{"title":"用于校准驻留声表面波声流体的查找表协议","authors":"Zixing Liu, Haixiang Zheng, Qinran Wei, Zeyi Wang, Yu Zhang, Dong Zhang, Xiasheng Guo","doi":"10.1007/s10404-024-02729-9","DOIUrl":null,"url":null,"abstract":"<div><p>The acoustic radiation force (ARF) acting on particles measures the performance of microfluidic devices driven by standing surface acoustic waves (SSAWs). However, existing ARF calibration techniques rely on image post-processing or additional equipment. This work proposes a look-up table method to determine the ARF by examining the particle acoustophoresis mode in discrete phase-modulated SSAW fields, where the phase difference between the two counter-propagating SAWs is changed at fixed time intervals. Theoretical analysis indicates that particles in a straight channel migrate laterally either in the “locked” mode or the “drift” mode, while mode switching can be observed when the interval reaches a critical value highly dependent on the ARF amplitude. A look-up table can then be established for a given SSAW device. By observing the particle acoustophoresis modes at different phase-changing intervals, the ARF amplitude can be obtained from the easily determined critical interval. The procedure is demonstrated experimentally in an SSAW acoustofluidic device and compared with the particle tracking protocol to verify the former’s effectiveness and demonstrate its operational simplicity. Inspired by the established theory, a method to improve the efficiency of particle acoustophoresis by optimizing the phase-modulating parameters is also proposed.</p></div>","PeriodicalId":706,"journal":{"name":"Microfluidics and Nanofluidics","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-05-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A look-up table protocol for calibrating standing SAW acoustofluidics\",\"authors\":\"Zixing Liu, Haixiang Zheng, Qinran Wei, Zeyi Wang, Yu Zhang, Dong Zhang, Xiasheng Guo\",\"doi\":\"10.1007/s10404-024-02729-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The acoustic radiation force (ARF) acting on particles measures the performance of microfluidic devices driven by standing surface acoustic waves (SSAWs). However, existing ARF calibration techniques rely on image post-processing or additional equipment. This work proposes a look-up table method to determine the ARF by examining the particle acoustophoresis mode in discrete phase-modulated SSAW fields, where the phase difference between the two counter-propagating SAWs is changed at fixed time intervals. Theoretical analysis indicates that particles in a straight channel migrate laterally either in the “locked” mode or the “drift” mode, while mode switching can be observed when the interval reaches a critical value highly dependent on the ARF amplitude. A look-up table can then be established for a given SSAW device. By observing the particle acoustophoresis modes at different phase-changing intervals, the ARF amplitude can be obtained from the easily determined critical interval. The procedure is demonstrated experimentally in an SSAW acoustofluidic device and compared with the particle tracking protocol to verify the former’s effectiveness and demonstrate its operational simplicity. Inspired by the established theory, a method to improve the efficiency of particle acoustophoresis by optimizing the phase-modulating parameters is also proposed.</p></div>\",\"PeriodicalId\":706,\"journal\":{\"name\":\"Microfluidics and Nanofluidics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-05-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microfluidics and Nanofluidics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s10404-024-02729-9\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microfluidics and Nanofluidics","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10404-024-02729-9","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
A look-up table protocol for calibrating standing SAW acoustofluidics
The acoustic radiation force (ARF) acting on particles measures the performance of microfluidic devices driven by standing surface acoustic waves (SSAWs). However, existing ARF calibration techniques rely on image post-processing or additional equipment. This work proposes a look-up table method to determine the ARF by examining the particle acoustophoresis mode in discrete phase-modulated SSAW fields, where the phase difference between the two counter-propagating SAWs is changed at fixed time intervals. Theoretical analysis indicates that particles in a straight channel migrate laterally either in the “locked” mode or the “drift” mode, while mode switching can be observed when the interval reaches a critical value highly dependent on the ARF amplitude. A look-up table can then be established for a given SSAW device. By observing the particle acoustophoresis modes at different phase-changing intervals, the ARF amplitude can be obtained from the easily determined critical interval. The procedure is demonstrated experimentally in an SSAW acoustofluidic device and compared with the particle tracking protocol to verify the former’s effectiveness and demonstrate its operational simplicity. Inspired by the established theory, a method to improve the efficiency of particle acoustophoresis by optimizing the phase-modulating parameters is also proposed.
期刊介绍:
Microfluidics and Nanofluidics is an international peer-reviewed journal that aims to publish papers in all aspects of microfluidics, nanofluidics and lab-on-a-chip science and technology. The objectives of the journal are to (1) provide an overview of the current state of the research and development in microfluidics, nanofluidics and lab-on-a-chip devices, (2) improve the fundamental understanding of microfluidic and nanofluidic phenomena, and (3) discuss applications of microfluidics, nanofluidics and lab-on-a-chip devices. Topics covered in this journal include:
1.000 Fundamental principles of micro- and nanoscale phenomena like,
flow, mass transport and reactions
3.000 Theoretical models and numerical simulation with experimental and/or analytical proof
4.000 Novel measurement & characterization technologies
5.000 Devices (actuators and sensors)
6.000 New unit-operations for dedicated microfluidic platforms
7.000 Lab-on-a-Chip applications
8.000 Microfabrication technologies and materials
Please note, Microfluidics and Nanofluidics does not publish manuscripts studying pure microscale heat transfer since there are many journals that cover this field of research (Journal of Heat Transfer, Journal of Heat and Mass Transfer, Journal of Heat and Fluid Flow, etc.).