利用时空光学相位技术实现光学薄膜的视觉性能。

IF 1.6 4区 医学 Q3 OPHTHALMOLOGY
Cathleen Fedtke, Daniel Tilia, Klaus Ehrmann, Jennie Diec, Karen Lahav-Yacouel, Darrin Falk, Ravi C Bakaraju
{"title":"利用时空光学相位技术实现光学薄膜的视觉性能。","authors":"Cathleen Fedtke, Daniel Tilia, Klaus Ehrmann, Jennie Diec, Karen Lahav-Yacouel, Darrin Falk, Ravi C Bakaraju","doi":"10.1097/OPX.0000000000002121","DOIUrl":null,"url":null,"abstract":"<p><strong>Significance: </strong>Spatio-Temporal Optical Phase technology utilizes film pairs containing optical elements applied to standard single-vision spectacle lenses. This technology provides a dynamic optical cue that may have efficacy in reducing the rate of myopia progression, but the visual performance of this technology is unknown.</p><p><strong>Purpose: </strong>This study aimed to assess the visual performance of film pairs containing optical elements (tests) and a film pair with no optical elements (control).</p><p><strong>Methods: </strong>In this randomized, single-masked, bilateral wear study, 42 participants aged 18 to 40 years wore four test designs (E, F-1, G, and F-2) and the control. Subjective data (subjective ratings [1 to 10 scale]: clarity of vision [far-away, intermediate, near] and vision [at night, while walking, overall satisfaction], and willingness to purchase [yes/no response]) were collected after 3 days. Visual acuity (VA)-based measures (monocular high/low-contrast VA [6 m], contrast sensitivity [6 m], and binocular high-contrast VA [6 m and 40 cm]) were collected at dispensing. Visual acuity-based measures were also collected while wearing spectacles with no film. Analyses were performed using linear mixed models and the χ2 test. Significance was set at 5%.</p><p><strong>Results: </strong>The control performed better than any test for all subjective ratings (mean differences, 1.6 to 3.1 units: p<0.001), willingness to purchase (p<0.001), and designs F-1 and F-2 for binocular high-contrast VA at 40 cm (p=0.001 and p=0.01, respectively). Clarity of vision was significantly worse with F-2 compared with F-1 and G (p<0.001 and p=0.02, respectively). There were no differences between tests for any other subjective rating (p>0.1), willingness to purchase (p=0.11), or any VA-based measure (p>0.08). There were no differences between control and spectacles with no film for any VA-based measure (p>0.08).</p><p><strong>Conclusions: </strong>All four test film pairs reduced visual performance compared with control to a degree comparable with other myopia management devices. There was no difference in visual performance between three of the four test film pairs.</p>","PeriodicalId":19649,"journal":{"name":"Optometry and Vision Science","volume":"101 4","pages":"195-203"},"PeriodicalIF":1.6000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Visual performance of optical films utilizing Spatio-Temporal Optical Phase technology.\",\"authors\":\"Cathleen Fedtke, Daniel Tilia, Klaus Ehrmann, Jennie Diec, Karen Lahav-Yacouel, Darrin Falk, Ravi C Bakaraju\",\"doi\":\"10.1097/OPX.0000000000002121\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Significance: </strong>Spatio-Temporal Optical Phase technology utilizes film pairs containing optical elements applied to standard single-vision spectacle lenses. This technology provides a dynamic optical cue that may have efficacy in reducing the rate of myopia progression, but the visual performance of this technology is unknown.</p><p><strong>Purpose: </strong>This study aimed to assess the visual performance of film pairs containing optical elements (tests) and a film pair with no optical elements (control).</p><p><strong>Methods: </strong>In this randomized, single-masked, bilateral wear study, 42 participants aged 18 to 40 years wore four test designs (E, F-1, G, and F-2) and the control. Subjective data (subjective ratings [1 to 10 scale]: clarity of vision [far-away, intermediate, near] and vision [at night, while walking, overall satisfaction], and willingness to purchase [yes/no response]) were collected after 3 days. Visual acuity (VA)-based measures (monocular high/low-contrast VA [6 m], contrast sensitivity [6 m], and binocular high-contrast VA [6 m and 40 cm]) were collected at dispensing. Visual acuity-based measures were also collected while wearing spectacles with no film. Analyses were performed using linear mixed models and the χ2 test. Significance was set at 5%.</p><p><strong>Results: </strong>The control performed better than any test for all subjective ratings (mean differences, 1.6 to 3.1 units: p<0.001), willingness to purchase (p<0.001), and designs F-1 and F-2 for binocular high-contrast VA at 40 cm (p=0.001 and p=0.01, respectively). Clarity of vision was significantly worse with F-2 compared with F-1 and G (p<0.001 and p=0.02, respectively). There were no differences between tests for any other subjective rating (p>0.1), willingness to purchase (p=0.11), or any VA-based measure (p>0.08). There were no differences between control and spectacles with no film for any VA-based measure (p>0.08).</p><p><strong>Conclusions: </strong>All four test film pairs reduced visual performance compared with control to a degree comparable with other myopia management devices. There was no difference in visual performance between three of the four test film pairs.</p>\",\"PeriodicalId\":19649,\"journal\":{\"name\":\"Optometry and Vision Science\",\"volume\":\"101 4\",\"pages\":\"195-203\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Optometry and Vision Science\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/OPX.0000000000002121\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Optometry and Vision Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/OPX.0000000000002121","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

意义重大:时空光学相位技术是将含有光学元件的胶片对应用于标准单光眼镜片。目的:本研究旨在评估含有光学元件的镜片对(测试)和不含光学元件的镜片对(对照)的视觉表现:在这项随机、单掩蔽、双侧配戴的研究中,42 名 18 至 40 岁的参与者配戴了四种测试设计(E、F-1、G 和 F-2)和对照组。3 天后收集主观数据(主观评分[1 至 10 分]:视力清晰度[远、中、近]和视力[夜间、行走时、总体满意度],以及购买意愿[是/否])。配镜时收集基于视力(VA)的测量值(单眼高/低对比度视力[6 米]、对比敏感度[6 米]和双眼高对比度视力[6 米和 40 厘米])。此外,还收集了佩戴无膜眼镜时的视力测量结果。采用线性混合模型和 χ2 检验进行分析。显著性设定为 5%:在所有主观评分(平均差异为 1.6 至 3.1 个单位:P0.1)、购买意愿(P=0.11)或任何基于视力的测量(P>0.08)方面,对照组的表现均优于任何测试。对照组和不贴膜的眼镜在任何基于视力的测量上都没有差异(p>0.08):结论:与对照组相比,所有四对测试片都降低了视觉表现,其程度与其他近视控制设备相当。四组测试片中的三组在视觉表现上没有差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Visual performance of optical films utilizing Spatio-Temporal Optical Phase technology.

Significance: Spatio-Temporal Optical Phase technology utilizes film pairs containing optical elements applied to standard single-vision spectacle lenses. This technology provides a dynamic optical cue that may have efficacy in reducing the rate of myopia progression, but the visual performance of this technology is unknown.

Purpose: This study aimed to assess the visual performance of film pairs containing optical elements (tests) and a film pair with no optical elements (control).

Methods: In this randomized, single-masked, bilateral wear study, 42 participants aged 18 to 40 years wore four test designs (E, F-1, G, and F-2) and the control. Subjective data (subjective ratings [1 to 10 scale]: clarity of vision [far-away, intermediate, near] and vision [at night, while walking, overall satisfaction], and willingness to purchase [yes/no response]) were collected after 3 days. Visual acuity (VA)-based measures (monocular high/low-contrast VA [6 m], contrast sensitivity [6 m], and binocular high-contrast VA [6 m and 40 cm]) were collected at dispensing. Visual acuity-based measures were also collected while wearing spectacles with no film. Analyses were performed using linear mixed models and the χ2 test. Significance was set at 5%.

Results: The control performed better than any test for all subjective ratings (mean differences, 1.6 to 3.1 units: p<0.001), willingness to purchase (p<0.001), and designs F-1 and F-2 for binocular high-contrast VA at 40 cm (p=0.001 and p=0.01, respectively). Clarity of vision was significantly worse with F-2 compared with F-1 and G (p<0.001 and p=0.02, respectively). There were no differences between tests for any other subjective rating (p>0.1), willingness to purchase (p=0.11), or any VA-based measure (p>0.08). There were no differences between control and spectacles with no film for any VA-based measure (p>0.08).

Conclusions: All four test film pairs reduced visual performance compared with control to a degree comparable with other myopia management devices. There was no difference in visual performance between three of the four test film pairs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Optometry and Vision Science
Optometry and Vision Science 医学-眼科学
CiteScore
2.80
自引率
7.10%
发文量
210
审稿时长
3-6 weeks
期刊介绍: Optometry and Vision Science is the monthly peer-reviewed scientific publication of the American Academy of Optometry, publishing original research since 1924. Optometry and Vision Science is an internationally recognized source for education and information on current discoveries in optometry, physiological optics, vision science, and related fields. The journal considers original contributions that advance clinical practice, vision science, and public health. Authors should remember that the journal reaches readers worldwide and their submissions should be relevant and of interest to a broad audience. Topical priorities include, but are not limited to: clinical and laboratory research, evidence-based reviews, contact lenses, ocular growth and refractive error development, eye movements, visual function and perception, biology of the eye and ocular disease, epidemiology and public health, biomedical optics and instrumentation, novel and important clinical observations and treatments, and optometric education.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信