用于瞬态短路电流分析的三电平光伏逆变器状态空间平均模型

IF 2 4区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC
Shuai Yuan, Bing Wen, Jian-Ying Zhang, Zhimin Li
{"title":"用于瞬态短路电流分析的三电平光伏逆变器状态空间平均模型","authors":"Shuai Yuan,&nbsp;Bing Wen,&nbsp;Jian-Ying Zhang,&nbsp;Zhimin Li","doi":"10.1049/gtd2.13163","DOIUrl":null,"url":null,"abstract":"<p>This paper presents a state-space average model of a three-level photovoltaic (PV) inverter to understand short-circuit currents transient characteristics. Analytical solution of the model is also derived. The proposed model is validated with PV system controller hardware in-loop (HIL) test method. The errors between simulation and HIL tests results under various conditions are evaluated, testifying the validity of the proposed model. With the model and analytical solution, the decaying time constants of sub-transient and transient processes are derived, which shows that the time constants of a three-level PV inverter are not fixed and they vary with voltage dips. The analytical expression of short-circuit currents is also formulated. The findings from this study are essential to short-circuit current calculations of a power grid with large-scale PV plants, coordination of power system protections, and grid planning.</p>","PeriodicalId":13261,"journal":{"name":"Iet Generation Transmission & Distribution","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/gtd2.13163","citationCount":"0","resultStr":"{\"title\":\"A state-space average model of a three-level PV inverter for transient short-circuit currents analysis\",\"authors\":\"Shuai Yuan,&nbsp;Bing Wen,&nbsp;Jian-Ying Zhang,&nbsp;Zhimin Li\",\"doi\":\"10.1049/gtd2.13163\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>This paper presents a state-space average model of a three-level photovoltaic (PV) inverter to understand short-circuit currents transient characteristics. Analytical solution of the model is also derived. The proposed model is validated with PV system controller hardware in-loop (HIL) test method. The errors between simulation and HIL tests results under various conditions are evaluated, testifying the validity of the proposed model. With the model and analytical solution, the decaying time constants of sub-transient and transient processes are derived, which shows that the time constants of a three-level PV inverter are not fixed and they vary with voltage dips. The analytical expression of short-circuit currents is also formulated. The findings from this study are essential to short-circuit current calculations of a power grid with large-scale PV plants, coordination of power system protections, and grid planning.</p>\",\"PeriodicalId\":13261,\"journal\":{\"name\":\"Iet Generation Transmission & Distribution\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-04-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1049/gtd2.13163\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iet Generation Transmission & Distribution\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1049/gtd2.13163\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iet Generation Transmission & Distribution","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/gtd2.13163","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

本文提出了一个三电平光伏(PV)逆变器的状态空间平均模型,以了解短路电流的瞬态特性。同时还得出了该模型的解析解。提出的模型通过光伏系统控制器硬件在环(HIL)测试方法进行了验证。评估了各种条件下模拟和 HIL 测试结果之间的误差,证明了所提模型的有效性。通过模型和解析解,得出了亚瞬态和瞬态过程的衰减时间常数,这表明三电平光伏逆变器的时间常数并不是固定不变的,它们会随着电压骤降而变化。此外,还得出了短路电流的分析表达式。本研究的结论对于大规模光伏电站电网的短路电流计算、电力系统保护协调和电网规划至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

A state-space average model of a three-level PV inverter for transient short-circuit currents analysis

A state-space average model of a three-level PV inverter for transient short-circuit currents analysis

This paper presents a state-space average model of a three-level photovoltaic (PV) inverter to understand short-circuit currents transient characteristics. Analytical solution of the model is also derived. The proposed model is validated with PV system controller hardware in-loop (HIL) test method. The errors between simulation and HIL tests results under various conditions are evaluated, testifying the validity of the proposed model. With the model and analytical solution, the decaying time constants of sub-transient and transient processes are derived, which shows that the time constants of a three-level PV inverter are not fixed and they vary with voltage dips. The analytical expression of short-circuit currents is also formulated. The findings from this study are essential to short-circuit current calculations of a power grid with large-scale PV plants, coordination of power system protections, and grid planning.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Iet Generation Transmission & Distribution
Iet Generation Transmission & Distribution 工程技术-工程:电子与电气
CiteScore
6.10
自引率
12.00%
发文量
301
审稿时长
5.4 months
期刊介绍: IET Generation, Transmission & Distribution is intended as a forum for the publication and discussion of current practice and future developments in electric power generation, transmission and distribution. Practical papers in which examples of good present practice can be described and disseminated are particularly sought. Papers of high technical merit relying on mathematical arguments and computation will be considered, but authors are asked to relegate, as far as possible, the details of analysis to an appendix. The scope of IET Generation, Transmission & Distribution includes the following: Design of transmission and distribution systems Operation and control of power generation Power system management, planning and economics Power system operation, protection and control Power system measurement and modelling Computer applications and computational intelligence in power flexible AC or DC transmission systems Special Issues. Current Call for papers: Next Generation of Synchrophasor-based Power System Monitoring, Operation and Control - https://digital-library.theiet.org/files/IET_GTD_CFP_NGSPSMOC.pdf
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信