为罗氏 cobas 仪器测量的体液化学分析物建立溶血、黄疸和脂血干扰限。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS
Darci R Block, Michael A Lasho, Leslie J Donato, Jeffrey W Meeusen
{"title":"为罗氏 cobas 仪器测量的体液化学分析物建立溶血、黄疸和脂血干扰限。","authors":"Darci R Block, Michael A Lasho, Leslie J Donato, Jeffrey W Meeusen","doi":"10.1093/ajcp/aqae040","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The aims of this study were to (1) establish the maximum allowable interference limits for hemolysis, lipemia, and icterus for chemistry analytes tested in body fluid samples and (2) assess the effectiveness of serial dilution to mitigate spectral interferences.</p><p><strong>Methods: </strong>Residual body fluids from clinically ordered testing were mixed (<10% by volume) with stock solutions of interferent (spiked) and compared with a control spiked with an equal volume of 0.9% saline. The analytes were measured on the Roche cobas c501 instrument. Difference and percentage difference were calculated and compared with allowable total error limits. A subset of samples were serially diluted with 0.9% saline. Mean (SD) difference and percentage difference were calculated.</p><p><strong>Results: </strong>The interference thresholds were lower than the package insert for lactate dehydrogenase, cholesterol, triglycerides, and total protein for hemolysis; amylase, cholesterol, and total protein for icterus; and albumin for lipemia. Only cholesterol and triglyceride results returned to baseline upon dilution of icteric samples.</p><p><strong>Conclusions: </strong>Interference thresholds in body fluids were lower than blood for 6 analytes. Diluting interferences that surpass these limits does not produce reliable results that are comparable to the baseline results before spiking in the interferent.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Establishing hemolysis, icterus, and lipemia interference limits for body fluid chemistry analytes measured on the Roche cobas instrument.\",\"authors\":\"Darci R Block, Michael A Lasho, Leslie J Donato, Jeffrey W Meeusen\",\"doi\":\"10.1093/ajcp/aqae040\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The aims of this study were to (1) establish the maximum allowable interference limits for hemolysis, lipemia, and icterus for chemistry analytes tested in body fluid samples and (2) assess the effectiveness of serial dilution to mitigate spectral interferences.</p><p><strong>Methods: </strong>Residual body fluids from clinically ordered testing were mixed (<10% by volume) with stock solutions of interferent (spiked) and compared with a control spiked with an equal volume of 0.9% saline. The analytes were measured on the Roche cobas c501 instrument. Difference and percentage difference were calculated and compared with allowable total error limits. A subset of samples were serially diluted with 0.9% saline. Mean (SD) difference and percentage difference were calculated.</p><p><strong>Results: </strong>The interference thresholds were lower than the package insert for lactate dehydrogenase, cholesterol, triglycerides, and total protein for hemolysis; amylase, cholesterol, and total protein for icterus; and albumin for lipemia. Only cholesterol and triglyceride results returned to baseline upon dilution of icteric samples.</p><p><strong>Conclusions: </strong>Interference thresholds in body fluids were lower than blood for 6 analytes. Diluting interferences that surpass these limits does not produce reliable results that are comparable to the baseline results before spiking in the interferent.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-10-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/ajcp/aqae040\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/ajcp/aqae040","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究的目的是:(1) 确定体液样本中检测的化学分析物溶血、脂血和黄疸的最大允许干扰限;(2) 评估连续稀释对减轻光谱干扰的有效性:方法:将临床检验中残留的体液混合在一起:乳酸脱氢酶、胆固醇、甘油三酯和总蛋白对溶血的干扰阈值低于包装说明书;淀粉酶、胆固醇和总蛋白对黄疸的干扰阈值低于包装说明书;白蛋白对脂血的干扰阈值低于包装说明书。稀释黄疸样本后,只有胆固醇和甘油三酯的结果恢复到基线:结论:体液中 6 种分析物的干扰阈值低于血液。结论:体液中 6 种分析物的干扰阈值低于血液中的干扰阈值,稀释超过这些阈值的干扰物不会产生可靠的结果,这些结果与添加干扰物之前的基线结果不相上下。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Establishing hemolysis, icterus, and lipemia interference limits for body fluid chemistry analytes measured on the Roche cobas instrument.

Objectives: The aims of this study were to (1) establish the maximum allowable interference limits for hemolysis, lipemia, and icterus for chemistry analytes tested in body fluid samples and (2) assess the effectiveness of serial dilution to mitigate spectral interferences.

Methods: Residual body fluids from clinically ordered testing were mixed (<10% by volume) with stock solutions of interferent (spiked) and compared with a control spiked with an equal volume of 0.9% saline. The analytes were measured on the Roche cobas c501 instrument. Difference and percentage difference were calculated and compared with allowable total error limits. A subset of samples were serially diluted with 0.9% saline. Mean (SD) difference and percentage difference were calculated.

Results: The interference thresholds were lower than the package insert for lactate dehydrogenase, cholesterol, triglycerides, and total protein for hemolysis; amylase, cholesterol, and total protein for icterus; and albumin for lipemia. Only cholesterol and triglyceride results returned to baseline upon dilution of icteric samples.

Conclusions: Interference thresholds in body fluids were lower than blood for 6 analytes. Diluting interferences that surpass these limits does not produce reliable results that are comparable to the baseline results before spiking in the interferent.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信