根据 CLSI GP34-A 和 CLSI GP41-A6 对两种血清分离管进行临床化学分析的最终用户验证结果。

IF 1.3 4区 医学 Q4 MEDICINE, RESEARCH & EXPERIMENTAL
Sedat Abusoglu, Busra Ecer, Halil Guven, Ahmet Emre Yorulmaz, Muhittin Abdulkadir Serdar, Ali Unlu, Fikret Akyurek, Bahadir Ozturk, Gulsum Abusoglu
{"title":"根据 CLSI GP34-A 和 CLSI GP41-A6 对两种血清分离管进行临床化学分析的最终用户验证结果。","authors":"Sedat Abusoglu, Busra Ecer, Halil Guven, Ahmet Emre Yorulmaz, Muhittin Abdulkadir Serdar, Ali Unlu, Fikret Akyurek, Bahadir Ozturk, Gulsum Abusoglu","doi":"10.1080/00365513.2024.2344681","DOIUrl":null,"url":null,"abstract":"<p><p>Tube manufacturers use different composition of gels and blood clot activator formulations in serum tube production. Our aim was to investigate the within-tube (repeatability) and between-tube variation, concordance between comparison results of BD and VacuSEL tubes. Blood samples were collected from control subjects (n = 20) and patients (n = 30) in accordance with the CLSI GP41-A6 and CLSI GP34-A guidelines. Twenty-three clinical chemistry parameters were analysed via Roche Cobas C702 Chemistry Analyzer on T0 (0 hour) and T24 (24 hour). Mean differences % were compared with Wilcoxon matched pair test. Clinical significance was evaluated based on desirable bias according to total allowable error (TEa). VacuSEL tubes demonstrated acceptable performance for the results of 20 parameters with regards to desirable bias % limits. Lactate dehydrogenase (LD) [mean difference % (%95 confidence intervals (CI) values of BD and VacuSEL tubes at T0 [6.41% (4.80-8.01%)]; sodium (Na) and total protein (TP) at T24 [-0.27% (-0.46 to -0.07%) and -1.39% (-1.87 to -0.91), respectively] were over the desirable bias limits (LD: 4.3%, Na: 0.23% and TP: 1.36%, respectively) but not exceeding total biological variation CV % [Na: 0.5 (0.0-1.0) % and TP: 2.6 (2.3-2.7) %). %95 confidence intervals (CI) of T0 LD values overlap with within-subject biological variation % (CI) limits (LD: 5.2 (4.9-5.4) %). The differences between two tubes were not medically significant and necessarily conclusive. VacuSEL serum tubes presented comparable performance with BD serum tubes.</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":" ","pages":"183-192"},"PeriodicalIF":1.3000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"End-user verification results of two serum separator tubes for clinical chemistry analytes according to CLSI GP34-A and CLSI GP41-A6.\",\"authors\":\"Sedat Abusoglu, Busra Ecer, Halil Guven, Ahmet Emre Yorulmaz, Muhittin Abdulkadir Serdar, Ali Unlu, Fikret Akyurek, Bahadir Ozturk, Gulsum Abusoglu\",\"doi\":\"10.1080/00365513.2024.2344681\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Tube manufacturers use different composition of gels and blood clot activator formulations in serum tube production. Our aim was to investigate the within-tube (repeatability) and between-tube variation, concordance between comparison results of BD and VacuSEL tubes. Blood samples were collected from control subjects (n = 20) and patients (n = 30) in accordance with the CLSI GP41-A6 and CLSI GP34-A guidelines. Twenty-three clinical chemistry parameters were analysed via Roche Cobas C702 Chemistry Analyzer on T0 (0 hour) and T24 (24 hour). Mean differences % were compared with Wilcoxon matched pair test. Clinical significance was evaluated based on desirable bias according to total allowable error (TEa). VacuSEL tubes demonstrated acceptable performance for the results of 20 parameters with regards to desirable bias % limits. Lactate dehydrogenase (LD) [mean difference % (%95 confidence intervals (CI) values of BD and VacuSEL tubes at T0 [6.41% (4.80-8.01%)]; sodium (Na) and total protein (TP) at T24 [-0.27% (-0.46 to -0.07%) and -1.39% (-1.87 to -0.91), respectively] were over the desirable bias limits (LD: 4.3%, Na: 0.23% and TP: 1.36%, respectively) but not exceeding total biological variation CV % [Na: 0.5 (0.0-1.0) % and TP: 2.6 (2.3-2.7) %). %95 confidence intervals (CI) of T0 LD values overlap with within-subject biological variation % (CI) limits (LD: 5.2 (4.9-5.4) %). The differences between two tubes were not medically significant and necessarily conclusive. VacuSEL serum tubes presented comparable performance with BD serum tubes.</p>\",\"PeriodicalId\":21474,\"journal\":{\"name\":\"Scandinavian Journal of Clinical & Laboratory Investigation\",\"volume\":\" \",\"pages\":\"183-192\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scandinavian Journal of Clinical & Laboratory Investigation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/00365513.2024.2344681\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian Journal of Clinical & Laboratory Investigation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/00365513.2024.2344681","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/3 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

试管制造商在生产血清试管时使用不同的凝胶和血凝块活化剂配方。我们的目的是研究 BD 和 VacuSEL 血清试管的管内(重复性)和管间差异以及对比结果的一致性。根据 CLSI GP41-A6 和 CLSI GP34-A 指南,我们采集了对照组(20 人)和患者(30 人)的血样。在 T0(0 小时)和 T24(24 小时)期间,通过罗氏 Cobas C702 化学分析仪分析了 23 项临床化学参数。采用 Wilcoxon 配对检验比较平均差%。临床意义根据总允许误差(TEa)的理想偏差进行评估。VacuSEL 管在 20 个参数的结果中表现出了可接受的性能,达到了理想的偏差百分比限值。乳酸脱氢酶 (LD) [T0 时 BD 和 VacuSEL 管的平均差% (%95 置信区间 (CI) 值 [6.41% (4.80-8.01%)];T24 时钠 (Na) 和总蛋白 (TP) [-0.27% (-0.46 至 -0.07%) 和 -1.分别为-0.27%(-0.46 至-0.07%)和-1.39%(-1.87 至-0.91)]超过了理想偏差限(分别为 LD:4.3%、Na:0.23% 和 TP:1.36%),但未超过总生物变异 CV % [Na:0.5 (0.0-1.0) % 和 TP:2.6 (2.3-2.7) %]。T0 LD 值的 95%置信区间 (CI) 与受试者内生物变异% (CI) 限值重叠(LD:5.2 (4.9-5.4) %)。两种试管之间的差异不具有医学意义,也不一定是结论性的。VacuSEL 血清管与 BD 血清管的性能相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
End-user verification results of two serum separator tubes for clinical chemistry analytes according to CLSI GP34-A and CLSI GP41-A6.

Tube manufacturers use different composition of gels and blood clot activator formulations in serum tube production. Our aim was to investigate the within-tube (repeatability) and between-tube variation, concordance between comparison results of BD and VacuSEL tubes. Blood samples were collected from control subjects (n = 20) and patients (n = 30) in accordance with the CLSI GP41-A6 and CLSI GP34-A guidelines. Twenty-three clinical chemistry parameters were analysed via Roche Cobas C702 Chemistry Analyzer on T0 (0 hour) and T24 (24 hour). Mean differences % were compared with Wilcoxon matched pair test. Clinical significance was evaluated based on desirable bias according to total allowable error (TEa). VacuSEL tubes demonstrated acceptable performance for the results of 20 parameters with regards to desirable bias % limits. Lactate dehydrogenase (LD) [mean difference % (%95 confidence intervals (CI) values of BD and VacuSEL tubes at T0 [6.41% (4.80-8.01%)]; sodium (Na) and total protein (TP) at T24 [-0.27% (-0.46 to -0.07%) and -1.39% (-1.87 to -0.91), respectively] were over the desirable bias limits (LD: 4.3%, Na: 0.23% and TP: 1.36%, respectively) but not exceeding total biological variation CV % [Na: 0.5 (0.0-1.0) % and TP: 2.6 (2.3-2.7) %). %95 confidence intervals (CI) of T0 LD values overlap with within-subject biological variation % (CI) limits (LD: 5.2 (4.9-5.4) %). The differences between two tubes were not medically significant and necessarily conclusive. VacuSEL serum tubes presented comparable performance with BD serum tubes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.50
自引率
4.80%
发文量
85
审稿时长
4-8 weeks
期刊介绍: The Scandinavian Journal of Clinical and Laboratory Investigation is an international scientific journal covering clinically oriented biochemical and physiological research. Since the launch of the journal in 1949, it has been a forum for international laboratory medicine, closely related to, and edited by, The Scandinavian Society for Clinical Chemistry. The journal contains peer-reviewed articles, editorials, invited reviews, and short technical notes, as well as several supplements each year. Supplements consist of monographs, and symposium and congress reports covering subjects within clinical chemistry and clinical physiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信