{"title":"在单阶段种植过程中,术中立即加载夹板组件对支撑组织的影响。","authors":"Anatoliy Potapchuk, Vasyl Almashi, Yevhen Onipko, Csaba Hegedűs","doi":"10.36740/WLek202403114","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Aim: To study the specifics of the impact of immediate intraoperative loading with a splinting component on supporting tissues during a one-stage implantation protocol.</p><p><strong>Patients and methods: </strong>Materials and Methods: In the course of the study, orthopedic treatment was carried out for 55 patients aged 29 to 60 years. The following were performed: cone-beam computed tomography, software planning and intraoral scanning with an optical scanner, one-stage implantation protocol, assessment of implant stability with the Osstell ISQ device, microcirculation study in the peri-implant area using laser Doppler flowmetry (LDF).</p><p><strong>Results: </strong>Results: It was established that around loaded implants there is an increase in blood flow and vasomotor activity of the microcirculatory channel of the supporting tissues, an increase in the volume of bone tissue and an increase in torque, which is the optimal forecast for the acceleration of the pace of osseointegration.</p><p><strong>Conclusion: </strong>Conclusions: The use of a splinting component during immediate intraoperative functional masticatory load accelerates the dynamics of bone tissue remodeling processes around the implant, which is an optimal prediction of osseointegration rates in various dental implantation protocols and is consistent with high values of the implant stability coefficient.</p>","PeriodicalId":23643,"journal":{"name":"Wiadomosci lekarskie","volume":"77 3","pages":"462-471"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The influence of immediate intraoperative loading with a splinting component on supporting tissues during a one-stage implant.\",\"authors\":\"Anatoliy Potapchuk, Vasyl Almashi, Yevhen Onipko, Csaba Hegedűs\",\"doi\":\"10.36740/WLek202403114\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Aim: To study the specifics of the impact of immediate intraoperative loading with a splinting component on supporting tissues during a one-stage implantation protocol.</p><p><strong>Patients and methods: </strong>Materials and Methods: In the course of the study, orthopedic treatment was carried out for 55 patients aged 29 to 60 years. The following were performed: cone-beam computed tomography, software planning and intraoral scanning with an optical scanner, one-stage implantation protocol, assessment of implant stability with the Osstell ISQ device, microcirculation study in the peri-implant area using laser Doppler flowmetry (LDF).</p><p><strong>Results: </strong>Results: It was established that around loaded implants there is an increase in blood flow and vasomotor activity of the microcirculatory channel of the supporting tissues, an increase in the volume of bone tissue and an increase in torque, which is the optimal forecast for the acceleration of the pace of osseointegration.</p><p><strong>Conclusion: </strong>Conclusions: The use of a splinting component during immediate intraoperative functional masticatory load accelerates the dynamics of bone tissue remodeling processes around the implant, which is an optimal prediction of osseointegration rates in various dental implantation protocols and is consistent with high values of the implant stability coefficient.</p>\",\"PeriodicalId\":23643,\"journal\":{\"name\":\"Wiadomosci lekarskie\",\"volume\":\"77 3\",\"pages\":\"462-471\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Wiadomosci lekarskie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.36740/WLek202403114\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wiadomosci lekarskie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36740/WLek202403114","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
The influence of immediate intraoperative loading with a splinting component on supporting tissues during a one-stage implant.
Objective: Aim: To study the specifics of the impact of immediate intraoperative loading with a splinting component on supporting tissues during a one-stage implantation protocol.
Patients and methods: Materials and Methods: In the course of the study, orthopedic treatment was carried out for 55 patients aged 29 to 60 years. The following were performed: cone-beam computed tomography, software planning and intraoral scanning with an optical scanner, one-stage implantation protocol, assessment of implant stability with the Osstell ISQ device, microcirculation study in the peri-implant area using laser Doppler flowmetry (LDF).
Results: Results: It was established that around loaded implants there is an increase in blood flow and vasomotor activity of the microcirculatory channel of the supporting tissues, an increase in the volume of bone tissue and an increase in torque, which is the optimal forecast for the acceleration of the pace of osseointegration.
Conclusion: Conclusions: The use of a splinting component during immediate intraoperative functional masticatory load accelerates the dynamics of bone tissue remodeling processes around the implant, which is an optimal prediction of osseointegration rates in various dental implantation protocols and is consistent with high values of the implant stability coefficient.