, the results show that the left eye receives a higher dose than the right eye, and there is a small difference between the doses received during diagnostic (D) and therapeutic (T) procedures. The extrapolated annual values for the most exposed eye are close to the annual limit. For doses to the hands, it was observed that in a significant number of procedures (37 out of 45 therapeutic procedures, or 82%) at least one hand of the physician was exposed to the primary beam. During diagnostic procedures, the physician's hand was in the radiation field in 11 of the 17 catheterization procedures (65%). This resulted in a 10-fold increase in dose to the hands. The results underscore the need for optimization of radiation safety and continued efforts to engage staff in a radiation safety culture.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Radiological Protection
Journal of Radiological Protection 环境科学-公共卫生、环境卫生与职业卫生
CiteScore
2.60
自引率
26.70%
发文量
137
审稿时长
18-36 weeks
期刊介绍: Journal of Radiological Protection publishes articles on all aspects of radiological protection, including non-ionising as well as ionising radiations. Fields of interest range from research, development and theory to operational matters, education and training. The very wide spectrum of its topics includes: dosimetry, instrument development, specialized measuring techniques, epidemiology, biological effects (in vivo and in vitro) and risk and environmental impact assessments. The journal encourages publication of data and code as well as results.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信