Rachael Y. Jablonski BDS, MFDS RCS(Ed), PhD , Taran Malhotra MSc, MIMPT , Daniel Shaw MIMPT , Trevor J. Coward PhD, MPhil, FIMPT, FETC , Farag Shuweihdi PhD , Chris Bojke BA(hons) MSc, PhD , Sue H. Pavitt BSc, PhD , Brian R. Nattress BChD, PhD, MRDRCS(Ed), FDSRCS(Ed), FDTF(Ed) , Andrew J. Keeling BSc, BDS, MFGDP, PhD
{"title":"使用三维可变形模型方法、传统计算机辅助设计方法和传统手工雕刻技术进行面部假体设计的真实性和可重复性比较。","authors":"Rachael Y. Jablonski BDS, MFDS RCS(Ed), PhD ,&nbsp;Taran Malhotra MSc, MIMPT ,&nbsp;Daniel Shaw MIMPT ,&nbsp;Trevor J. Coward PhD, MPhil, FIMPT, FETC ,&nbsp;Farag Shuweihdi PhD ,&nbsp;Chris Bojke BA(hons) MSc, PhD ,&nbsp;Sue H. Pavitt BSc, PhD ,&nbsp;Brian R. Nattress BChD, PhD, MRDRCS(Ed), FDSRCS(Ed), FDTF(Ed) ,&nbsp;Andrew J. Keeling BSc, BDS, MFGDP, PhD","doi":"10.1016/j.prosdent.2024.03.006","DOIUrl":null,"url":null,"abstract":"<div><h3>Statement of problem</h3><div>Manually sculpting a wax pattern of a facial prosthesis is a time-, skill-, and resource-intensive process. Computer-aided design (CAD) methods have been proposed as a substitute for manual sculpting, but these techniques can still require high technical or artistic abilities. Three-dimensional morphable models (3DMMs) could semi-automate facial prosthesis CAD. Systematic comparisons of different design approaches are needed.</div></div><div><h3>Purpose</h3><div>The purpose of this study was to compare the trueness and repeatability of replacing facial features with 3 methods of facial prosthesis design involving 3DMM, traditional CAD, and conventional manual sculpting techniques.</div></div><div><h3>Material and methods</h3><div>Fifteen participants without facial defects were scanned with a structured light scanner. The facial meshes were manipulated to generate artificial orbital, nasal, or combined defects. Three methods of facial prosthesis design were compared for the 15 participants and repeated to produce 5 of each design for 2 participants. For the 3DMM approach, the Leeds face model informed the designs in a statistically meaningful way. For the traditional CAD methods, designs were created by using mirroring techniques or from a nose model database. For the conventional manual sculpting techniques, wax patterns were manually created on 3D printed full face baseplates. For analysis, the unedited facial feature was the standard. The unsigned distance was calculated from each of the several thousand vertices on the unedited facial feature to the closest point on the external surface of the prosthesis prototype. The mean absolute error was calculated, and a Friedman test was performed (α=.05).</div></div><div><h3>Results</h3><div>The median mean absolute error was 1.13 mm for the 3DMM group, 1.54 mm for the traditional CAD group, and 1.49 mm for the manual sculpting group, with no statistically significant differences among groups (<em>P</em>=.549). Boxplots showed substantial differences in the distribution of mean absolute error among groups, with the 3DMM group showing the greatest consistency. The 3DMM approach produced repeat designs with the lowest coefficient of variation.</div></div><div><h3>Conclusions</h3><div>The 3DMM approach shows potential as a semi-automated method of CAD. Further clinical research is planned to explore the 3DMM approach in a feasibility trial.</div></div>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":"133 2","pages":"Pages 598-607"},"PeriodicalIF":4.3000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of trueness and repeatability of facial prosthesis design using a 3D morphable model approach, traditional computer-aided design methods, and conventional manual sculpting techniques\",\"authors\":\"Rachael Y. Jablonski BDS, MFDS RCS(Ed), PhD ,&nbsp;Taran Malhotra MSc, MIMPT ,&nbsp;Daniel Shaw MIMPT ,&nbsp;Trevor J. Coward PhD, MPhil, FIMPT, FETC ,&nbsp;Farag Shuweihdi PhD ,&nbsp;Chris Bojke BA(hons) MSc, PhD ,&nbsp;Sue H. Pavitt BSc, PhD ,&nbsp;Brian R. Nattress BChD, PhD, MRDRCS(Ed), FDSRCS(Ed), FDTF(Ed) ,&nbsp;Andrew J. Keeling BSc, BDS, MFGDP, PhD\",\"doi\":\"10.1016/j.prosdent.2024.03.006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Statement of problem</h3><div>Manually sculpting a wax pattern of a facial prosthesis is a time-, skill-, and resource-intensive process. Computer-aided design (CAD) methods have been proposed as a substitute for manual sculpting, but these techniques can still require high technical or artistic abilities. Three-dimensional morphable models (3DMMs) could semi-automate facial prosthesis CAD. Systematic comparisons of different design approaches are needed.</div></div><div><h3>Purpose</h3><div>The purpose of this study was to compare the trueness and repeatability of replacing facial features with 3 methods of facial prosthesis design involving 3DMM, traditional CAD, and conventional manual sculpting techniques.</div></div><div><h3>Material and methods</h3><div>Fifteen participants without facial defects were scanned with a structured light scanner. The facial meshes were manipulated to generate artificial orbital, nasal, or combined defects. Three methods of facial prosthesis design were compared for the 15 participants and repeated to produce 5 of each design for 2 participants. For the 3DMM approach, the Leeds face model informed the designs in a statistically meaningful way. For the traditional CAD methods, designs were created by using mirroring techniques or from a nose model database. For the conventional manual sculpting techniques, wax patterns were manually created on 3D printed full face baseplates. For analysis, the unedited facial feature was the standard. The unsigned distance was calculated from each of the several thousand vertices on the unedited facial feature to the closest point on the external surface of the prosthesis prototype. The mean absolute error was calculated, and a Friedman test was performed (α=.05).</div></div><div><h3>Results</h3><div>The median mean absolute error was 1.13 mm for the 3DMM group, 1.54 mm for the traditional CAD group, and 1.49 mm for the manual sculpting group, with no statistically significant differences among groups (<em>P</em>=.549). Boxplots showed substantial differences in the distribution of mean absolute error among groups, with the 3DMM group showing the greatest consistency. The 3DMM approach produced repeat designs with the lowest coefficient of variation.</div></div><div><h3>Conclusions</h3><div>The 3DMM approach shows potential as a semi-automated method of CAD. Further clinical research is planned to explore the 3DMM approach in a feasibility trial.</div></div>\",\"PeriodicalId\":16866,\"journal\":{\"name\":\"Journal of Prosthetic Dentistry\",\"volume\":\"133 2\",\"pages\":\"Pages 598-607\"},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2025-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Prosthetic Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0022391324001914\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022391324001914","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of trueness and repeatability of facial prosthesis design using a 3D morphable model approach, traditional computer-aided design methods, and conventional manual sculpting techniques

Statement of problem

Manually sculpting a wax pattern of a facial prosthesis is a time-, skill-, and resource-intensive process. Computer-aided design (CAD) methods have been proposed as a substitute for manual sculpting, but these techniques can still require high technical or artistic abilities. Three-dimensional morphable models (3DMMs) could semi-automate facial prosthesis CAD. Systematic comparisons of different design approaches are needed.

Purpose

The purpose of this study was to compare the trueness and repeatability of replacing facial features with 3 methods of facial prosthesis design involving 3DMM, traditional CAD, and conventional manual sculpting techniques.

Material and methods

Fifteen participants without facial defects were scanned with a structured light scanner. The facial meshes were manipulated to generate artificial orbital, nasal, or combined defects. Three methods of facial prosthesis design were compared for the 15 participants and repeated to produce 5 of each design for 2 participants. For the 3DMM approach, the Leeds face model informed the designs in a statistically meaningful way. For the traditional CAD methods, designs were created by using mirroring techniques or from a nose model database. For the conventional manual sculpting techniques, wax patterns were manually created on 3D printed full face baseplates. For analysis, the unedited facial feature was the standard. The unsigned distance was calculated from each of the several thousand vertices on the unedited facial feature to the closest point on the external surface of the prosthesis prototype. The mean absolute error was calculated, and a Friedman test was performed (α=.05).

Results

The median mean absolute error was 1.13 mm for the 3DMM group, 1.54 mm for the traditional CAD group, and 1.49 mm for the manual sculpting group, with no statistically significant differences among groups (P=.549). Boxplots showed substantial differences in the distribution of mean absolute error among groups, with the 3DMM group showing the greatest consistency. The 3DMM approach produced repeat designs with the lowest coefficient of variation.

Conclusions

The 3DMM approach shows potential as a semi-automated method of CAD. Further clinical research is planned to explore the 3DMM approach in a feasibility trial.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信