Jiejia Liu, Sifan Wang, Hai Jin, Qian Wang, Wei Cui
{"title":"DIXE 探测器组件的初步设计","authors":"Jiejia Liu, Sifan Wang, Hai Jin, Qian Wang, Wei Cui","doi":"10.1007/s10909-024-03131-z","DOIUrl":null,"url":null,"abstract":"<div><p>Diffuse X-ray Explorer is a proposed X-ray spectroscopic survey experiment for the China Space Station. Its detector assembly contains the transition edge sensor (TES) microcalorimeter and readout electronics based on the superconducting quantum interference device (SQUID) on the cold stage. The cold stage is thermally connected to the ADR stage, and a Kevlar suspension is used to stabilize and isolate it from the 4 K environment. TES and SQUID are both sensitive to the magnetic field, so a hybrid shielding structure consisting of an outer Cryoperm shield and an inner niobium shield is used to attenuate the magnetic field. In addition, IR/optical/UV photons can produce shot noise and thus degrade the energy resolution of the TES microcalorimeter. A blocking filter assembly is designed to minimize the effects. In it, five filters are mounted at different temperature stages, reducing the probability of IR/optical/UV photons reaching the detector through multiple reflections between filters and absorption. This paper will describe the preliminary design of the detector assembly and its optimization.</p></div>","PeriodicalId":641,"journal":{"name":"Journal of Low Temperature Physics","volume":"216 Part 3","pages":"273 - 284"},"PeriodicalIF":1.1000,"publicationDate":"2024-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Preliminary Design of Detector Assembly for DIXE\",\"authors\":\"Jiejia Liu, Sifan Wang, Hai Jin, Qian Wang, Wei Cui\",\"doi\":\"10.1007/s10909-024-03131-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Diffuse X-ray Explorer is a proposed X-ray spectroscopic survey experiment for the China Space Station. Its detector assembly contains the transition edge sensor (TES) microcalorimeter and readout electronics based on the superconducting quantum interference device (SQUID) on the cold stage. The cold stage is thermally connected to the ADR stage, and a Kevlar suspension is used to stabilize and isolate it from the 4 K environment. TES and SQUID are both sensitive to the magnetic field, so a hybrid shielding structure consisting of an outer Cryoperm shield and an inner niobium shield is used to attenuate the magnetic field. In addition, IR/optical/UV photons can produce shot noise and thus degrade the energy resolution of the TES microcalorimeter. A blocking filter assembly is designed to minimize the effects. In it, five filters are mounted at different temperature stages, reducing the probability of IR/optical/UV photons reaching the detector through multiple reflections between filters and absorption. This paper will describe the preliminary design of the detector assembly and its optimization.</p></div>\",\"PeriodicalId\":641,\"journal\":{\"name\":\"Journal of Low Temperature Physics\",\"volume\":\"216 Part 3\",\"pages\":\"273 - 284\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-05-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Low Temperature Physics\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s10909-024-03131-z\",\"RegionNum\":3,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PHYSICS, APPLIED\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Low Temperature Physics","FirstCategoryId":"101","ListUrlMain":"https://link.springer.com/article/10.1007/s10909-024-03131-z","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSICS, APPLIED","Score":null,"Total":0}
引用次数: 0
摘要
漫射 X 射线探测器是拟在中国空间站上进行的 X 射线光谱勘测实验。其探测器组件包括过渡边缘传感器(TES)微量热计和基于冷级超导量子干涉装置(SQUID)的读出电子装置。冷级与 ADR 级热连接,并使用凯夫拉悬挂装置使其稳定并与 4 K 环境隔离。TES 和 SQUID 对磁场都很敏感,因此使用了由外部 Cryoperm 屏蔽和内部铌屏蔽组成的混合屏蔽结构来衰减磁场。此外,红外/光学/紫外光子会产生射出噪声,从而降低 TES 微量热计的能量分辨率。我们设计了一个阻挡滤波器组件,以最大限度地减少这种影响。其中,五个滤波器安装在不同的温度阶段,通过滤波器之间的多次反射和吸收,降低红外/光/紫外光子到达探测器的概率。本文将介绍探测器组件的初步设计及其优化。
Diffuse X-ray Explorer is a proposed X-ray spectroscopic survey experiment for the China Space Station. Its detector assembly contains the transition edge sensor (TES) microcalorimeter and readout electronics based on the superconducting quantum interference device (SQUID) on the cold stage. The cold stage is thermally connected to the ADR stage, and a Kevlar suspension is used to stabilize and isolate it from the 4 K environment. TES and SQUID are both sensitive to the magnetic field, so a hybrid shielding structure consisting of an outer Cryoperm shield and an inner niobium shield is used to attenuate the magnetic field. In addition, IR/optical/UV photons can produce shot noise and thus degrade the energy resolution of the TES microcalorimeter. A blocking filter assembly is designed to minimize the effects. In it, five filters are mounted at different temperature stages, reducing the probability of IR/optical/UV photons reaching the detector through multiple reflections between filters and absorption. This paper will describe the preliminary design of the detector assembly and its optimization.
期刊介绍:
The Journal of Low Temperature Physics publishes original papers and review articles on all areas of low temperature physics and cryogenics, including theoretical and experimental contributions. Subject areas include: Quantum solids, liquids and gases; Superfluidity; Superconductivity; Condensed matter physics; Experimental techniques; The Journal encourages the submission of Rapid Communications and Special Issues.