{"title":"[利用可吸收骨合成剂(u-HA/PLLA 复合材料)对外伤性多发性肋骨骨折进行手术稳定]。","authors":"Hiroaki Harada, Koichi Akayama, Risa Kuboi, Satoshi Shibata","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In case that met several indication criteria with 4 or more rib fractures, we performed surgical stabilization of multiple fractured ribs using a plate and screw system( Super FIXORB MX) that was made of uncalcined hydroxyapatite (u-HA)/poly-L-lactic acid (PLLA) composite material with excellent bioactivity and absorbability. We report our clinical experience of 7 cases in which this device was used. Although there is still room for further consideration of the technique and the strength of the device itself, computed tomography( CT) images taken 9 months after surgery showed that the fixative device was almost assimilated with the bone at the fracture repair site in cases where fixation was successful.</p>","PeriodicalId":17841,"journal":{"name":"Kyobu geka. The Japanese journal of thoracic surgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Surgical Stabilization of Traumatic Multiple Rib Fractures Using Absorbable Osteosynthesis Agent(u-HA/PLLA Composite Material)].\",\"authors\":\"Hiroaki Harada, Koichi Akayama, Risa Kuboi, Satoshi Shibata\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In case that met several indication criteria with 4 or more rib fractures, we performed surgical stabilization of multiple fractured ribs using a plate and screw system( Super FIXORB MX) that was made of uncalcined hydroxyapatite (u-HA)/poly-L-lactic acid (PLLA) composite material with excellent bioactivity and absorbability. We report our clinical experience of 7 cases in which this device was used. Although there is still room for further consideration of the technique and the strength of the device itself, computed tomography( CT) images taken 9 months after surgery showed that the fixative device was almost assimilated with the bone at the fracture repair site in cases where fixation was successful.</p>\",\"PeriodicalId\":17841,\"journal\":{\"name\":\"Kyobu geka. The Japanese journal of thoracic surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Kyobu geka. The Japanese journal of thoracic surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kyobu geka. The Japanese journal of thoracic surgery","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
[Surgical Stabilization of Traumatic Multiple Rib Fractures Using Absorbable Osteosynthesis Agent(u-HA/PLLA Composite Material)].
In case that met several indication criteria with 4 or more rib fractures, we performed surgical stabilization of multiple fractured ribs using a plate and screw system( Super FIXORB MX) that was made of uncalcined hydroxyapatite (u-HA)/poly-L-lactic acid (PLLA) composite material with excellent bioactivity and absorbability. We report our clinical experience of 7 cases in which this device was used. Although there is still room for further consideration of the technique and the strength of the device itself, computed tomography( CT) images taken 9 months after surgery showed that the fixative device was almost assimilated with the bone at the fracture repair site in cases where fixation was successful.