Alicia Muñoz-Gallego, Martín Rodríguez-Salgado, Cristina López-López, José L Torres-Peña, Ana Ortueta-Olartecoechea, Javier De La Cruz, Pilar Tejada-Palacios
{"title":"儿童的视盘形态和眼间对称性。","authors":"Alicia Muñoz-Gallego, Martín Rodríguez-Salgado, Cristina López-López, José L Torres-Peña, Ana Ortueta-Olartecoechea, Javier De La Cruz, Pilar Tejada-Palacios","doi":"10.4103/sjopt.sjopt_229_22","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of the study was to obtain a pediatric reference database for optic disc parameters and interocular symmetry. To ascertain factors that modify these parameters (age, spherical equivalent [SE], and sex).</p><p><strong>Methods: </strong>This was a cross-sectional study. 90 patients aged 5-17 years fulfilled all the inclusion criteria. After a full examination including cycloplegic refraction, all patients underwent optical coherence tomography (OCT) of the papilla using the three-dimensional (3D) scan protocol of the Topcon 3D 2000 OCT device. We provide reference values for optic disc parameters in the pediatric population. We also retrieved interocular symmetry reference values for these parameters.</p><p><strong>Results: </strong>The multivariate regression analysis did not reveal variations in any of the optic disc parameters associated with age, sex, or SE (all <i>P</i> ≥ 0.126). The 95<sup>th</sup> percentile limit for absolute interocular differences for the cup-to-disc area ratio was 0.24. The multivariate regression analysis revealed the absence of a correlation between asymmetry of the optic disc parameters and age, sex, and the interocular difference in SE (all <i>P</i> ≥ 0.105).</p><p><strong>Conclusion: </strong>Pediatric reference databases for optic disc parameters and ranges of normality for interocular symmetry provide key diagnostic support in diseases that affect the optic nerve.</p>","PeriodicalId":46810,"journal":{"name":"Saudi Journal of Ophthalmology","volume":"38 1","pages":"47-52"},"PeriodicalIF":0.6000,"publicationDate":"2024-02-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11016995/pdf/","citationCount":"0","resultStr":"{\"title\":\"Optic disc morphology and interocular symmetry in children.\",\"authors\":\"Alicia Muñoz-Gallego, Martín Rodríguez-Salgado, Cristina López-López, José L Torres-Peña, Ana Ortueta-Olartecoechea, Javier De La Cruz, Pilar Tejada-Palacios\",\"doi\":\"10.4103/sjopt.sjopt_229_22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The purpose of the study was to obtain a pediatric reference database for optic disc parameters and interocular symmetry. To ascertain factors that modify these parameters (age, spherical equivalent [SE], and sex).</p><p><strong>Methods: </strong>This was a cross-sectional study. 90 patients aged 5-17 years fulfilled all the inclusion criteria. After a full examination including cycloplegic refraction, all patients underwent optical coherence tomography (OCT) of the papilla using the three-dimensional (3D) scan protocol of the Topcon 3D 2000 OCT device. We provide reference values for optic disc parameters in the pediatric population. We also retrieved interocular symmetry reference values for these parameters.</p><p><strong>Results: </strong>The multivariate regression analysis did not reveal variations in any of the optic disc parameters associated with age, sex, or SE (all <i>P</i> ≥ 0.126). The 95<sup>th</sup> percentile limit for absolute interocular differences for the cup-to-disc area ratio was 0.24. The multivariate regression analysis revealed the absence of a correlation between asymmetry of the optic disc parameters and age, sex, and the interocular difference in SE (all <i>P</i> ≥ 0.105).</p><p><strong>Conclusion: </strong>Pediatric reference databases for optic disc parameters and ranges of normality for interocular symmetry provide key diagnostic support in diseases that affect the optic nerve.</p>\",\"PeriodicalId\":46810,\"journal\":{\"name\":\"Saudi Journal of Ophthalmology\",\"volume\":\"38 1\",\"pages\":\"47-52\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2024-02-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11016995/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Saudi Journal of Ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/sjopt.sjopt_229_22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Saudi Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/sjopt.sjopt_229_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
摘要
目的:该研究的目的是获得一个儿科视盘参数和眼球间对称性的参考数据库。方法:这是一项横断面研究:这是一项横断面研究。90 名 5-17 岁的患者符合所有纳入标准。在进行了包括环镜屈光在内的全面检查后,所有患者都接受了乳头光学相干断层扫描(OCT),使用的是拓普康 3D 2000 OCT 设备的三维(3D)扫描方案。我们提供了儿童视盘参数的参考值。我们还检索了这些参数的眼球间对称性参考值:多变量回归分析未发现任何视盘参数的变化与年龄、性别或 SE 有关(所有 P 均≥ 0.126)。杯盘面积比的绝对眼间差异第 95 百分位数极限为 0.24。多变量回归分析显示,视盘参数的不对称与年龄、性别和SE的眼间差异之间没有相关性(所有P≥0.105):结论:儿科视盘参数参考数据库和眼间对称性正常范围为影响视神经的疾病提供了重要的诊断支持。
Optic disc morphology and interocular symmetry in children.
Purpose: The purpose of the study was to obtain a pediatric reference database for optic disc parameters and interocular symmetry. To ascertain factors that modify these parameters (age, spherical equivalent [SE], and sex).
Methods: This was a cross-sectional study. 90 patients aged 5-17 years fulfilled all the inclusion criteria. After a full examination including cycloplegic refraction, all patients underwent optical coherence tomography (OCT) of the papilla using the three-dimensional (3D) scan protocol of the Topcon 3D 2000 OCT device. We provide reference values for optic disc parameters in the pediatric population. We also retrieved interocular symmetry reference values for these parameters.
Results: The multivariate regression analysis did not reveal variations in any of the optic disc parameters associated with age, sex, or SE (all P ≥ 0.126). The 95th percentile limit for absolute interocular differences for the cup-to-disc area ratio was 0.24. The multivariate regression analysis revealed the absence of a correlation between asymmetry of the optic disc parameters and age, sex, and the interocular difference in SE (all P ≥ 0.105).
Conclusion: Pediatric reference databases for optic disc parameters and ranges of normality for interocular symmetry provide key diagnostic support in diseases that affect the optic nerve.
期刊介绍:
Saudi Journal of Ophthalmology is an English language, peer-reviewed scholarly publication in the area of ophthalmology. Saudi Journal of Ophthalmology publishes original papers, clinical studies, reviews and case reports. Saudi Journal of Ophthalmology is the official publication of the Saudi Ophthalmological Society and is published by King Saud University in collaboration with Elsevier and is edited by an international group of eminent researchers.