利用时间分辨旋转血管造影术定量评估血流分流治疗对动脉瘤血流动力学的影响。

IF 1.5 4区 医学 Q4 CLINICAL NEUROLOGY
Jeremy C Peterson, Julie M DiNitto, Annette Birkhold, Nickalus Kahn, Christopher Nickele, Dan Hoit, Violiza Inoa, Lucas Elijovich, David Dornbos, Adam S Arthur
{"title":"利用时间分辨旋转血管造影术定量评估血流分流治疗对动脉瘤血流动力学的影响。","authors":"Jeremy C Peterson, Julie M DiNitto, Annette Birkhold, Nickalus Kahn, Christopher Nickele, Dan Hoit, Violiza Inoa, Lucas Elijovich, David Dornbos, Adam S Arthur","doi":"10.1177/15910199241252519","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>There have been immense advancements in the hardware and software of digital subtraction angiography systems over the last several years. These advancements continue to make progress toward the goals of offering better visualization and reducing radiation exposure. A newer advancement in this arena is presenting three-dimension data over time resulting in four-dimensional-digital subtracted angiography visualization. We have evaluated these protocols related to the evaluation of the treatment of intracranial aneurysms with pipeline flow diversion.</p><p><strong>Methods: </strong>Four-dimensional-digital subtracted angiography imaging was acquired on an Artis Q Biplane angiographic system (Siemens Healthcare AG, Forchheim, Germany). A six second four-dimensional-digital subtracted angiography protocol was performed pre and post flow diverter placement. Pre and post reconstructed images were sent through a dedicated prototype research workstation (Syngo X-Workplace; Siemens Healthineers AG) for further flow evaluation.</p><p><strong>Results: </strong>The treatment of an aneurysm with flow diversion led to a filling delay of 0.278 ± 0.422 s inside the aneurysms, whereas distal to the aneurysms the filling of the vessel segment occurred earlier post procedural (negative filling delay of -0.15 ± 0.31 s. The flow ratio inside the aneurysm decreased to 63.6 ± 23% of its pre-treatment value and distal to the aneurysm the flow remained substantially the same (flow ratio: 95.6 ± 0.29%). Data showed a relative filling delay of the aneurysm normalized to the distal vessel of 0.43 ± 0.36 s. The relative flow ratio of the aneurysm in comparison to the distal parent vessel was 72.2 ± 31%.</p><p><strong>Conclusions: </strong>Analysis of a four-dimensional-digital subtracted angiography acquisition allows assessment of the effects of flow diversion treatment on aneurysm hemodynamic parameters and shows a significant decrease in flow inside the aneurysm compared to the parent vessel distal to the aneurysm.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"15910199241252519"},"PeriodicalIF":1.5000,"publicationDate":"2024-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11571151/pdf/","citationCount":"0","resultStr":"{\"title\":\"Quantitative evaluation of the effects of flow diverter treatment on aneurysm hemodynamics using time-resolved rotational angiography.\",\"authors\":\"Jeremy C Peterson, Julie M DiNitto, Annette Birkhold, Nickalus Kahn, Christopher Nickele, Dan Hoit, Violiza Inoa, Lucas Elijovich, David Dornbos, Adam S Arthur\",\"doi\":\"10.1177/15910199241252519\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>There have been immense advancements in the hardware and software of digital subtraction angiography systems over the last several years. These advancements continue to make progress toward the goals of offering better visualization and reducing radiation exposure. A newer advancement in this arena is presenting three-dimension data over time resulting in four-dimensional-digital subtracted angiography visualization. We have evaluated these protocols related to the evaluation of the treatment of intracranial aneurysms with pipeline flow diversion.</p><p><strong>Methods: </strong>Four-dimensional-digital subtracted angiography imaging was acquired on an Artis Q Biplane angiographic system (Siemens Healthcare AG, Forchheim, Germany). A six second four-dimensional-digital subtracted angiography protocol was performed pre and post flow diverter placement. Pre and post reconstructed images were sent through a dedicated prototype research workstation (Syngo X-Workplace; Siemens Healthineers AG) for further flow evaluation.</p><p><strong>Results: </strong>The treatment of an aneurysm with flow diversion led to a filling delay of 0.278 ± 0.422 s inside the aneurysms, whereas distal to the aneurysms the filling of the vessel segment occurred earlier post procedural (negative filling delay of -0.15 ± 0.31 s. The flow ratio inside the aneurysm decreased to 63.6 ± 23% of its pre-treatment value and distal to the aneurysm the flow remained substantially the same (flow ratio: 95.6 ± 0.29%). Data showed a relative filling delay of the aneurysm normalized to the distal vessel of 0.43 ± 0.36 s. The relative flow ratio of the aneurysm in comparison to the distal parent vessel was 72.2 ± 31%.</p><p><strong>Conclusions: </strong>Analysis of a four-dimensional-digital subtracted angiography acquisition allows assessment of the effects of flow diversion treatment on aneurysm hemodynamic parameters and shows a significant decrease in flow inside the aneurysm compared to the parent vessel distal to the aneurysm.</p>\",\"PeriodicalId\":49174,\"journal\":{\"name\":\"Interventional Neuroradiology\",\"volume\":\" \",\"pages\":\"15910199241252519\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-05-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11571151/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Interventional Neuroradiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/15910199241252519\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199241252519","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:过去几年中,数字减影血管造影系统的硬件和软件都取得了巨大进步。这些进步不断朝着提供更好的可视化和减少辐射暴露的目标迈进。这一领域的最新进展是随着时间的推移显示三维数据,从而实现四维数字减影血管造影的可视化。我们对这些方案进行了评估,以评价用管道导流治疗颅内动脉瘤的效果:四维数字减影血管造影成像是在 Artis Q Biplane 血管造影系统(西门子医疗集团,德国福希海姆)上获得的。在血流分流器放置前后分别进行了六秒钟的四维数字减影血管造影。重建前和重建后的图像通过专用的原型研究工作站(Syngo X-Workplace; Siemens Healthineers AG)发送,以进行进一步的血流评估:动脉瘤内的充盈延迟为 0.278 ± 0.422 秒,而动脉瘤远端血管段的充盈在术后提前发生(负充盈延迟为 -0.15 ± 0.31 秒)。动脉瘤内的流量比降至治疗前的 63.6 ± 23%,而动脉瘤远端的流量基本保持不变(流量比:95.6 ± 0.29%)。数据显示,动脉瘤与远端血管的相对充盈延迟为 0.43 ± 0.36 秒:四维数字减影血管造影采集分析可评估血流分流治疗对动脉瘤血流动力学参数的影响,并显示与动脉瘤远端母血管相比,动脉瘤内血流明显减少。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Quantitative evaluation of the effects of flow diverter treatment on aneurysm hemodynamics using time-resolved rotational angiography.

Background: There have been immense advancements in the hardware and software of digital subtraction angiography systems over the last several years. These advancements continue to make progress toward the goals of offering better visualization and reducing radiation exposure. A newer advancement in this arena is presenting three-dimension data over time resulting in four-dimensional-digital subtracted angiography visualization. We have evaluated these protocols related to the evaluation of the treatment of intracranial aneurysms with pipeline flow diversion.

Methods: Four-dimensional-digital subtracted angiography imaging was acquired on an Artis Q Biplane angiographic system (Siemens Healthcare AG, Forchheim, Germany). A six second four-dimensional-digital subtracted angiography protocol was performed pre and post flow diverter placement. Pre and post reconstructed images were sent through a dedicated prototype research workstation (Syngo X-Workplace; Siemens Healthineers AG) for further flow evaluation.

Results: The treatment of an aneurysm with flow diversion led to a filling delay of 0.278 ± 0.422 s inside the aneurysms, whereas distal to the aneurysms the filling of the vessel segment occurred earlier post procedural (negative filling delay of -0.15 ± 0.31 s. The flow ratio inside the aneurysm decreased to 63.6 ± 23% of its pre-treatment value and distal to the aneurysm the flow remained substantially the same (flow ratio: 95.6 ± 0.29%). Data showed a relative filling delay of the aneurysm normalized to the distal vessel of 0.43 ± 0.36 s. The relative flow ratio of the aneurysm in comparison to the distal parent vessel was 72.2 ± 31%.

Conclusions: Analysis of a four-dimensional-digital subtracted angiography acquisition allows assessment of the effects of flow diversion treatment on aneurysm hemodynamic parameters and shows a significant decrease in flow inside the aneurysm compared to the parent vessel distal to the aneurysm.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Interventional Neuroradiology
Interventional Neuroradiology CLINICAL NEUROLOGY-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
3.60
自引率
11.80%
发文量
192
审稿时长
6-12 weeks
期刊介绍: Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信