Brittany N Krekeler, Anna Hopkins, Meredith E Tabangin, Mekibib Altaye, Rachel Roberts, Raneh Saadi, Bonnie Martin-Harris, Nicole Rogus-Pulia
{"title":"舌位仪的标准(并发)有效性和临床实用性。","authors":"Brittany N Krekeler, Anna Hopkins, Meredith E Tabangin, Mekibib Altaye, Rachel Roberts, Raneh Saadi, Bonnie Martin-Harris, Nicole Rogus-Pulia","doi":"10.1044/2024_AJSLP-23-00478","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Tongue manometry (i.e., tongue pressure measurement) is a commonly used assessment for patients with suspected oral-motor involvement in swallowing disorders. Availability of lingual manometry has changed in recent years, with the introduction of the Tongueometer device being a more affordable tongue manometry system. The purpose of this study was to test concurrent (criterion) validity of the Tongueometer compared to the current standard reference device, the Iowa Oral Performance Instrument (IOPI).</p><p><strong>Method: </strong>Adults without dysphagia were recruited for participation in this study. Standard lingual measurements (swallowing-related pressures, maximum isometric pressure [MIP], and maximum isometric endurance) were recorded, with the bulb anteriorly placed, with both devices, in a randomized order. The Bland-Altman method was used to determine concurrent (criterion) validity of these measurements compared to the clinical standard IOPI device. A recently available suggested corrective value by Curtis et al. (2023) was also applied, with comparisons made between devices both with and without the Curtis correction.</p><p><strong>Results: </strong>The final sample included 70 adult participants aged 20-89 years (<i>M</i><sub>age</sub> = 52.3 years). Measures with the Tongueometer device were significantly lower when compared with the same measures taken using the IOPI (<i>p</i> < .01) for all measures including MIP, endurance, and swallow pressures. The correction suggested by Curtis and colleagues did not ameliorate these differences.</p><p><strong>Conclusions: </strong>The Tongueometer lingual measurements were consistently lower compared to the IOPI. Clinical use of values taken with the Tongueometer device should be compared to normative data published for each specific device. Available features of each device (e.g., display, bulb texture, technology/application) should be considered when selecting which device to use with an individual patient.</p>","PeriodicalId":49240,"journal":{"name":"American Journal of Speech-Language Pathology","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11253644/pdf/","citationCount":"0","resultStr":"{\"title\":\"Criterion (Concurrent) Validity and Clinical Utility of the Tongueometer Device.\",\"authors\":\"Brittany N Krekeler, Anna Hopkins, Meredith E Tabangin, Mekibib Altaye, Rachel Roberts, Raneh Saadi, Bonnie Martin-Harris, Nicole Rogus-Pulia\",\"doi\":\"10.1044/2024_AJSLP-23-00478\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Tongue manometry (i.e., tongue pressure measurement) is a commonly used assessment for patients with suspected oral-motor involvement in swallowing disorders. Availability of lingual manometry has changed in recent years, with the introduction of the Tongueometer device being a more affordable tongue manometry system. The purpose of this study was to test concurrent (criterion) validity of the Tongueometer compared to the current standard reference device, the Iowa Oral Performance Instrument (IOPI).</p><p><strong>Method: </strong>Adults without dysphagia were recruited for participation in this study. Standard lingual measurements (swallowing-related pressures, maximum isometric pressure [MIP], and maximum isometric endurance) were recorded, with the bulb anteriorly placed, with both devices, in a randomized order. The Bland-Altman method was used to determine concurrent (criterion) validity of these measurements compared to the clinical standard IOPI device. A recently available suggested corrective value by Curtis et al. (2023) was also applied, with comparisons made between devices both with and without the Curtis correction.</p><p><strong>Results: </strong>The final sample included 70 adult participants aged 20-89 years (<i>M</i><sub>age</sub> = 52.3 years). Measures with the Tongueometer device were significantly lower when compared with the same measures taken using the IOPI (<i>p</i> < .01) for all measures including MIP, endurance, and swallow pressures. The correction suggested by Curtis and colleagues did not ameliorate these differences.</p><p><strong>Conclusions: </strong>The Tongueometer lingual measurements were consistently lower compared to the IOPI. Clinical use of values taken with the Tongueometer device should be compared to normative data published for each specific device. Available features of each device (e.g., display, bulb texture, technology/application) should be considered when selecting which device to use with an individual patient.</p>\",\"PeriodicalId\":49240,\"journal\":{\"name\":\"American Journal of Speech-Language Pathology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-07-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11253644/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American Journal of Speech-Language Pathology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1044/2024_AJSLP-23-00478\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Speech-Language Pathology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1044/2024_AJSLP-23-00478","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/9 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
Criterion (Concurrent) Validity and Clinical Utility of the Tongueometer Device.
Purpose: Tongue manometry (i.e., tongue pressure measurement) is a commonly used assessment for patients with suspected oral-motor involvement in swallowing disorders. Availability of lingual manometry has changed in recent years, with the introduction of the Tongueometer device being a more affordable tongue manometry system. The purpose of this study was to test concurrent (criterion) validity of the Tongueometer compared to the current standard reference device, the Iowa Oral Performance Instrument (IOPI).
Method: Adults without dysphagia were recruited for participation in this study. Standard lingual measurements (swallowing-related pressures, maximum isometric pressure [MIP], and maximum isometric endurance) were recorded, with the bulb anteriorly placed, with both devices, in a randomized order. The Bland-Altman method was used to determine concurrent (criterion) validity of these measurements compared to the clinical standard IOPI device. A recently available suggested corrective value by Curtis et al. (2023) was also applied, with comparisons made between devices both with and without the Curtis correction.
Results: The final sample included 70 adult participants aged 20-89 years (Mage = 52.3 years). Measures with the Tongueometer device were significantly lower when compared with the same measures taken using the IOPI (p < .01) for all measures including MIP, endurance, and swallow pressures. The correction suggested by Curtis and colleagues did not ameliorate these differences.
Conclusions: The Tongueometer lingual measurements were consistently lower compared to the IOPI. Clinical use of values taken with the Tongueometer device should be compared to normative data published for each specific device. Available features of each device (e.g., display, bulb texture, technology/application) should be considered when selecting which device to use with an individual patient.
期刊介绍:
Mission: AJSLP publishes peer-reviewed research and other scholarly articles on all aspects of clinical practice in speech-language pathology. The journal is an international outlet for clinical research pertaining to screening, detection, diagnosis, management, and outcomes of communication and swallowing disorders across the lifespan as well as the etiologies and characteristics of these disorders. Because of its clinical orientation, the journal disseminates research findings applicable to diverse aspects of clinical practice in speech-language pathology. AJSLP seeks to advance evidence-based practice by disseminating the results of new studies as well as providing a forum for critical reviews and meta-analyses of previously published work.
Scope: The broad field of speech-language pathology, including aphasia; apraxia of speech and childhood apraxia of speech; aural rehabilitation; augmentative and alternative communication; cognitive impairment; craniofacial disorders; dysarthria; fluency disorders; language disorders in children; speech sound disorders; swallowing, dysphagia, and feeding disorders; and voice disorders.