SpecReFlow:一种利用流引导视频完成镜面反射复原的算法。

IF 1.9 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Journal of Medical Imaging Pub Date : 2024-03-01 Epub Date: 2024-04-24 DOI:10.1117/1.JMI.11.2.024012
Haoli Yin, Rachel Eimen, Daniel Moyer, Audrey K Bowden
{"title":"SpecReFlow:一种利用流引导视频完成镜面反射复原的算法。","authors":"Haoli Yin, Rachel Eimen, Daniel Moyer, Audrey K Bowden","doi":"10.1117/1.JMI.11.2.024012","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Specular reflections (SRs) are highlight artifacts commonly found in endoscopy videos that can severely disrupt a surgeon's observation and judgment. Despite numerous attempts to restore SR, existing methods are inefficient and time consuming and can lead to false clinical interpretations. Therefore, we propose the first complete deep-learning solution, SpecReFlow, to detect and restore SR regions from endoscopy video with spatial and temporal coherence.</p><p><strong>Approach: </strong>SpecReFlow consists of three stages: (1) an image preprocessing stage to enhance contrast, (2) a detection stage to indicate where the SR region is present, and (3) a restoration stage in which we replace SR pixels with an accurate underlying tissue structure. Our restoration approach uses optical flow to seamlessly propagate color and structure from other frames of the endoscopy video.</p><p><strong>Results: </strong>Comprehensive quantitative and qualitative tests for each stage reveal that our SpecReFlow solution performs better than previous detection and restoration methods. Our detection stage achieves a Dice score of 82.8% and a sensitivity of 94.6%, and our restoration stage successfully incorporates temporal information with spatial information for more accurate restorations than existing techniques.</p><p><strong>Conclusions: </strong>SpecReFlow is a first-of-its-kind solution that combines temporal and spatial information for effective detection and restoration of SR regions, surpassing previous methods relying on single-frame spatial information. Future work will look to optimizing SpecReFlow for real-time applications. SpecReFlow is a software-only solution for restoring image content lost due to SR, making it readily deployable in existing clinical settings to improve endoscopy video quality for accurate diagnosis and treatment.</p>","PeriodicalId":47707,"journal":{"name":"Journal of Medical Imaging","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11042492/pdf/","citationCount":"0","resultStr":"{\"title\":\"SpecReFlow: an algorithm for specular reflection restoration using flow-guided video completion.\",\"authors\":\"Haoli Yin, Rachel Eimen, Daniel Moyer, Audrey K Bowden\",\"doi\":\"10.1117/1.JMI.11.2.024012\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Specular reflections (SRs) are highlight artifacts commonly found in endoscopy videos that can severely disrupt a surgeon's observation and judgment. Despite numerous attempts to restore SR, existing methods are inefficient and time consuming and can lead to false clinical interpretations. Therefore, we propose the first complete deep-learning solution, SpecReFlow, to detect and restore SR regions from endoscopy video with spatial and temporal coherence.</p><p><strong>Approach: </strong>SpecReFlow consists of three stages: (1) an image preprocessing stage to enhance contrast, (2) a detection stage to indicate where the SR region is present, and (3) a restoration stage in which we replace SR pixels with an accurate underlying tissue structure. Our restoration approach uses optical flow to seamlessly propagate color and structure from other frames of the endoscopy video.</p><p><strong>Results: </strong>Comprehensive quantitative and qualitative tests for each stage reveal that our SpecReFlow solution performs better than previous detection and restoration methods. Our detection stage achieves a Dice score of 82.8% and a sensitivity of 94.6%, and our restoration stage successfully incorporates temporal information with spatial information for more accurate restorations than existing techniques.</p><p><strong>Conclusions: </strong>SpecReFlow is a first-of-its-kind solution that combines temporal and spatial information for effective detection and restoration of SR regions, surpassing previous methods relying on single-frame spatial information. Future work will look to optimizing SpecReFlow for real-time applications. SpecReFlow is a software-only solution for restoring image content lost due to SR, making it readily deployable in existing clinical settings to improve endoscopy video quality for accurate diagnosis and treatment.</p>\",\"PeriodicalId\":47707,\"journal\":{\"name\":\"Journal of Medical Imaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11042492/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1117/1.JMI.11.2.024012\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/4/24 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1117/1.JMI.11.2.024012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/24 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:镜面反射(SR)是内窥镜视频中常见的高亮伪影,会严重干扰外科医生的观察和判断。尽管人们多次尝试还原镜面反射,但现有的方法效率低、耗时长,而且可能导致错误的临床解释。因此,我们提出了第一个完整的深度学习解决方案--SpecReFlow,用于从内窥镜视频中检测和还原具有时空一致性的 SR 区域:SpecReFlow包括三个阶段:(1) 增强对比度的图像预处理阶段;(2) 指出SR区域位置的检测阶段;(3) 用准确的底层组织结构替换SR像素的还原阶段。我们的还原方法采用光流技术,无缝传播内窥镜视频其他帧的颜色和结构:结果:对每个阶段进行的综合定量和定性测试表明,我们的 SpecReFlow 解决方案比以前的检测和修复方法性能更好。我们的检测阶段达到了 82.8% 的 Dice 分数和 94.6% 的灵敏度,而我们的修复阶段则成功地将时间信息与空间信息相结合,从而实现了比现有技术更精确的修复:SpecReFlow是一种首创的解决方案,它结合了时间和空间信息,可有效检测和修复SR区域,超越了以往依赖单帧空间信息的方法。未来的工作将着眼于为实时应用优化 SpecReFlow。SpecReFlow 是一种纯软件解决方案,可用于恢复因 SR 而丢失的图像内容,因此可随时部署到现有的临床环境中,以提高内窥镜视频质量,从而实现准确的诊断和治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
SpecReFlow: an algorithm for specular reflection restoration using flow-guided video completion.

Purpose: Specular reflections (SRs) are highlight artifacts commonly found in endoscopy videos that can severely disrupt a surgeon's observation and judgment. Despite numerous attempts to restore SR, existing methods are inefficient and time consuming and can lead to false clinical interpretations. Therefore, we propose the first complete deep-learning solution, SpecReFlow, to detect and restore SR regions from endoscopy video with spatial and temporal coherence.

Approach: SpecReFlow consists of three stages: (1) an image preprocessing stage to enhance contrast, (2) a detection stage to indicate where the SR region is present, and (3) a restoration stage in which we replace SR pixels with an accurate underlying tissue structure. Our restoration approach uses optical flow to seamlessly propagate color and structure from other frames of the endoscopy video.

Results: Comprehensive quantitative and qualitative tests for each stage reveal that our SpecReFlow solution performs better than previous detection and restoration methods. Our detection stage achieves a Dice score of 82.8% and a sensitivity of 94.6%, and our restoration stage successfully incorporates temporal information with spatial information for more accurate restorations than existing techniques.

Conclusions: SpecReFlow is a first-of-its-kind solution that combines temporal and spatial information for effective detection and restoration of SR regions, surpassing previous methods relying on single-frame spatial information. Future work will look to optimizing SpecReFlow for real-time applications. SpecReFlow is a software-only solution for restoring image content lost due to SR, making it readily deployable in existing clinical settings to improve endoscopy video quality for accurate diagnosis and treatment.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Medical Imaging
Journal of Medical Imaging RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.10
自引率
4.20%
发文量
0
期刊介绍: JMI covers fundamental and translational research, as well as applications, focused on medical imaging, which continue to yield physical and biomedical advancements in the early detection, diagnostics, and therapy of disease as well as in the understanding of normal. The scope of JMI includes: Imaging physics, Tomographic reconstruction algorithms (such as those in CT and MRI), Image processing and deep learning, Computer-aided diagnosis and quantitative image analysis, Visualization and modeling, Picture archiving and communications systems (PACS), Image perception and observer performance, Technology assessment, Ultrasonic imaging, Image-guided procedures, Digital pathology, Biomedical applications of biomedical imaging. JMI allows for the peer-reviewed communication and archiving of scientific developments, translational and clinical applications, reviews, and recommendations for the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信