{"title":"实施标准操作程序对减少伊朗血液中心血液损耗的影响。","authors":"Hayedeh Javadzadeh Shahshahani, Shahin Sharifi, Soheila Nasizadeh","doi":"10.34172/aim.2024.14","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Blood wastage leads to additional costs and reduced blood availability to patients. Above all is the moral issue of wasting donor gifts. This study aimed to determine the rate of blood wastage before and after implementing a new standard operating procedure (SOP) in Iran.</p><p><strong>Methods: </strong>In this interventional study, a SOP for wastage management was prepared and implemented in all blood centers throughout the country. Data were extracted from the integrated software of the Iranian Blood Transfusion Organization (IBTO). The wastage rate of blood components in the post-intervention years (2016-2017) was then compared with that in the pre-intervention years (2013-2015) using the Z test.</p><p><strong>Results: </strong>The overall wastage rate decreased by 36.86% (<i>P</i><0.001, 95% CI [36.84-36.88]) after the intervention. Red blood cell (RBC) wastage decreased from 2.6% to 2.5%, platelet wastage from 19.5% to 10.6% and plasma wastage from 15.5% to 7.3% (<i>P</i><0.001). The highest percentage of waste reduction pertained to plasma components, which decreased by 52.90% (<i>P</i><0.001, 95% CI [52.86-52.94]). Expiration was the most common cause of RBC and platelet wastage. The most common causes of plasma wastage were RBC contamination and rupture or leakage of the bags. The intervention resulted in a drop of over 250000 discarded components each year, equal to approximately thirty-six million dollars in savings.</p><p><strong>Conclusion: </strong>This intervention effectively reduced waste and increased efficiency. Ongoing blood wastage reviews, auditing, and receiving feedback from the central headquarters were powerful tools in following the compliance of blood centers. Further studies are recommended, especially concerning blood wastage in hospital blood banks and various wards.</p>","PeriodicalId":55469,"journal":{"name":"Archives of Iranian Medicine","volume":"27 2","pages":"89-95"},"PeriodicalIF":1.0000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11017257/pdf/","citationCount":"0","resultStr":"{\"title\":\"Impact of Implementing a Standard Operating Procedure to Reduce Blood Wastage in Blood Centers of Iran.\",\"authors\":\"Hayedeh Javadzadeh Shahshahani, Shahin Sharifi, Soheila Nasizadeh\",\"doi\":\"10.34172/aim.2024.14\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Blood wastage leads to additional costs and reduced blood availability to patients. Above all is the moral issue of wasting donor gifts. This study aimed to determine the rate of blood wastage before and after implementing a new standard operating procedure (SOP) in Iran.</p><p><strong>Methods: </strong>In this interventional study, a SOP for wastage management was prepared and implemented in all blood centers throughout the country. Data were extracted from the integrated software of the Iranian Blood Transfusion Organization (IBTO). The wastage rate of blood components in the post-intervention years (2016-2017) was then compared with that in the pre-intervention years (2013-2015) using the Z test.</p><p><strong>Results: </strong>The overall wastage rate decreased by 36.86% (<i>P</i><0.001, 95% CI [36.84-36.88]) after the intervention. Red blood cell (RBC) wastage decreased from 2.6% to 2.5%, platelet wastage from 19.5% to 10.6% and plasma wastage from 15.5% to 7.3% (<i>P</i><0.001). The highest percentage of waste reduction pertained to plasma components, which decreased by 52.90% (<i>P</i><0.001, 95% CI [52.86-52.94]). Expiration was the most common cause of RBC and platelet wastage. The most common causes of plasma wastage were RBC contamination and rupture or leakage of the bags. The intervention resulted in a drop of over 250000 discarded components each year, equal to approximately thirty-six million dollars in savings.</p><p><strong>Conclusion: </strong>This intervention effectively reduced waste and increased efficiency. Ongoing blood wastage reviews, auditing, and receiving feedback from the central headquarters were powerful tools in following the compliance of blood centers. Further studies are recommended, especially concerning blood wastage in hospital blood banks and various wards.</p>\",\"PeriodicalId\":55469,\"journal\":{\"name\":\"Archives of Iranian Medicine\",\"volume\":\"27 2\",\"pages\":\"89-95\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11017257/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives of Iranian Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.34172/aim.2024.14\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Iranian Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.34172/aim.2024.14","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
摘要
背景:血液浪费会导致额外的成本,并减少向患者提供血液的机会。最重要的是浪费捐献者的礼物这一道德问题。本研究旨在确定伊朗实施新标准操作程序(SOP)前后的血液浪费率:在这项干预性研究中,全国所有血液中心都制定并实施了浪费管理标准操作程序。数据来自伊朗输血组织(IBTO)的综合软件。然后使用 Z 检验将干预后年份(2016-2017 年)的血液成分损耗率与干预前年份(2013-2015 年)的血液成分损耗率进行比较:结果:总体浪费率降低了 36.86%(PPP):这一干预措施有效减少了浪费,提高了效率。持续的血液浪费审查、审计和接收来自中央总部的反馈是跟踪血液中心合规情况的有力工具。建议开展进一步研究,特别是有关医院血库和各病房血液浪费的研究。
Impact of Implementing a Standard Operating Procedure to Reduce Blood Wastage in Blood Centers of Iran.
Background: Blood wastage leads to additional costs and reduced blood availability to patients. Above all is the moral issue of wasting donor gifts. This study aimed to determine the rate of blood wastage before and after implementing a new standard operating procedure (SOP) in Iran.
Methods: In this interventional study, a SOP for wastage management was prepared and implemented in all blood centers throughout the country. Data were extracted from the integrated software of the Iranian Blood Transfusion Organization (IBTO). The wastage rate of blood components in the post-intervention years (2016-2017) was then compared with that in the pre-intervention years (2013-2015) using the Z test.
Results: The overall wastage rate decreased by 36.86% (P<0.001, 95% CI [36.84-36.88]) after the intervention. Red blood cell (RBC) wastage decreased from 2.6% to 2.5%, platelet wastage from 19.5% to 10.6% and plasma wastage from 15.5% to 7.3% (P<0.001). The highest percentage of waste reduction pertained to plasma components, which decreased by 52.90% (P<0.001, 95% CI [52.86-52.94]). Expiration was the most common cause of RBC and platelet wastage. The most common causes of plasma wastage were RBC contamination and rupture or leakage of the bags. The intervention resulted in a drop of over 250000 discarded components each year, equal to approximately thirty-six million dollars in savings.
Conclusion: This intervention effectively reduced waste and increased efficiency. Ongoing blood wastage reviews, auditing, and receiving feedback from the central headquarters were powerful tools in following the compliance of blood centers. Further studies are recommended, especially concerning blood wastage in hospital blood banks and various wards.
期刊介绍:
Aim and Scope: The Archives of Iranian Medicine (AIM) is a monthly peer-reviewed multidisciplinary medical publication. The journal welcomes contributions particularly relevant to the Middle-East region and publishes biomedical experiences and clinical investigations on prevalent diseases in the region as well as analyses of factors that may modulate the incidence, course, and management of diseases and pertinent medical problems. Manuscripts with didactic orientation and subjects exclusively of local interest will not be considered for publication.The 2016 Impact Factor of "Archives of Iranian Medicine" is 1.20.